Quantification of EEG reactivity in comatose patients
2015; Elsevier BV; Volume: 127; Issue: 1 Linguagem: Inglês
10.1016/j.clinph.2015.06.024
ISSN1872-8952
AutoresM.C. Hermans, M. Brandon Westover, Michel J. A. M. van Putten, Lawrence J. Hirsch, Nicolas Gaspard,
Tópico(s)Traumatic Brain Injury Research
ResumoEEG reactivity is an important predictor of outcome in comatose patients. However, visual analysis of reactivity is prone to subjectivity and may benefit from quantitative approaches.In EEG segments recorded during reactivity testing in 59 comatose patients, 13 quantitative EEG parameters were used to compare the spectral characteristics of 1-minute segments before and after the onset of stimulation (spectral temporal symmetry). Reactivity was quantified with probability values estimated using combinations of these parameters. The accuracy of probability values as a reactivity classifier was evaluated against the consensus assessment of three expert clinical electroencephalographers using visual analysis.The binary classifier assessing spectral temporal symmetry in four frequency bands (delta, theta, alpha and beta) showed best accuracy (Median AUC: 0.95) and was accompanied by substantial agreement with the individual opinion of experts (Gwet's AC1: 65-70%), at least as good as inter-expert agreement (AC1: 55%). Probability values also reflected the degree of reactivity, as measured by the inter-experts' agreement regarding reactivity for each individual case.Automated quantitative EEG approaches based on probabilistic description of spectral temporal symmetry reliably quantify EEG reactivity.Quantitative EEG may be useful for evaluating reactivity in comatose patients, offering increased objectivity.
Referência(s)