Methods of measurement and sources of error using electrode systems
1968; Wiley; Volume: 23; Issue: 1 Linguagem: Inglês
10.1111/j.1365-2044.1968.tb00008.x
ISSN1365-2044
AutoresAlex Adams, J.O. MORGAN-HUGHES, M.K. SYKES,
Tópico(s)Cardiac, Anesthesia and Surgical Outcomes
ResumoAnaesthesiaVolume 23, Issue 1 p. 47-64 pH and blood gas analysisFree Access Methods of measurement and sources of error using electrode systems Part 2 MEASUREMENT OF CARBON DIOXIDE TENSION AND ACID-BASE A. P. Adams, A. P. Adams A. P. Adams, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Senior Registrar, Hammersmith Hospital, London W12 (in receipt of a grant from the Wellcome Trust); J. O. Morgan-Hughes, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Honorary Clinical Assistant, Department of Anaesthetics, St George's Hospital, London SW17 (in receipt of a grant from Bayer Products Co, now Senior Registrar, Hammersmith Hospital) and M. K. Sykes, MA, MB, FFARCS, Reader in Anaesthetics, Royal Postgraduate Medical School, London W12.Search for more papers by this authorJ. O. Morgan-Hughes, J. O. Morgan-Hughes A. P. Adams, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Senior Registrar, Hammersmith Hospital, London W12 (in receipt of a grant from the Wellcome Trust); J. O. Morgan-Hughes, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Honorary Clinical Assistant, Department of Anaesthetics, St George's Hospital, London SW17 (in receipt of a grant from Bayer Products Co, now Senior Registrar, Hammersmith Hospital) and M. K. Sykes, MA, MB, FFARCS, Reader in Anaesthetics, Royal Postgraduate Medical School, London W12.Search for more papers by this authorM. K. Sykes, M. K. Sykes A. P. Adams, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Senior Registrar, Hammersmith Hospital, London W12 (in receipt of a grant from the Wellcome Trust); J. O. Morgan-Hughes, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Honorary Clinical Assistant, Department of Anaesthetics, St George's Hospital, London SW17 (in receipt of a grant from Bayer Products Co, now Senior Registrar, Hammersmith Hospital) and M. K. Sykes, MA, MB, FFARCS, Reader in Anaesthetics, Royal Postgraduate Medical School, London W12.Search for more papers by this author A. P. Adams, A. P. Adams A. P. Adams, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Senior Registrar, Hammersmith Hospital, London W12 (in receipt of a grant from the Wellcome Trust); J. O. Morgan-Hughes, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Honorary Clinical Assistant, Department of Anaesthetics, St George's Hospital, London SW17 (in receipt of a grant from Bayer Products Co, now Senior Registrar, Hammersmith Hospital) and M. K. Sykes, MA, MB, FFARCS, Reader in Anaesthetics, Royal Postgraduate Medical School, London W12.Search for more papers by this authorJ. O. Morgan-Hughes, J. O. Morgan-Hughes A. P. Adams, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Senior Registrar, Hammersmith Hospital, London W12 (in receipt of a grant from the Wellcome Trust); J. O. Morgan-Hughes, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Honorary Clinical Assistant, Department of Anaesthetics, St George's Hospital, London SW17 (in receipt of a grant from Bayer Products Co, now Senior