Multipurpose assessment for the quantification of Vibrio spp. and total bacteria in fish and seawater using multiplex real‐time polymerase chain reaction
2014; Wiley; Volume: 94; Issue: 13 Linguagem: Inglês
10.1002/jsfa.6699
ISSN1097-0010
Autores Tópico(s)Identification and Quantification in Food
ResumoJournal of the Science of Food and AgricultureVolume 94, Issue 13 p. 2807-2817 Research ArticleOpen Access Multipurpose assessment for the quantification of Vibrio spp. and total bacteria in fish and seawater using multiplex real-time polymerase chain reaction Ji Yeun Kim, Ji Yeun Kim Department of Human Ecology, Food Science, College of Agriculture and Related Sciences, Delaware State University, Dover, DE 19901 USASearch for more papers by this authorJung-Lim Lee, Corresponding Author Jung-Lim Lee Department of Human Ecology, Food Science, College of Agriculture and Related Sciences, Delaware State University, Dover, DE 19901 USACorrespondence to: Jung-Lim Lee, Department of Human Ecology, Food Science, College of Agriculture and Related Sciences, Delaware State University, Dover, DE 19901, USA. E-mail: jlee@desu.eduSearch for more papers by this author Ji Yeun Kim, Ji Yeun Kim Department of Human Ecology, Food Science, College of Agriculture and Related Sciences, Delaware State University, Dover, DE 19901 USASearch for more papers by this authorJung-Lim Lee, Corresponding Author Jung-Lim Lee Department of Human Ecology, Food Science, College of Agriculture and Related Sciences, Delaware State University, Dover, DE 19901 USACorrespondence to: Jung-Lim Lee, Department of Human Ecology, Food Science, College of Agriculture and Related Sciences, Delaware State University, Dover, DE 19901, USA. E-mail: jlee@desu.eduSearch for more papers by this author First published: 21 April 2014 https://doi.org/10.1002/jsfa.6699Citations: 16AboutSectionsPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinkedInRedditWechat Abstract BACKGROUND This study describes the first multiplex real-time polymerase chain reaction assay developed, as a multipurpose assessment, for the simultaneous quantification of total bacteria and three Vibrio spp. (V. parahaemolyticus, V. vulnificus and V. anguillarum) in fish and seawater. The consumption of raw finfish as sushi or sashimi has been increasing the chance of Vibrio outbreaks in consumers. Freshness and quality of fishery products also depend on the total bacterial populations present. RESULTS The detection sensitivity of the specific targets for the multiplex assay was 1 CFU mL−1 in pure culture and seawater, and 10 CFU g−1 in fish. While total bacterial counts by the multiplex assay were similar to those obtained by cultural methods, the levels of Vibrio detected by the multiplex assay were generally higher than by cultural methods of the same populations. Among the natural samples without Vibrio spp. inoculation, eight out of 10 seawater and three out of 20 fish samples were determined to contain Vibrio spp. CONCLUSION Our data demonstrate that this multiplex assay could be useful for the rapid detection and quantification of Vibrio spp. and total bacteria as a multipurpose tool for surveillance of fish and water quality as well as diagnostic method. © 2014 The Authors. Journal of the Science of Food and Agriculture published by JohnWiley & Sons Ltd on behalf of Society of Chemical Industry. INTRODUCTION Vibrios are opportunistic human and fish pathogens present in marine and estuarine environments worldwide.1, 2 Vibrio infections are usually associated with the consumption of seafood or exposure of wounds to inhabited seawater.2 The incidence of Vibrio infections has increased by 43% between 