Análisis de la eficacia de agentes químicos de desinfección en materiales elastoméricos

2007; Volume: 45; Issue: 1 Linguagem: Espanhol

ISSN

0001-6365

Autores

Rogéli Tibúrcio Ribeiro da Cunha Peixoto, Herbert Haueisen Sander, Paulo Henrique Amêndola Couto, Leandro M. Diniz, Patrícia Valente Araújo, Vagner Rodrigues Santos, Luiz Thadeu de Abreu Poletto,

Tópico(s)

Dental materials and restorations

Resumo

El objetivo de este estudio fue evaluar la eficacia de agentes de desinfeccion indicados para polisulfuros (mercaptanos), polieteres y siliconas por condensacion y por adicion. Fueron confeccionadas noventa muestras de cada material, siendo treinta de ellas contaminadas con Streptococcus mutans o Staphylococcus aureus o Candida albicans. De cada solucion microbiana fueron retiradas diez muestras del polisulfeto y de ambas las siliconas, que fueron inmersas por diez minutos en glutaraldehido al 2% y otras diez inmersas en agua destilada esteril (controle negativo). Despues de un nuevo lavado en agua destilada, las muestras fueron transferidas a medios de cultivo esteriles. Las diez muestras restantes no fueron sometidas al agente de desinfeccion y fueron transferidas a medios asociados a agentes antimicrobianos especificos (control positivo). La turbidez de los medios de cultivo fue evaluada como indicativo del crecimiento microbiano siguiendose a la incubacion por 24 h a 37O C y se realizo la dilucion y sembrado en placas de Petri para contar las colonias. Para el polieter fue ejecutado el mismo procedimiento, pero el agente de desinfeccion usado fue el hipoclorito de sodio a 1. No hubo turbidez comprobatoria del crecimiento microbiano en ninguno de los medios de cultivo que contenian los especimenes sometidos a los agentes de desinfeccion. Se concluyo que el glutaraldehido al 2% es un agente de desinfeccion eficaz para el polisulfuro y para las siliconas por adicion y por condensacion, asi como el hipoclorito a 1% es eficaz para el polieter, para los microorganismos evaluados. SUMMARY The aim of this in vitro study was to evaluate the disinfection efficacy of elastomeric impression materials such as polysulfides, polyethers, condensation and addition silicones. Ninety samples of each material were made and every thirty samples contaminated with Streptococcus mutans or Staphylococcus aureus or Candida albicans. From each microbial solution there were taken ten samples of polysulfide and of both silicones which were immersed for ten minutes in a 2% glutaraldehyde solution and other ten immersed in sterile distilled water (negative control). After being washed again in distilled water, the samples were transferred to sterile culture medium. The last ten samples were not submitted to any disinfection agent and were transferred to mediums associated with specific anti-microbial agents (positive control). The turbidity of the culture mediums was evaluated as an indication of the microbial growth after a period of 24-hour incubation at 37oC and the dilution and seeding in Petri dishes were done to count the colonies. The same procedure was done for the polyether, but the disinfection agent used was 1% sodium hypoclorite. There was no proved turbidity of the microbial growth in any of the culture mediums which had samples submitted to the disinfection agents tested. It was concluded that the 2% glutaraldehyde is an effective disinfection agent to polysulfides and to both condensation and addition silicones, as well as 1% sodium hypoclorite is effective to polyether, for the tested microorganisms. RESUMO O objetivo deste estudo in vitro foi avaliar a eficacia de agentes de desinfeccao indicados para polissulfetos, polieteres e siliconas de condensacao e adicao. Foram confeccionadas noventa amostras de cada material, sendo cada trinta contaminadas com Streptococcus mutans, Staphylococcus aureus ou Candida albicans. De cada solucao microbiana foram retiradas dez amostras do polissulfeto e de ambas as siliconas, que foram imersas por dez minutos no glutaraldeido a 2% e outras dez imersas em agua destilada esteril (controle negativo). Apos nova lavagem em agua destilada, as amostras foram transferidas para meios de cultura estereis. As dez amostras restantes nao foram submetidas ao agente de desinfeccao e foram transferidas para meios associados a agentes antimicrobianos especificos (controle positivo). A turbidez dos meios de cultura foi avaliada como indicativo de crescimento microbiano apos incubacao por 24 h a 37O C e realizou-se a diluicao e semeadura nas placas de Petri para contagem de colonias. Para o polieter foi executado o mesmo procedimento, porem o agente de desinfeccao empregado foi o hipoclorito de sodio a 1%. Nao houve turvacao comprobatoria de crescimento bacteriano em nenhum dos meios da cultura que continham corpos de prova submetidos aos agentes de desinfeccao. Concluiu-se que o glutaraldeido a 2% e um agente de desinfeccao eficaz para o polissulfeto e para as siliconas por adicao e por condensacao, assim como o hipoclorito a 1% e eficaz para o polieter, para os microorganismos testados.

Referência(s)