Registrar, Hammersmith Hospital) and M. K. Sykes, MA, MB, FFARCS, Reader in Anaesthetics, Royal Postgraduate Medical School, London W12.Search for more papers by this authorM. K. Sykes, M. K. Sykes A. P. Adams, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Senior Registrar, Hammersmith Hospital, London W12 (in receipt of a grant from the Wellcome Trust); J. O. Morgan-Hughes, MB, FFARCS, Research Fellow, Department of Anaesthetics, Royal Postgraduate Medical School, London W12 and Honorary Clinical Assistant, Department of Anaesthetics, St George's Hospital, London SW17 (in receipt of a grant from Bayer Products Co, now Senior Registrar, Hammersmith Hospital) and M. K. Sykes, MA, MB, FFARCS, Reader in Anaesthetics, Royal Postgraduate Medical School, London W12.Search for more papers by this author First published: March 1968 https://doi.org/10.1111/j.1365-2044.1968.tb00008.xCitations: 13AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL References 1 COLE, P. and LUMLEY, J. (1966). Arterial puncture. Br. med. J. 1, 1277. 2 STADIE, W. C. (1919). The oxygen of the arterial and venous blood in pneumonia and its relation to cyanosis. J. exp. med. Bact., 30, 215. 3 KETY, S. S. and SCHMIDT, C. F. (1946). The effect of active and passive hyperventilation on cerebral blood flow, cerebral oxygen consumption, cardiac output, and blood pressure of normal young men. J. clin. Invest. 25, 107. 4 SEVERINGHAUS, J. VV. (1960). Methods of measurement of blood and gas carbon dioxide during anesthesia. Anesthesiology, 21, 717. 5 YOSHIMURA, H. (1935). Effects of anticoagulants on the pH of the blood (Studies on blood pH estimated by the glass electrode method). J. Biochem., Tokyo, 22, 297. 6 SEVERINGHAUS, J. W., STUPFEL, M. and BRADLEY, A. F. (1956). Accuracy of blood pH and Pco2 determinations. J. appl. Physiol. 9. 189. 7 SIGGAARD-ANDERSEN, O. (1963). The acid-base status of the blood. Scand. J. clin. Lab. Invest. Suppl. 70. 8 SIGGAARD-ANDERSEN, O. (1961). Sampling and storing of blood for determination of acid-base status. Scand. J. clin. Lab. Invest. 13, 196. 9 LANGLANDS, J. H. M. and WALLACE, W. F. M. (1965). Small blood-samples from earlobe puncture. A substitute for arterial puncture. Lancet, 2, 315. 10 LILIENTHAL, J. L. and RILEY, R. L. (1946). On the estimation of arterial carbon dioxide from samples of cutaneous (capillary) blood. J. Lab. clin. Med. 31, 99. 11 GAMBINO, S. R. (1961). Mineral oil and carbon dioxide. Am. J. clin. Path. 35, 268. 12 GAMBINO, S. R. (1961). Collection of capillary blood for simultaneous determination of arterial pH, CO2 content, PCO2 and oxygen saturation. Am. J. clin. Path. 35, 175. 13 NUNN, J. F. (1962). Measurement of blood oxygen tension: Handling of samples. Br. J. Anaesth. 34, 621. 14 PAINE, E. G., BOUTWELL, J. H. and SOLOFF, L. A. (1961). The reliability of “arterialized” venous blood for measuring arterial pH and PCO2. Am. J. med. Sci. 242, 431. 15 HARRISON, E. M. and GALLOON, S. (1965). Venous blood as an alternative to arterial blood for the measurement of carbon dioxide tensions. Br. J. Anaesth. 37, 13. 16 RAISON, J. C. A. (1963). Choice of blood for acid-base studies. Lancet, 2, 1335. 17 BERGMAN, N. A., COLEMAN, A. J. and NUNN, B. F. (1963). Choice of blood for acid-base studies. Lancet, 2, 1335. 