2006 and 2012 in the US.3 While consumption of raw oysters has been a major cause of Vibrio infections in several countries, such as the US,4, 5 increasing the occasions of eating raw or undercooked finfish has also increased the possibility of Vibrio infection and, in some Asian countries, are considerably associated with consumption of finfish.6 In one case, fish-balls contaminated with Vibrio parahaemolyticus caused a food poisoning outbreak in Thailand.7 In Japan, sashimi and sushi, raw fish foods, were major causes of infection and occupied 26% and 23% of V. parahaemolyticus outbreaks in humans, respectively.8 In the US, the sushi industry has been growing by 1.6% annually through 2008–2013 and current numbers of sushi restaurants total 4135.9 At least 14 species of pathogenic Vibrio have been reported. Vibrio parahaemolyticus and V. vulnificus are the leading cause of illness due to seafood.2 According to the Centers for Disease Control and Prevention (CDC), 112 cases of V. parahaemolyticus and 25 cases of V. vulnificus infections occurred in 2012 and constituted 75% of all Vibrio spp. illnesses combined.3 Vibrio parahaemolyticus may cause acute gastroenteritis and septicemia; especially in people with liver or immune deficiencies.10 V. parahaemolyticus carries the thermolabile hemolysin (tlh) gene which has been used as a species-specific marker for V. parahaemolyticus.11, 12 Vibrio vulnificus is recognized as a highly invasive bacterium and leads to septicemia in immunocompromized individuals13, 14 as it has the highest mortality rate, greater than 50% for primary septicemia, and has led to approximately 40 deaths from seafood in the US annually.15 Some virulence genes of V. vulnificus, i.e. vvhA, vvpE, and rtxA1, have been reported but their mechanisms of action are not fully understood.13 Vibrio anguillarum causes vibriosis with lethal hemorrhagic septicemia in fish and shellfish that result in substantial economic losses in aquaculture farming worldwide16 as it has a homologue of V. cholerae EI Tor hemolysin17 and a virulence factor of V. cholerae and V. vulnificus such as vah1 and rtxA, respectively.18-20 A rapid method for the detection and quantification of vibrio pathogens is crucial in aquaculture for the detection of infected fish and to monitor seafood quality in marine environments. Although Vibrionaceae have generally been detected using selective medium, like thiosulfate citrate bile salts sucrose agar (TCBS),21-23 this method does not indicate the species of Vibrio. Conventional polymerase chain reaction (PCR) assays provide rapid, specific, and sensitive analysis of targeted vibrios, but cannot make quantitative measurements.24-26 In comparison to conventional PCR, a current real-time PCR method is quantitative, more rapid, and about 100 times more sensitive.27, 28 High bacterial populations in and on aquaculture products affect their quality, shelf-life,29 and suggests the possibility of increased numbers of potential human pathogens.30 The goal of the current study was to develop and evaluate a multiplex real-time PCR assay that would provide a rapid, sensitive, and quantitative method for the detection of V. anguillarum, V. parahaemolyticus, V. vulnificus, and total bacteria in fish fillets and seawater. While there exist methods to detect V. cholerae, V. parahaemolyticus, and V. vulnificus using multiplex real-time PCR,31, 32 there are no methods to detect V. anguillarum and the other Vibrio spp. at the same time. Moreover, this study is the first attempt at multiplex real-time PCR to detect and quantify Vibrio spp. and total bacteria simultaneously. We describe a four-target multiplex real-time