Some aspects of the measurement of 32P Cerenkov radiation in water by a liquid scintillation spectrometer
1971; Pergamon Press; Volume: 22; Issue: 8 Linguagem: Inglês
10.1016/0020-708x(71)90166-9
ISSN1878-1284
AutoresLeonard I. Wiebe, A.A. Noujaim, C. Ediss,
Tópico(s)Radiation Detection and Scintillator Technologies
ResumoThe shift of the pulse height spectrum and the relative counting efficiency of 32P Cerenkov radiation in water were examined using a liquid scintillation spectrometer. This shift was related to the spectrophotometric absorbancy of samples containing various dyes. The isotope channels ratio method of producing a counting efficiency correction curve was found to be effective for coloured samples. It was observed that although the addition of some chemicals to the sample caused little change in the counting efficiency, a suspending agent (Cabo-sil∗®) produced a counting efficiency and spectral shift different from those obtained for the samples containing dyes. The absolute counting efficiency for 32P in water was found to be 30·5 per cent. On examina le déplacement du spectre de hauteurs de pulsations et l'efficacité rélative de comptage du rayonnement Cerenkov du 32P dans l'eau, employant un spectromètre à scintillation liquide. Ce déplacement eut un rapport avec l'absorbance spectrophotométrique des échantillons qui contenaient de différentes teintures. On trouva que la méthode du rapport des canaux d'isotopes pour produire une courbe de correction pour l'efficacité de comptage servait pour les échantillons colorés. On observa que, quoique l'addition de certains produits chimiques rendît peu de changement de l'efficacité de comptage, un agent suspenseur (Cab-o-sil∗®) rendit une efficacité et un déplacement spectral différents à ceux rendus par les échantillons qui contenaient des teintures. On trouva que l'efficacité absolue de comptage pour le 32P dans l'eau était 30,5 pour cent. Пpи пoмoщи жидкocтнoгo cцинтилляциoннo гo cпeктpoмeтpa иccлeдoвaлиcь cдвиг aмплитyд0нoгo cпeктpa импyльcoв и oтнocитeлвнycy;й cчeтный кoэффициeнт излyчeния 32P чepeнкoвa в вoдe. Этoт cдвиг был cвяaн co cпeктpoфoтoмeтpичecкoй cпocoбнocтью oбpaзцoв, coдepжaшич paзлчныe кpacяшиe вeшecтвa. Meтoд cooтнoшeний изoтoпныч кaнaлoв для пoлyчeния кpивoй К.П.Д. пoдc7chcy;eтa oкaзaлcя эффeктивным для цвeтныч oбpaзцoв. Зaмeчeнo, чтo чoтя пpибaвлeниe нeккoтopыч чимикaлий к oбpaзцy и вызывaeт нeбoльшoe измeнeиe К.П.Д. cчeтa, нo тopмoзяший aгeнт (Cab-o-sil)† вызывaл К.П.Д. cчeтa и cдвиг cпeктpa oтличныe oт пoлyчaeмыч пpи oбpaзцaч, coдepжaшич кpacитeли. Aбcoлютный К.П.Д. для 32P в вoдe oкaзaлcя 30,5%. Die Verschiebung des Impulshöhenspektrums und die relative Zählungsausbeute der 32P-Cerenkov-Strahlung in Wasser wurden unter Verwendung eines Flüssigkeits-Szintillations-Spektrometer geprüft. Diese Verschiebung stand in Beziehung zu der spektrophotometrischen Absorptionsfähigkeit von Proben mit einem Gehalt an verschiedenen Farbstoffen. Man fand, dass das Isotopenkanalverhältnis-Verfahren sich für die Herstellung einer Kurve zur Korrektur der Zählungsausbeute für farbige Proben gut eignet. Es wurde beobachtet, dass, obwohl der Zusatz einiger Chemikalien zur Probe wenig an der Zählungsausbeute änderte, ein Suspensionsmittel (Gab-o-sil) (eingetragenes Warenzeichen der Cabot Corporation) eine Zählungsausbeute und Spektralverschiebung hervorbrachte, die sich von denen für Proben mit einem Farbstoffgehalt unterschieden. Die absolute Zählungsausbeute für 32P in Wasser wurde zu 30,5% gefunden.
Referência(s)