18 DOCRAT, K. and KENNY, S. (1965). The accuracy of capillary sampling for acid-base estimations. Br. J. Anaesth. 37, 840. 19 MAAS, A. H. J. and VAN HEIJST, A. N. P. (1961). The accuracy of the micro-determination of the Pco2 of blood from the ear-lobe. Clinica chim. Acta, 6, 34. 20 KNUDSEN, E. J. and HANSEN, P. (1962). Carbon dioxide tensions in non-arterialised capillary and arterial blood during anaesthesia. Acta anaesth. scand., 6, 29. 21 COOPER, E. A. and SMITH, H. (1961). Indirect estimation of arterial pco2. Anaesthesia, 16, 445. 22 SIGGAARD-ANDERSEN, O., ENGEL, K., JøRGENSEN, K. and ASTRUP, P. (1960). A micro method for determination of pH, carbon dioxide tension, base excess and standard bicarbonate in capillary blood. Scand. J. clin. Lab. Invest., 12, 172. 23 MAAS, A. J. H. and VAN HEHST, A. N. P. (1961). A comparison of the pH of arterial blood with arterialised blood from the ear-lobe with Astrup's micro glass electrode. Clinica chim. Acta, 6, 31. 24 SINGER, R. B., SHOHL, J. and BLUEMLE, D. B. (1955). Simultaneous determination of pH, CO2 content, and cell volume in 0.1 ml. aliquots of cutaneous blood: a modification of the Shock and Hastings technic. Clin. Chem. 1, 287. 25 LAUGHLIN, D. E., MCDONALD, J. S. and BEDELL, G. N. (1963). A micro technique for measurement of Po2 in “arterialized” ear lobe blood. Fed. Proc. Fedn Am. Socs exp. Biol., 22, 573. 26 SPOCK, A., HINTON, M. L. and ALBERTSON, T. H. (1966). A microtechnique for measurement of oxygen tension in capillary blood. J. Pediat. 68, 987. 27 LAUGHLIN, D. E., MCDONALD, J. S. and BEDELL, G.N. (1964). A micro technique for measurement of Po2 in “arterialized” earlobe blood. J. Lab. clin. Med. 64, 330. 28 ROBINSON, J. S. (1962). pH and PCO2 measurements in blood. Br. J. Anaesth. 34, 611. 29 NUNN, J. F. (1959). The accuracy of the measurement of blood PCO2 by the interpolation technique. In “ Symposium on pH and blood gas measurement”, p. 60. Ed. R. F. Woolmer. London : Churchill. 30 ASMUSSEN, E. and NIELSEN, M. (1961). The disappearance of oxygen from shed blood at body temperature. Scand. J. clin. Lab. Invest., 13, 297. 31 ELDRIDGE, F. and FRETWELL, L. K. (1965). Change in oxygen tension of shed blood at various temperatures. J. appl. Physiol. 20, 790. 32 RHODES, P. G. and MOSER, K. M. (1966). Sources of error in oxygen tension measurement. J. appl. Physiol. 21, 729. 33 LAMBERTSEN, C. J., BUNCE, P. L., DRABKIN, D. L. and SCHMIDT, C. F. (1952). Relationship of oxygen tension to hemoglobin oxygen saturation in the arterial blood of normal men. J. appl. Physiol. 4, 873. 34 KELMAN, G. R. and NUNN, J. F. (1966). Nomograms for correction of blood Po2, PCO2, pH, and base excess for time and temperature. J. appl. Physiol. 21, 1484. 35 CLARK, L. C (1956). Monitor and control of blood and tissue oxygen tensions. Trans. Amer. Soc. artif. internal Organs, 2, 41. 36 BISHOP, J. M. (1960). Measurement of blood oxygen tension. Proc. R. Soc. Med. 53, 177. 37 SEVERINGHAUS, J. W. and BRADLEY, A. F. (1958). Electrodes for blood pO2 and pCO2 determination J. appl. Physiol. 13, 515. 38 SEVERINGHAUS, J. W. (1962). Electrodes for blood and gas Pco2, Po2 and blood pH. Acta anaesth. scand. Suppl. 11, 206. 