PCR assay using the Taqman system. This assay includes novel primers and probes for species-specific target genes, namely, tlh for V. parahaemolyticus, toxR for V. anguillarum, vvhA for V. vulnificus, and detection of a universal target, 16S rDNA for total bacteria. MATERIALS AND METHODS Bacterial cultures and DNA template preparation For the optimization of multiplex real-time PCR and generation of standard curves, V. anguillarum HB155721 (Carolina Biological Supply Co., Burlington, NC, USA), V. parahaemolyticus O1:Kuk, and V. vulnificus MLT1009 (U.S. Department of Agriculture – Agricultural Research Service, Dover, DE; USDA-ARS) were used. Mixed bacteria from sea bass were used to generate a total bacterial sample, which was prepared by overnight culture at 29°C in tryptic soy broth (TSB; Carolina Biological Supply Co.) with shaking (130 rpm). A 1:50 dilution of V. anguillarum and a 1:100 dilution of V. vulnificus were maintained in TSB supplemented with additional 20 g L−1 NaCl (TSB+) and incubated for 4–5 h at 29°C with shaking (130 rpm) to achieve an early-exponential phase culture. A 1:100 dilution of V. parahaemolyticus overnight culture was incubated for 2–3 h under the same conditions as the other Vibrio species. A 1:100 dilution of total bacteria was cultured for 4–5 h at 29°C in TSB. Vibrio cultures in 8.5 g L−1 saline buffer were spread at ten-fold dilutions on tryptic soy agar supplemented with 20 g L−1 NaCl (TSA+) and incubated for 24 h at 29°C. Decimal diluted total bacterial culture was plated on TSA and cultured for 3 days at 29°C to determine the CFU mL−1 of each strain. Approximately 1 × 107 CFU mL−1 of diluted bacterial cultures (1 mL) were centrifuged for 5 min at 10 000 × g and the supernatant was discarded. The pellets were suspended in 400 μL of TZ buffer (20 g L−1 Triton X-100 and 2.5 mg mL−1 sodium azide in 0.1 mol L−1 Tris-HCl, pH 8.0) and boiled for 10 min.30, 33 Cell debris were discarded by centrifugation for 5 min at 10 000 × g and supernatants containing crude DNA extract were transferred to a fresh tube. Twenty microliters of Quick-Precip Plus Solution (EdgeBio, Gaithersburg, MD, USA) and 800 µL of absolute ethanol (Fisher Scientific, Fair Lawn, NJ, USA) were added to the supernatants to precipitate genomic DNA. After centrifugation (5 min, 13 000 × g), the pellets were washed with 700 mL L−1 ethanol and dried at room temperature. The pelleted DNA was dissolved in nuclease-free water. Design and evaluation of primers and probes for multiplex real-time PCR At least six ORF sequences of each species-specific target gene, tlh, toxR and vvhA, were obtained from GenBank and aligned using the Clustal W program. To detect total bacteria, universal primers and a probe were designed using the conserved regions of 16S rDNA following the alignment of 32 sequences from a host of bacteria based on Bergey's Manual of Determinative Bacteriology.34 The 16S rDNA sequences (GenBank accession numbers in parentheses) were aligned using Clustal W for the following strains arranged by differentiation via Gram stains and cell morphology: Gram-positive cocci: Staphylococcus (GQ911564.1), Micrococcus (JQ726627.1), Peptococcus (AB644260.1), Streptococcus (EU156766.1), Peptostreptococcus (AY359243.2), Enterococcus (AB681177.1) Gram-positive bacilli: Listeria (JF967624.1), Erysipelothrix (AB685261.1), Bacillus (JQ905096.1), Clostridium (GQ911558.1), Streptomyces (AB184358.1), Lactobacillus (AB680529.1), Eggerthella (HQ455039.1) Gram-negative cocci: Veillonella (HM007566.1) Gram-negative bacilli: Acinetobacter (EF672504.1), Brucella (JN571438.1), Bordetella (AB682670.1), Bacteroides (HE608159.1), Haemophilus (EU909679.1), Pasteurella (HE800437.1), Francisella (JQ277265.1), Eikenella (JN713283.1), Cardiobacterium (M35014.1), Streptobacillus (JQ087393.1), Vibrio (AY292952.1), Campylobacter (GQ167677.1), Aeromonas (JQ781582.1), Alcaligenes (FJ151629.1), Chromobacterium (FJ753567.1), Escherichia coli (JQ904752.1), and Salmonella (JQ074173.1). The Primer3 program (http://biotools.umassmed.edu/bioapps/primer3_www.cgi) was used to design oligonucleotide primers and TaqMan probes targeting highly conserved regions of each genes. The PriDimerChecking program was used to check dimerization among primers and probe and the species-specific primers and probes were validated for high specificity by Blast analysis (NCBI). The primer and probe sequences are listed in Table 1. Table 1. Primer and probe sequences used in this study Name (accession #) Start Sequence Modification 16S-F (JQ904752.1)a 226 5′-cccagatgggattagcttgt-3′ — 16S-R 331 5′-tctggaccgtgtctcagttc-3′ — 16S-P 270 5′-cgacgatccctagctggtctgaga-3′ 5′ ROX to 3′ BHQ2 tlh-F (GU971655.1) 237 5′-ctactggtggagctccgttt-3′ — tlh-R 354 5′-cgtaatgtctgcgttctcgt-3′ — tlh-P 277 5′-accaacacgtcgccaaacgttatc-3′ 5′ JOE to 3′ BHQ1 toxR-F (AJ299739.1) 162 5′-acactgcaaagcaaattgatg-3′ — toxR-R 295 5′-tgatgggcgtattcacaact-3′ — toxR-P 212 5′-tggctcttctattgactagccctgca-3′ 5′ TAMRA to 3′ BHQ2 vvhA-F (JF718659.1) 273 5′-ccaagtttggggcctagata-3′ — vvhA-R 365 5′-actgtgagcgttttgtctgc-3′ — vvhA-P 315 5′-agtggcatccgatcgttgtttgac-3′ 5′ FAM to 3′ BHQ1 a This accession number represents 32 alignment species to design 16S rDNA primers. Optimization of multiplex real-time PCR Primers, probe concentrations, and the real-time PCR protocol including annealing temperatures, reaction times, and cycling numbers were optimized for the multiplex detection and quantification of the 16S rDNA, tlh, toxR, and vvhA genes using the StepOnePlus real-time PCR platform (Applied Biosystems, Foster City, CA, USA). For comparison of PCR performance, the real-time PCR was conducted using three types of commercial real-time PCR master mixes. Those were IQ Multiplex Powermix (Bio-Rad Laboratories, Inc., Hercules, CA, USA), Express qPCR Supermix Universal (Invitrogen, Carlsbad, CA, USA), and Premix Ex Taq (TaKaRa Bio Inc., Shiga, Japan) and they were randomly represented as master mix A, B and C, respectively. The optimal reaction mixture components for a 25 µL volume were 12.5 µL of 2X master mix, 800 nmol L−1 each of the toxR forward and reverse primers and probe; 200 nmol L−1 each of the 16S rDNA forward and reverse primers and probe; and 50 nmol L−1 each of the tlh and vvhA forward and reverse primers and probe. The remainder of the reaction volume consisted of DNA template and nuclease-free water. The optimal cycling parameters consisted of a 95°C initial denaturation hold for 2 min followed by 35 cycles of amplification, with each cycle consisting of denaturation at 95°C for 15 s and a combined annealing/extension step at 60°C for 50 s. For negative control, nuclease-free water was added to the reaction mixture as a template for every real-time PCR assay and fluorescence was read at the end of each amplification cycle. Generation of standard curves For the determination of detection and quantitative capabilities from fish and seawater samples, standard curves of the four target genes (16S, tlh, toxR, and vvhA) were generated during multiplex real-time PCR amplification. DNA templates of each strain were prepared from a ten-fold dilution series of three Vibrio spp. and total bacteria in 8.5 g L−1 saline buffer. The dilution series for the PCR assay were run in triplicate for three independent experiments. The standard curves were determined by