Artigo Revisado por pares

Comparison of gradient-recalled-echo and T2-weighted spin-echo pulse sequences in intramedullary spinal lesions.

1989; American Society of Neuroradiology; Volume: 10; Issue: 4 Linguagem: Inglês

ISSN

1936-959X

Autores

B Katz, R M Quencer, R. Scott Hinks,

Tópico(s)

Advanced Neuroimaging Techniques and Applications

Resumo

Nineteen consecutive patients with spinal intramedullary lesions were studied on a 1.5-T system to compare the quality of T2-weighted spin-echo and gradient-recalled-echo (GRE) pulse sequences. Direct comparisons were made in the sagittal and/or axial planes. Twenty-four studies were performed in the 19 patients. The gradient echoes were usually performed at 300/14 (TR/TE) with a flip angle of 10 degrees. Although no significant diagnostic differences were noted in the sagittal plane, there was a distinct anatomic advantage for GRE imaging over spin-echo imaging in the axial plane. This is believed to be the result of CSF time-of-flight effects in the slice-select direction, which are not compensated for by flow-compensating gradients on the spin-echo images, but which are insignificant in the GRE sequence used in this study. Pathology was seen equally well or better on GRE in 79% (19/24) of the sequences. In the other five cases, the spin-echo image showed a brighter intramedullary signal than that seen on GRE, although GRE showed the lesion in all cases. Our results indicate that properly optimized GRE imaging on a high-field-strength system can replace spin-echo imaging in the spine when intramedullary disease is suspected and that the benefits of GRE are most striking in the axial plane.

Referência(s)