... supply of jet fighters and Centurions to Israel. Supply of air equipment to the Lebanese. 1955. FO 371/115558- ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
... distributions in chambers, while the performance of the supply-air openings for each chest determines the character of ... research on the air flow performance at the supply-air openings to improve the service performance, furthermore, to ... In this study, the airflow performance at the supply-air openings in a BCD-190W type household frost- ... adopted. The velocity distribution performance of typical rectangular supply-air openings in the refrigerator were measured. In addition, ... problem in flow rate and location design of supply-air openings were presented on the basis of the ...
Tópico(s): Aerodynamics and Fluid Dynamics Research
2009 - Elsevier BV | Applied Thermal Engineering
FROM OUR SPECIAL CORRESPONDENT, FROM OUR BOWLS CORRESPONDENT, FROM OUR RACING CORRESPONDENT, FROM OUR POLO CORRESPONDENT, FROM OUR CRICKET CORRESPONDENT, FROM OUR LAWN TENNIS CORRESPONDENT, FROM OUR YACHTING CORRESPONDENT, FROM OUR CORRESPONDENT, FROM A CORRESPONDENT, By CALLISTHENES, From Our Riga Correspondent, FROM OUR OWN CORRESPONDENT, FROM OUR DIPLOMATIC CORRESPONDENT, From Our Own Correspondent, From Our Correspondent, From Our Weather Correspondent, ALBERT HOWARD, LEONORA MARY ERVINE, R. C. CULLING CARR, From Our Paris Correspondent, From Our Shipping Correspondent, A correspondent, FROM OUR CIVIL SERVICE CORRESPONDENT, A. L. ROWSE, J. O. P. BLAND, D. M. MASON, COOPER RAWSON, TOM VAN OSS, JOHN C. LOCKWOOD, FROM OUR AGRICULTURAL CORRESPONDENT, FROM OUR KENNEL CORRESPONDENT, ALEC HOBSON, J. BENSKIN, C. W. WHATLEY., FROM OUR MOTORING CORRESPONDENT,
... Money Won, Pig Feeding The Importance Of Water Supply, Air Raids In China Great Fires At Shanghai Japan' ...
1937 - Gale Group | TDA
Shuangshuang Liang, Bozheng Li, Xue Tian, Yong Cheng, Chunhui Liao, Jianxin Zhang, Dong Liu,
... aimed to derive out the optimal ranges of supply air temperature and velocity so as to achieve both ... experimental chamber to examine the influence of warm supply air on indoor airflow pattern as well as indoor thermal environment. The results revealed that the supply air temperature and velocity affected thermal comfort and energy ... experiments, 42 cases with combinations of six different supply air velocities and seven different supply air temperatures were analyzed. The supply air temperatures and ...
Tópico(s): Wind and
2021 - Elsevier BV | Journal of Building Engineering
From Our Cricket Correspondent, From Our Athletics Correspondent, From Our Polo Correspondent, From Our Lawn Tennis Correspondent, From Our Rowing Correspondent, From Our Yachting Correspondent, From Our Racing Correspondent, From Our Own Correspondent, From Our Special Correspondent, From Our Correspondent, From Our Weather Correspondent, From Our Parliamentary Correspondent, From Our Diplomatic Correspondent, Leslie Housden., O. H. Gibbs-Smith, Archdeacon Of London; S. H. Phillimore, Arch Deacon Of Middlesex; C. E. Lambert, Archdeacon Of Hampstead. The Vestry, St. Martin'S Church, Ludgate Hill, E.C.4., Lucas Of Chilworth., Bledisloe., Portsmouth., Wakehurst, Prior., Yours, C., R. J. Martin. 1, Long Acre, W.C2, July 1., From Our Agricultural Correspondent, From Our Labour Correspondent, From Our Bridge Correspondent, From Our Dramatic Critic, From Our Music Critic, From A Manchester Correspondent,
... Impasse In Berlin Sunderland Flying-Boats Used For Air Supply, Lambeth Conference 330 Prelates At Service In St. ...
1948 - Gale Group | TDA
Ye Jin, Hua Qian, Jianchao Ma, Rong Zhou, Xiaohong Zheng,
... investigation is conducted to evaluate the effects of supply air velocity and angle on cutting off performance. Simulation ... ward, indicating satisfying performance of air curtains. Increasing supply air velocity is demonstrated to be conducive in forming full air curtains, whereas an excessively high supply air velocity may be of adverse effects by entraining exhaled flow. Besides, the supply air angle is also critical due to its coupling with supply air velocity. It is found that larger angle (0°- ...