plotting the Ct values against the log CFU reaction−1 and the slope was generated by linear regression of plotted points. Specificity and sensitivity test The multiplex real-time PCR assay was tested for specificity against a panel of 37 bacterial strains including 11 Vibrio spp., three Bacillus spp., two E. coli strains, three Pseudomonas spp., and 18 other strains (Table 2). These strains were obtained from the American Type Culture Collection (ATCC, Manassas, VA, USA), Carolina Biological Supply Co., the USDA-ARS, and the previous study.35 The sensitivity of the multiplex assay from artificially inoculated seawater and fish samples was tested from log 5 to log 0 CFU mL−1 as well as from log 3 to log 0 CFU g−1, respectively. Table 2. Bacterial strains used to test the specificity of multiplex real-time polymerase chain reaction (PCR) Species Strain Source Real-time PCR results (+/−) 16S tlh toxR vvhA Vibrio anguillarum HB155721 Carolina + − + − Vibrio anguillarum — USDA-ARS + − + − Vibrio cholerae 01 — USDA-ARS + − − − Vibrio fischeri — USDA-ARS + − − − Vibrio harveyi — USDA-ARS + − − − Vibrio mimicus ATCC 33654 ATCC + − − − Vibrio parahaemolyticus O1:Kuk — USDA-ARS + + − − Vibrio parahaemolyticus O3:K6 — USDA-ARS + + − − Vibrio vulnificus 15 USDA-ARS + − − + Vibrio vulnificus MLT 367 USDA-ARS + − − + Vibrio vulnificus MLT1009 USDA-ARS + − − + Aeromonas sobria D36 Hickey et al.35 + − − − Bacillus cereus # 5056 USDA-ARS + − − − Bacillus cereus HB154870 Carolina + − − − Bacillus subtilis HB154921 Carolina + − − − Clostridium butyricum HB154965 Carolina + − − − Enterococcus faecalis HB155600 Carolina + − − − Escherichia coli DH5a ATCC67876 ATCC + − − − Escherichia coli O157:H7 — USDA-ARS + − − − Lactococcus lactis HB155610 Carolina + − − − Photobacterium kishitanni — USDA-ARS + − − − Pseudomonas aeruginosa ATCC 10145 ATCC + − − − Pseudomonas fluorescens ATCC 13525 ATCC + − − − Pseudomonas putida 155265 Carolina + − − − Salmonella enteritidis HB155350A Carolina + − − − Salmonella enteritidis SA 36 USDA-ARS + − − − Salmonella heidelberg SA 42 USDA-ARS + − − − Salmonella montevideo SA 40 USDA-ARS + − − − Salmonella newport SA 41 USDA-ARS + − − − Salmonella typhimurium HB155351A Carolina + − − − Salmonella typhimurium SA 34 USDA-ARS + − − − Serratia marcascens SM51 USDA-ARS + − − − Shewanella algae ATCC 51192 ATCC + − − − Shewanella baltica NCTC 10735 USDA-ARS + − − − Shewanella baltica D10 Hickey et al.35 + − − − Staphylococcus aureus ATCC 12598 ATCC + − − − Staphylococcus aureus HB155554A Carolina + − − − ATCC, American Type Culture Collection; USDA-ARS, US Department of Agriculture – Agricultural Research Service. Fish sample collection and processing In total, 30 fish were used for this study. Ten fish fillet samples were purchased from local retail or fresh fish markets in Dover, Delaware, USA. Samples consisted of sea bass (Centropristis striata), cod fish (Gadus morhua), flounder (Paralichthys), and haddock (Melanogrammus aeglefinus). The fish fillets were cut into small pieces and 25 g were put into stomacher bags (Interscience, St. Nom, France). A low level (Log 2 CFU g−1) of each Vibrio culture in PBS was added to fish samples and were maintained for 1 h in the refrigerator (4°C). In the stomacher bags, 75 mL of PBS was added and the fish samples were homogenized using a Bag Mixer (Interscience) for 10 min. Ten milliliters of each homogenized fish fillet were centrifuged at 150 × g for 5 min to remove larger pieces. Each supernatant was re-centrifuged at 5000 × g for 10 min and the supernatants were discarded. The pellets were resuspended in 1 mL of PBS and used for quantitative detection of Vibrio spp. and total bacteria