39 SEVERINGHAUS, J. W. (1959). Recent developments in blood O2 and CO2 electrodes. In “ Symposium on pH and blood-gas measurement”, p. 126. Ed. R. F. Woolmer. London : Churchill. 40 SPROULE, B. J., MILLER, W. F., CUSHING, I. E. and CHAPMAN, C. B. (1957). An improved polarographic method for measuring oxygen tension in whole blood. J. appl. Physiol. 11, 365. 41 LAVER, M. B. and SEIFEN, A. (1965). Measurement of blood oxygen tension in anesthesia. Anesthesiology, 26, 73. 42 Scientific Tables, 6th Ed. p. 297. Manchester : Geigy Pharmaceutical Co. 43 NUNN, J. F., BERGMAN, N. A., COLEMAN, A. J. and CASSELLE, D. C (1964). Evaluation of the Servomex paramagnetic analyzer. Br. J. Anaesth. 36, 666. 44 HEDLEY-WHYTE, J., RADFORD, E. P. and LAVER, M. B. (1965). Nomogram for temperature correction or electrode calibration during Po2 measurements. J. appl. Physiol. 20, 785. 45 HEDLEY-WHYTE, J. and LAVER, M. B. (1964). O2 solubility in blood and temperature correction factors for Po2. J. appl. Physiol. 19, 901. 46 NUNN, J. F., BERGMAN, N. A., BUNATYAN, A. and COLEMAN, A. J. (1965). Temperature coefficients for Pco2 and Po2 of blood in vitro. J. appl. Physiol. 20, 23. 47 SILVER, I. A. (1963). A simple micro-cathode for measuring Po2 in gas or fluid. Med. Electron, biol. Engng 1, 547. 48 POLGAR, G. and FORSTER, R.E. (1960). Measurement of oxygen tension in unstirred blood with a platinum electrode. J. appl. Physiol. 15, 706. 49 JUNG, R. C, BALCHUM, O. J. and MASSEY, F. J. (1966). The accuracy of venous and capillary blood for the prediction of arterial pH, PCO2 and PO2 measurements. Amer. J. clin. Path. 45, 129. 50 MORAN, F., KETTEL, L. J. and CUGELL, D. W. (1966). Measurement of blood Po2 with the microcathode electrode. J. appl. Physiol. 21, 725. 51 ADAMS, A. P. and MORGAN-HUGHES, J. O. (1967). Determination of the blood-gas factor of the oxygen electrode using a new tonometer. Br. J. Anaesth. 39, 107. 52 ADAMS, A. P. and MORGAN-HUGHES, J. O. (1966). Unpublished observations. 53 RAVIN, M. B. and BRISCOE, W. A. (1964). Blood-gas transfer, hemolysis, and diffusing capacity in a bubble tonometer. J appl. Physiol., 19, 784. 54 BRADLEY, A. F., STUPFEL, M. and SEVERINGHAUS, J. W. (1956). Effect of temperature on Pco2 and PO2 of blood in vitro. J. appl. Physiol. 9, 201. 55 NUNN, J. F. (1966). Oxygen tension temperature factor. Anesthesiology, 27, 204. 56 MYERS, A. W., STANNETT, V. and SZWARC (1959). The permeability of polypropylene to gases and vapours. J. Polym. Sci. 35, 285. 57 BATTENBERG, L. D. (1965). A membrane mounting aid for use with Beckman PO2 electrodes. Anesthesiology, 26, 685. 58 GOLD, V. (1958). Ph measurements. Their theory and practice. London : Methuen. 59 BATES, R. G. (1960). Electrometric pH determinations. Chimia, 14, 111. 60 BATES, R. G. (1954). Electrometric pH determinations. Theory and Practice. London : Chapman and Hall. 61 BATES, R. G. (1964). Determination of pH. Theory and Practice. New York : John Wiley. 62 LENFANT, C. and AUCUTT, C. (1965). Oxygen uptake and change in carbon dioxide tension in human blood stored at 37°C. J. appl. Physiol., 20, 503. 63 WOOLMER, R. (1962). The measurement of pH and Pco2. In Modern Trends in Anaesthesia: Aspects of hydrogen ion regulation and biochemistry in anaesthesia, p. 31, Ed. F. T. Evans and T. C. Gray. London : Butterworths. 