Tópico(s): Food
2020 - Springer Science+Business Media | Building Simulation
From Our Labour Correspondent, From Our Correspondent, John Christie. Tapley Park, Instow, N. Devon., Limerick., From Our Own Correspondent, From Our Special Correspondent, From Our Weather Correspondent, A. P. Laurie., S. Muir Mackenzie. Portman Mansions, W.1., Douglas Jay. House Of Commons, Jan. 2., I Am, &C., Eric Macfadyen. 1-4, Great Tower Street, E.C.3., Fitzroy Maclean. House Of Commons, Jan. 1., By Our Aeronautical Correspondent, Ian Fraser. 9, Park Crescent, W.1., Alec Spoor, Public Relations Officer, , Ralph Hiscox. Veryan, Woodlands Road, West Byfleet, Jan. 1., By Our Music Critic, From Our Chess Correspondent, From A Correspondent, From Our Rackets Correspondent, From Our Racing Correspondent,
... Canadian Bacon To Cost More Hope Of Larger Supply, Air Power In The Assault Sir Trafford Leigh-Mallory ...
1947 - Gale Group | TDA
... and return air dampers are modulated to seek supply air temperature at its setpoint. The supply air temperature is typically set at 55 F (13 ° ... These facts provide an opportunity to use higher supply air temperature to reduce or eliminate mechanical cooling and terminal box reheat. On the contrary, a higher supply air temperature requires increased air flow as well as ... optimization question is formed, through which an optimal supply air temperature is identified to minimize total energy consumption. ...
Tópico(s): Building Energy and Comfort Optimization
2012 - Elsevier BV | Energy and Buildings
... Mr Roosevelt's Future Concentration on Danzig Organising Supply Air Raid Precautions The London & Lancashire Insurance Co. Ltd ...
1939 - Gale Group | The Economist
Wei Chen, Sheng Shang, Baolong Wang, Xianting Li, Yang Cao, Wenxing Shi,
... However, they waste a large amount of heat. Supply-air humidification provides a beneficial effect on the efficiency of heat recovery, but the effects of supply-air humidification on the thermal performance of combustion and ... experiment was conducted to investigate the effects of supply-air humidification on the thermal efficiency and emissions of a domestic boiler. The results indicated that supply-air humidification is beneficial for the improvement of the ... ratios were 1.3 and 1.1, respectively. Supply-air humidification had a significant effect on the condensing ...
Tópico(s): Thermochemical Biomass Conversion Processes
2019 - Elsevier BV | Energy and Buildings
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Suggests means of counting the supply of Soviet aircraft to the Syrian Air Force. 28 October - 3 November 1955. FO 371/ ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
Xiaoliang Shao, Shukui Liang, Xianting Li, Chao Liang, Shuai Yan,
... to improve environmental quality. The independent effect of supply air and contaminant source can be quantified using accessibility ... rooms with air recirculation devices, the effects of supply air and contaminant source cannot be described directly owing ... between steady contaminant distribution and each of independent supply air and contaminant sources with air recirculation, based on ... accessibility is defined to evaluate the effects of supply air and contaminant sources. The reliability of the proposed ...
Tópico(s): Indoor
2020 - Elsevier BV | Building and Environment
From Our Special Correspondent, From Our Rowing Correspondent, From Our Polo Correspondent, From Our Bowls Correspondent, From Our Lawn Tennis Correspondent, From Our Newmarket Correspondent, M. Mckenzie Wood, Matthew Anderson., L. S. Amery, Herbert Baker, Alfred C. Bossom, W. H. Bragg, Clarendon, Geo. Gibbard, Bernard E. Greenwell, Rob Holland-Martin, D. Lloyd George, Charles Ponsonby, E. J. Salisbury, Wolmer., A. C. Pearce, G. W. Bennett, K. Markau, Eric K. C. Hamilton, From Our Corresondent, From Our Correspondent, By Callisthenes, From Our Kennel Correspondent, From Our Ottawa Correspondent, From Our Own Correspondent, Our Aeronautical Correspondent, From Our Aeronautical Correspondent, From Our League Correspondent, From Our Diplomatic Correspondent, From Our Labour Correspondent, F. E. Bray, Leonard Stein, Allen Of Hurtwood, G. O. Stephenson., Decima Moore, Arthur R. Dolphin., By Philp Wills, From Our Fashion Correspondent, From A Correspondent, From Our Trinidad Correspondent,
... Kitchener Memorial 93 Scholarships Awarded, Royal Air Force Supply Of Air Observers. News in Brief. News: Three Counties Show ...
1938 - Gale Group | TDA
Fredrik Engdahl, Dennis Johansson,
... with a certain air flow at a certain supply air temperature. To minimize the system energy use, an optimal supply air temperature can be set dependent on the load, ... outdoor relative humidity. The theory for an optimal supply air temperature is presented and the heating, ventilation and ... conditioning (HVAC) energy use is calculated depending on supply air temperature control strategy, average U-value of the ... outdoor climates. The analyses show that controlling the supply air temperature optimally results in a significantly lower HVAC ...