by the plate count method and by multiplex real-time PCR. In addition, 20 fish fillets were obtained from aquaculture facility at Delaware State University (DSU) and local retail sources in Dover, Delaware, USA. The fillets used in this study were: sea bass (Centropristis striata), cod fish (Gadus morhua), flounder (Paralichthys), haddock (Melanogrammus aeglefinus), hybrid striped bass (Morone Chrysops × Morone saxatilis), mummichog (Fundulus heteroclitus), and tilapia (Oreochromis mossambicus). The processing was the same as above excluding the inoculation of Vibrio spp. Seawater collection and processing A total of 15 different seawater samples were collected from February to November of 2013. Artificial seawater was made according to instructions of the manufacturer (Instant Ocean sea salt; Aquarium System Inc., Blacksburg, VA, USA) and autoclaved at 121°C for 17 min. Fourteen seawater samples were collected at different locations and on different days. Four Atlantic Ocean water samples were collected from the Indian River inlet, Delaware. Four Delaware Bay seawater samples were collected from Bowers beach, Delaware. Six aquaculture seawater samples were collected from the aquaculture facility at DSU. Within 24 h of collection, water samples were vacuum filtered through Whatman #40 filter paper (Whatman, Buckinghamshire, UK) to remove algae, debris, and grit. One artificial seawater and 4 natural seawater filtrates were artificially inoculated with low levels (Log 2 CFU mL−1) of Vibrio cultures (V. anguillarum, V. parahaemolyticus, and V. vulnificus in phosphate-buffered saline; PBS) and maintained for 1 h at room temperature. Both of the five Vibrio-inoculated and 10 non-inoculated seawater were used for quantitative detection of Vibrio spp. and total bacteria by the plate count method and multiplex real-time PCR. Quantification of Vibrio spp. and total bacteria from the samples by culture-dependent bacterial enumeration The processed seawater and fish samples were serially diluted ten-fold in PBS and spread on TCBS (Difco, Sparks, MD, USA) and TSA plates. The TCBS plates were incubated for 24 h at 29°C and the TSA plates were cultured for 3 days at 29°C. The colonies on the TCBS plates were enumerated to quantify Vibrio spp. and those on the TSA were counted to quantify total bacteria. Quantification of Vibrio spp. and total bacteria using multiplex real-time PCR The processed water samples were vacuum filtered through polyethersulfone membrane filters (0.22 µm pore size, 25 mm diameter; Whatman) and the filters were put into microcentrifuge tubes to extract bacterial DNA. Fish samples described above were centrifuged at 13 000 × g for 5 min and the pellets were used for template DNA preparation. Two hundred microliters of 2 × TZ buffer was added to microcentrifuge tubes containing a filter from the water samples or resuspended pellets from the fish samples. Six percent Chelex solution (Bio-Rad) was added and the microcentrifuge tubes were vortexed for 2 min. The tubes were boiled for 10 min, centrifuged at 10 000 × g for 5 min, and the supernatants were retained. The following precipitation processes of genomic DNA were the same as the DNA template preparation from the pure culture and the multiplex real-time PCR assay were decribed above. Quantification of Vibrio spp. and total bacteria were evaluated using the strandard curves as previously described. Statistical analysis The T-test was used to determine statistically significant differences between the Ct values resulted from multiplex real-time PCR assays for PCR optimization. The SPSS 12.0K for windows software (SPSS Inc., Chicago, IL, USA) was used to explore