64 SEMPLE, S. J. G. (1961). Observed pH differences of blood and plasma with different bridge solutions. J. appl. Physiol., 16, 576. 65 SANZ, M. C. (1957). Ultramicro methods and standardization of equipment. Clin. Client., 3, 406. 66 ASTRUP, P. (1959). Ultra-micro-method for determining pH, PCO2 and standard bicarbonate in capillary blood. In Symposium on pH and blood gas measurement, p. 81. Ed. R. F. Woolmer. London : Churchill. 67 BURTON, G. W. (1964). Personal Communication. 68 BREMS, N. (1962). Measurements of pH. Electrodes and pertinent apparatus. Acta anaesth. scand. Suppl. 11, 199. 69 ROBINSON, J. S. and PIMBLETT, I. (1962). The electrometric determination of blood pH. Br. J. Anaesth., 34, 31. 70 ANSTALL, H. B., GROVE-RASMUSSEN, M. and SHAW, R. S. (1961). Optimal conditions for storage of fresh frozen plasma. Transfusion, Philad., 1, 87. 71 MATTOCK, G. (1957). The accurate measurement of pH. Part 2. Sources of experimental error in pH measurement. Lab. Pract., 6, 521. 72 WRIGHT, M. P. (1959). pH measurements with the glass electrode. In Symposium on pHand bloodgas measurement, p. 5, Ed. R. F. Woolmer. London : Churchill. 73 GAMBINO, S. R. (1959). Heparinized vacuum tubes for determination of plasma pH, plasma CO2 content, and blood oxygen saturation. Amer. J. clin. Path., 32, 285. 74 SIGGAARD-ANDERSEN, O. (1961). Factors affecting the liquid-junction potential in electrometric blood pH measurement. Scand. J. clin. Lab. Invest., 13, 205. 75 JENNY, H., NIELSEN, T. R., COLEMAN, N. T. and WILLIAMS, D. E. (1950). Concerning the measurement of pH, ion activities, and membrane potentials in colloidal systems. Science, N.Y., 112, 164. 76 MATTOCK, G. (1959). Electrochemical aspects of blood pH measurements. In Symposium on pH and blood gas measurement, p. 19. Ed. R. F. Woolmer. London : Churchill. 77 NORMAN, J., LEDSOME, J. R. and LINDEN, R. J. (1965). A system for the measurement of respiratory and acid-base parameters in blood, Br. J. Anaesth., 37, 466. 78 HUBBARD, D., HAMILTON, E. H. and FINN, A. N. (1939). Effect of the solubility of glass on the behaviour of the glass electrode. J. Res. natn. Bur. Stand., 22, 339. 79 BATES, R. G. (1948). Definitions of pH scales. Chem. Rev., 42, 1. 80 BATES, R. G. (1962). Revised standard values for pH measurements from 0 to 95°C. J. Res. natn. Bur. Stand. 66A, 179. 81 Statement on Acid-Base Terminology. Report of ad hoc Committee of New York Academy of Sciences Conference, (November 23 and 24, 1964). (1966). Anesthesiology, 27, 7. 82 SEMPLE, S. J. G., MATTOCK, G. and UNCLES, R. (1962). A buffer standard for blood pH measurements. J. biol. Chem. 237, 963. 83 WYKN, V. and LUDBROOK, J. (1957). A method of measuring the pH of body-fluids. Lancet, i, 1068. 84 ROSENTHAL, T. B. (1948). The effect of temperature on the pH of blood and plasma in vitro. J biol. Chem., 173, 25. 85 GREENBURG, A. G. and MOULDER, P. V. (1965). Temperature coefficients for PC02 and pH in whole blood. Archs Surg., Chicago, 91, 867. 86 AUSTIN, W. H., LACOMBE, E. H. and RAND, P. W. (1964). pH-temperature conversion factors and pCO2 factors for hypothermia. J. appl. Physiol. 19, 893. 87 ADAMSONS, K., DANIEL, S. S., GANDY, G. and JAMES, L. S. (1964). Influence of temperature on blood pH of the human adult and newborn. J. appl. Physiol. 