Tópico(s): Refrigeration and
2003 - Elsevier BV | Energy and Buildings
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Quai d'Orsay refuses to supply Saudi Arabia with arms. 28 October - 3 November ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
Xia Song, Lun Zhang, Xiaosong Zhang,
... a heating source and a cooling source to supply air with the required temperature and humidity ratio. This ... results demonstrate that certain air states (fresh air, supply air, and return air) correspond to one particular solution ... temperatures of the heating and cooling sources, the supply air state is more influenced by the latter. At ... fixed temperature, a lower humidity ratio of the supply air demands a significant increase in the temperature of ... fixed humidity ratio, a lower temperature of the supply air requires lower temperatures for both sources, with a ...
Tópico(s): Solar Energy Systems and Technologies
2018 - Elsevier BV | Energy
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Conversation with King Hussein who complained of ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
S.A. Nada, Hesham M. El-Batsh, H.F. Elattar, Nor Merlisa Ali,
... Fluent 6.3), to understand the effects of supply air temperature, supply air velocity, space height and number of supply air diffusers on the performance of the air conditioning ... and energy saving than OHAD system, (iii) the supply air velocity and temperature, number of diffusers and height ... performance and thermal comfort obtained at 18 °C supply air temperature, 0.8 m/s supply air velocity and proper numbers and distributions of supply diffusers, (v) the percentage of energy saving due ...
Tópico(s): Infection Control and Ventilation
2016 - Elsevier BV | Journal of Building Engineering
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Conversation with M. Molotov on the question of the supply of Soviet arms to Egypt. 28 October - 3 ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
Gabriel Rojas, Rainer Pfluger, Wolfgang Feist,
... the living room as a pure overflow zone. Supply air nozzles are only installed in bedrooms. This way the supply air is used most effectively and supply air rates can be reduced while still maintaining good ... remained, if the fresh air coming from the supply air rooms mixes well enough with the living room ... for certain living room geometries (e.g. opposite supply-air-room and extract-air-room doors). The results ...
Tópico(s): Wind and
2015 - Elsevier BV | Energy and Buildings
... to Arab states. Letter from Major Durant on supply by France of 5,000 air/ground rockets to Israel. 1954. FO 371/110810- ...
1954 - Gale Group | ArchivesUnbound Arabi Israeli
Tao Lü, Xiaoshu Lü, Charles J. Kibert, Jari Puttonen,
... to-air heat recovery systems, as measured by supply air temperature efficiency, is an important energy saving strategy ... regulated by building codes. The high nonlinearity of supply air temperature efficiency with airflow rate in a run- ... heat recovery system makes the trend prediction of supply air temperature efficiency especially challenging for field measurement. This ... proposed that establishes a linear relationship between the supply air temperature increment across the supply air heat exchanger ...
Tópico(s): Adsorption and Cooling Systems
2015 - Elsevier BV | Energy and Buildings
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Syrian request for 16 Hunters together with ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
Wenhui Ji, Ping Wang, Tao Du, Zili Zhang,
... in the test chamber with WANV under different supply air conditions (air velocity and temperature). The shear-stress ... near-wall region is observed regardless of the supply air velocity. Furthermore, a correlation between the air velocity ... of WANV is significantly improved by decreasing the supply air temperature. Additionally, the impact of supply air conditions on the cooling performance is quantified using ... releasing effectiveness index, which suggests that the optimal supply air velocity is approximately 4 m/s in hot ...
Tópico(s): Wind and
2019 - Elsevier BV | Renewable Energy
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Possibility of establishing an arms credit for ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
A.E. Kabeel, Mohamed Abdelgaied, Ravishankar Sathyamurthy, T. Arunkumar,
... the other is utilized to pre-cool the supply air inlet to the room. The effects of the ... internal baffle as a pre-cooling unit, the supply air temperature reduced by 21% and the coefficient of ... inlet temperature from 25 °C to 45 °C, supply air temperature increases from 12.7 °C to 14. ... increases from 1.87 to 2.84, and supply air relative humidity increases from 76.7% to 77. ... inlet temperature from 70 °C to 110 °C, supply air temperature dropped from 15.9 °C to 10.9 °C, supply air relative humidity dropped from 82.7% to 71. ...
Tópico(s): Energy and Environmental Systems
2017 - Elsevier BV | Alexandria Engineering Journal
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Chart of present weapons holdings of Middle ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli
Dileep Kumar, Abdul Ghafoor Memon, Rizwan Ahmed Memon, Intizar Ali, Nataša Nord,
... energy and financial losses. The parameters such as supply air flow rate, supply air temperature, ambient air speed, and the convective heat ... increases with an increase in insulation thickness and supply air temperature, whereas it decreases with higher supply air flow rate. It is estimated that the minimum ... from the duct so affecting the conditions of supply air. Proper insulation thickness and operating parameters are important ...
Tópico(s): Refrigeration and
2017 - SAGE Publishing | Building Services Engineering Research and Technology
... answer to questions; Soviet arms for Syria: countering supply of Soviet aircraft to Syrian Air Force. Record of Mr Shuckburgh's meeting with ...
1955 - Gale Group | ArchivesUnbound Arabi Israeli