the statistical significance of results obtained. A confidence interval at the 95% level (P < 0.05) was considered in all cases. RESULTS Optimization of the PCR assay Blast analyses showed that the three specific TaqMan probes and pairs of primers designed in this study were highly specific for detection and quantification of Vibrio spp. This study assessed three different manufacturers' PCR master mixes for optimization of multiplex real-time PCR. Among them, 16S target (ROX dye) was not consistently detected in the PCR mixture using master mix C, whereas, master mix B showed lower Ct values compared with master mix A (Table 3). Therefore, master mix B was chosen for this multiplex assay. Table 3. Ct values of four gene targets (16S, tlh, toxR and vvhA) obtained from different primers and probe concentrations by multiplex real-time polymerase chain reaction (PCR) Primer and probe conc. (nmol L−1) Ratio, tlh/toxR 16S tlh toxR vvhA 16S tlh toxR vvhA MM-A MM-B MM-C MM-A MM-B MM-C MM-A MM-B MM-C MM-A MM-B MM-C 200 200 200 200 1/1 22.09 ± 0.21a 20.06 ± 0.08 NDb 17.18 ± 0.23 19.00 ± 0.06 18.45 ± 0.18 ND ND ND 16.99 ± 0.62 18.68 ± 0.10 19.52 ± 0.08 200 200 200 100 1/1 22.19 ± 0.48 20.13 ± 0.32 ND 17.48 ± 0.28 18.90 ± 0.24 18.60 ± 0.40 ND ND ND 17.87 ± 0.25 18.48 ± 0.20 19.48 ± 0.08 200 200 200 50 1/1 22.54 ± 0.50 19.63 ± 0.15 ND 17.25 ± 0.02 19.01 ± 0.01 18.73 ± 0.21 ND ND ND 19.62 ± 0.36 19.10 ± 0.65 19.42 ± 0.03 200 100 200 50 1/2 22.34 ± 0.13 19.83 ± 0.42 ND 17.77 ± 0.13 18.81 ± 0.24 19.17 ± 0.04 ND ND ND 19.67 ± 0.04 18.51 ± 0.23 19.59 ± 0.19 200 50 200 50 1/4 22.50 ± 0.05 19.53 ± 0.4 ND 21.10 ± 0.21 18.87 ± 0.11 19.40 ± 0.28 34.97 ± 0.4 16.24 ± 0.08 18.88 ± 0.38 19.24 ± 0.2 18.45 ± 0.03 19.29 ± 0.34 200 50 400 50 1/8 22.63 ± 0.09 19.66 ± 0.11 ND 20.45 ± 0.34 18.99 ± 0.18 19.46 ± 0.43 16.85 ± 0.03 16.09 ± 0.16 18.58 ± 0.09 20.19 ± 0.03 18.53 ± 0.05 19.31 ± 0.20 200 50 800 50 1/16 22.57 ± 0.35 19.59 ± 0.21 ND 20.24 ± 0.36 19.07 ± 0.10 19.47 ± 0.25 16.42 ± 0.34 15.86 ± 0.13 18.52 ± 0.28 20.20 ± 0.27 18.64 ± 0.11 19.40 ± 0.04 a Mean ± standard deviation. b No amplicon detected. MM, Master mix. Primer and probe concentrations were optimized for the detection of low numbers of bacteria as well as maximization of primer and probe efficiencies. While the Ct value of the 16S rDNA gene was higher with reduced primer and probe concentrations, the Ct values of tlh and vvhA were not significantly different even with lower concentrations of primer and probe in the multiplex assay (Table 3). Therefore, the concentration of 16S primers and probe was fixed at 200 nM and primer and probe concentrations of tlh and vvhA were reduced to 50 nM (Table 3). ToxR was best detected with primers and probe at 800 nM (Table 3). The relative fluorescence curve of toxR was retarded at primer and probe concentrations up to 400 nM (Fig. 1A). As shown in Table 3, toxR amplification signal was influenced by the ratio of final concentration of tlh and toxR primers and probes. When the molar ratios of tlh and toxR were higher than 1:4 (tlh:toxR), toxR was not detected. In addition, the lower ratio of tlh/toxR (1:16) gave the lowest Ct value for toxR targets (Table 3). Figure 1Open in figure viewerPowerPoint Multiplex real-time PCR amplification curves of a toxR target obtained from (A) different primers and probe concentration, (curve a) 800 nM, (curve b) 400 nM, and (curve c) 200 nM of toxR primers and probe; and (B) different annealing and extension temperature.; annealing and extension temperatures at (curve a) 60°C, (curve b) 62°C, (curve c) 58°C, and (curves d and e) 56 and 64°C. To optimize the annealing/extension temperature, we performed temperature