19, 897. 88 BURTON, G. W. (1965). Effects of the acid-base state upon the temperature coefficient of pH of blood. Br. J. Anaesth. 37, 89. 89 SEVERINGHAUS, J. W. (1966). Blood gas calculator. J. appl. Physiol. 21, 1108. 90 KELMAN, G. R., COLEMAN, A. J. and NUNN, J. F. (1966). Evaluation of a microtono-meter used with a capillary glass pH electrode. J. appl. Physiol. 21, 1103. 91 Report of the ad hoc committee on acid-base terminology of the New York Academy of Sciences Conference; current concepts of acid-base measurement. (1966). Ann. N. Y. Acad. Sci., 133, 251. 92 BACH, J. R. (1963). The measurement of blood pH with the Radiometer capillary blood electrodes. Copenhagen : Radiometer S.A. 93 ASTRUP, P., JBRGENSEN, K., ANDERSEN, O. S. and ENGEL, K. (1960). The acid-base metabolism. A new approach. Lancet, i, 1035. 94 ASTRUP, P. (1961). A new approach to acid-base metabolism. Clin. Chem. 7, 1. 95 NEEMATALLAH, F. A., CHAPMAN, L. M. and SYKES, M. K. (1963). Possible sources of error in the determination of arterial carbon dioxide tension by an interpolation technique. Br. J. Anaesth., 35, 338. 96 SIGGAARD-ANDERSEN, O. and ENGEL, K. (1960). A new acid-base nomogram. An improved method for the calculation of the relevant blood acid-base data. Scand. J. clin. Lab. Invest. 12, 177. 97 SIGGAARD-ANDERSEN, O. (1962). The pH-log pCO2 blood acid-base nomogram revised. Scand. J. clin. Lab. Invest., 14, 598. 98 SIGGAARD-ANDERSEN, O. (1963). Blood acid-base alignment nomogram. Scand. J.clin. Lab. Invest., 15, 211. 99 SEVERINGHAUS, J. W., STUPFEL, M. and BRADLEY, A. F. (1956). Variations of serum carbonic acid pK' with pH and temperature. J. appl. Physiol. 9, 197. 100 SIGGAARD-ANDERSEN, O. (1962). The first dissociation exponent of carbonic acid as a function of pH. Scand. J. clin. Lab. Invest., 14, 587. 101 AUSTTN, W. H., LACOMBE, E., RAND, P. W. and CHATTERJEE, M. (1963). Solubility of carbon dioxide in serum from 15° to 38°C. J. appl. Physiol, 18, 301. 102 SCHWARTZ, W. B. and RELMAN, A. S. (1963). A critique of the parameters used in the evaluation of acid-base disorders. New Engl. J. Med., 268, 1382. 103 BRACKETT, N. C, COHEN, J. J. and SCHWARTZ, W. B. (1965). Carbon dioxide titration curve of normal man. Effect of increasing degrees of acute hypercapnia on acid-base equilibrium. New Engl. J. Med., 272, 6. 104 COHEN, J.J., BRACKETT, N. C. and SCHWARTZ, W. B. (1964). The nature of the carbon dioxide titration curve in the normal dog. J. clin. Invest., 43, 777. 105 IOMLIN, P. J., SCHLOBOHM, R. M., CARSEN, S. A. A. and MORRIS, L.E. (1967). The in vivo pH-Pco2 nomogram in the dog. Anesthesiology (In Press). 106 BUNKER, J. P. (1965). The great trans-Atlantic acid-base debate. Anesthesiology, 26, 591. 107 SIGGAARD-ANDERSEN, O. and ENGEL, K. (1966). Acid-base debate. Anesthesiology, 27, 202. 108 BUNKER, J. P. (1966). Acid-base debate. Anesthesiology, 27, 203. 109 STOW, R. W., BAER, R. F. and RANDALL, B. F. (1957). Rapid measurement of the tension of carbon dioxide in blood. Archs phys. Med. Rehabil., 38, 646. 110 SNELL, F. M. (1960). Electrometric determination of CO2 and bicarbonate ion. J. appl. Physiol., 15, 729. 111 OGILVIE, R. R. and HOWIE, G. F. A. (1965). Effect of gaseous anaesthesia on blood carbon dioxide measurements. J. clin. Path., 18, 364. 