Validated high-performance liquid chromatographic assay for the determination of promazine in human plasma

1998; Elsevier BV; Volume: 719; Issue: 1-2 Linguagem: Inglês

10.1016/s0378-4347(98)00262-x

ISSN

1872-812X

Autores

Véronique Larsimont, Jürgen Meins, Hiltrud Fieger-Büschges, Henning Blume,

Tópico(s)

Antibiotics Pharmacokinetics and Efficacy

Resumo

A high-performance liquid chromatographic method for the determination of promazine in human plasma is described. The assay involves a single-step liquid–liquid extraction using pentane–2-propanol (98:2, v/v). The analyte of interest and the internal standard chlorpromazine were separated on a Spherisorb CN column using a mobile phase of acetonitrile–50 mM ammonium acetate (9:1, v/v). Electrochemical detection was achieved using an applied potential of +750 mV. The assay was validated according to international requirements prior to application to a pharmacokinetic study and was found to be specific, accurate and precise with a linear range of 0.25–25 ng ml−1.

Referência(s)