Computer-based Insulin Infusion Protocol Improves Glycemia Control over Manual Protocol
2007; Oxford University Press; Volume: 14; Issue: 3 Linguagem: Inglês
10.1197/jamia.m2292
ISSN1527-974X
AutoresJeffrey B. Boord, Mona Sharifi, Robert A. Greevy, Marie R. Griffin, V. K. Lee, Ty A. Webb, Michael May, Lemuel R. Waitman, Addison K. May, Randolph A. Miller,
Tópico(s)Intravenous Infusion Technology and Safety
ResumoObjective: Hyperglycemia worsens clinical outcomes in critically ill patients. Precise glycemia control using intravenous insulin improves outcomes. To determine if we could improve glycemia control over a previous paper-based, manual protocol, authors implemented, in a surgical intensive care unit (SICU), an intravenous insulin protocol integrated into a care provider order entry (CPOE) system.