112 LUNN, J. N. and MAPLESON, W. W. (1963). The Severinghaus PCO2 electrode: A theoretical and experimental assessment. Br. J. Anaesth., 35, 666. 113 JØRGENSEN, K. and ASTRUP, P. (1957). Standard bicarbonate, its clinical significance, and a new method for its determination. Scand. J. clin. Lab. Invest., 9, 122. 114 NUNN, J. F. Unpublished observations, quoted by Neematallah, F. A., Chapman, L. M. and Sykes, M. K. (1963). Possible sources of error in the determination of arterial carbon dioxide tension by an interpolation technique. Br. J. Anaesth., 35, 338. 115 GAMBINO, S. R. (1959). Comparisons of pH in human arterial, venous and capillary blood. Am J. clin. Path., 32, 298. 116 BROOKS, D. and WYNN, V. (1959). Use of venous blood for pH and carbon-dioxide studies especially in respiratory failure and during anaesthesia. Lancet, i, 227. 117 GANDY, G., GRANN, L., CUNNINGHAM, N., ADAMSONS, K. and JAMES, L. S. (1964). The validity of pH and Pco2 measurements in capillary samples in sick and healthy newborn infants. Pediatrics, Springfield, 34, 192. 118 Annotation (1965). Mercury embolism after blood-sampling. Lancet, ii, 1174. 119 DEVLIN, H. B. and SUDLOW, M. (1967). Peripheral mercury embolization occurring during arterial blood sampling. Br. med. J., i, 347. 120 LATHEM, W., LESSER, G. T., MESSINGER, W. J. and GALDSTON, M. (1954). Peripheral embolism by metallic mercury during arterial blood sampling. Archs intern. Med., 93, 550. 121 BUXTON, J. T., HEWITT, J. C, GADSDEN, R. H. and BRADHAM, G. B. (1965). Metallic mercury embolisation. J. Am. med. Ass., 193, 573. 122 FLENLEY, D. C, MILLAR, J. S. and REES, H. A. (1967). Accuracy of oxygen and carbon dioxide electrodes. Br. med. J., 2, 349. 123 CAMPBELL, E. J. M. (1960). Simplification of Haldane's apparatus for measuring CO2 concentration in respired gases in clinical practice. Br. med. J., 1, 457. 124 SIGGAARD-ANDERSEN, O. (1967). Therapeutic aspects of acid-base disorder. In Modern Trends in Anaesthesia, 3: Aspects of metabolism and pulmonary ventilation. Edited by F. T. Evans and T. C. Gray. London : Butterworths. 125 PRYS-ROBERTS, C, SMITH, W. D. A. and NUNN, J. F. (1967). Accidental severe hypercapnia during anaesthesia. Br. J. Anaesth. 39, 257. 126 GREENBAUM, R., NUNN, J. F., PRYS-ROBERTS, C. and KELMAN, G. R. (1967). Metabolic changes in whole human blood (in vitro) at 37°C. Resp. Physiol. 2, 274. 127 KELMAN, G. R. (1967). Correction factors to be applied to measured blood gas tensions and pH. Bio-med. Engng, 2, 362. 128 RAISON, J. C. A. (1965). Acid-base changes and tissue respiration in extracorporeal circulation. Ann. R. Coll. Surg., 37, 93. 129 Report of ad hoc committee on methodology of the New York Academy of Sciences Conference; Current concepts of acid-base measurement. (1966). Ann. N. Y. Acad. Sci., 133, 259. 130 ARMSTRONG, B. W., MOHLF, R. J. G., JUNG, R. C. and REMMERS, J. (1966). The in-vivo carbon dioxide titration curve. Estimation from measurements on a single sample of blood. Lancet, i, 759. 131 SEMPLE, S. J. G. (1967). Problems in measurement and interpretation of blood acid-base state. Bio-med. Engng, 2, 500. Citing Literature Volume23, Issue1March 1968Pages 47-64 ReferencesRelatedInformation
Referência(s)