gradient assays from 56 to 64°C. The lowest temperature used for 16S, tlh and vvhA targets (56°C) produced the lowest Ct values (Table 4). On the other hand, toxR targets were lowest at 60°C in the PCR mixture using master mix B. Additionally, the amplification curves of toxR were not suppressed at 60 and 62°C when master mix B was used (Fig. 1B). Table 4. Ct values of four gene targets (16S, tlh, toxR and vvhA) obtained from different annealing/extension temperature by multiplex real-time polymerase chain reaction (PCR) Annealing temp (°C) 16S tlh toxR vvhA MM-A MM-B MM-C MM-A MM-B MM-C MM-A MM-B MM-C MM-A MM-B MM-C 56 21.01 ± 0.32a 18.49 ± 0.35 NDb 19.33 ± 0.21 18.52 ± 0.52 17.99 ± 0.43 ND 16.64 ± 0.03 18.34 ± 0.18 20.31 ± 0.19 18.16 ± 0.06 18.70 ± 0.07 58 21.24 ± 0.11 19.50 ± 0.17 ND 19.82 ± 0.04 19.07 ± 0.04 17.68 ± 0.11 ND 16.96 ± 0.33 19.29 ± 0.21 20.63 ± 0.28 18.45 ± 0.08 18.59 ± 0.03 60 21.33 ± 0.39 20.51 ± 0.22 ND 20.43 ± 0.02 18.90 ± 0.24 18.32 ± 0.51 16.67 ± 0.19 15.85 ± 0.12 17.98 ± 0.01 20.82 ± 0.01 18.94 ± 0.21 18.85 ± 0.2 62 23.16 ± 0.10 22.14 ± 0.06 ND 20.66 ± 0.11 20.24 ± 0.14 19.63 ± 0.69 18.28 ± 0.32 16.75 ± 0.07 19.59 ± 0.47 21.09 ± 0.00 19.06 ± 0.04 19.34 ± 0.14 64 23.38 ± 0.03 23.09 ± 1.01 ND 20.97 ± 0.08 21.96 ± 0.25 23.46 ± 0.47 18.53 ± 0.17 17.47 ± 0.25 19.74 ± 0.06 21.07 ± 0.05 19.15 ± 0.10 22.36 ± 0.16 a Mean ± standard deviation. b No amplicon detected. MM, Master mix. The real-time PCR reaction time was optimized for rapid detection. The Ct values of all four targets showed no significant differences (P > 0.05) with denaturation for 15–20 s and annealing/extension for 50 s to 1 min. Ct values with combined annealing/extension for 40 s were the least desirable with the highest Ct values detected (16S, 24.94 ± 0.33; tlh, 19.66 ± 0.37; toxR, not detected; vvhA, 24.80 ± 0.18, used master mix B). The optimal conditions for the multiplex real-time PCR in a 25 µL reaction volume requires the following: 800 nmol L−1 of each primer and probe for toxR, 200 nmol L−1 of each of primer and probe for the 16S rDNA, and 50 nmol−1 of each primers and probe for tlh and vvhA forward. The optimal cycling parameters consisted of a 95°C hold for 2 min for the initial denaturation followed by 40 cycles of DNA amplification, for each cycle followed by denaturation at 95°C for 15 s and a combined annealing/extension step at 60°C for 50 s. Standard curve In order to verify the sensitivity of the method and the consistency of quantitative measurement, DNA was prepared from a 10-fold diluted pure cultures of Vibrio spp. and in total bacteria to be analyzed using the multiplex real-time PCR. The three standard curves of specific targets obtained from each Vibrio strain in the range of log 0 to log 5 CFU per PCR assay and the standard curve of 16S was generated in the range of log 0.6 to log 5.6 CFU per reaction (Fig. 2). The standard curves of specific targets showed excellent correlations of linear regression with r2 coefficients: tlh, toxR, and vvhA were 0.990, 0.997, and 0.993, respectively, from three independently performed experiments and the coefficient for the 16S standard curve was 0.978. Figure 2Open in figure viewerPowerPoint Standard curves of four targets: (A) 16S, (B) tlh, (C) toxR, and (D) vvhA for quantification, plotting Ct values and Log CFU. Pure cultured Vibrio anguillarum, V. parahaemolyticus, and V. vulnificus were used ranges from Log 0 CFU to Log 5 CFU and total bacteria was used ranged from Log 0.6 CFU to Log 5.6 CFU. Specificity and sensitivity of PCR The multiplex real-time PCR assay was tested for specificity against 37 bacteria (Table 2). Vibrio anguillarum was positive for toxR
Referência(s)