Artigo Acesso aberto Revisado por pares

Ballistocardiography

1953; Lippincott Williams & Wilkins; Volume: 7; Issue: 2 Linguagem: Inglês

10.1161/01.cir.7.2.268

ISSN

1524-4539

Autores

Richard Gubner, Manuel Rodstein, Harry E. Ungerleider,

Tópico(s)

Phonocardiography and Auscultation Techniques

Resumo

HomeCirculationVol. 7, No. 2Ballistocardiography Free AccessResearch ArticlePDF/EPUBAboutView PDFSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessResearch ArticlePDF/EPUBBallistocardiography An Appraisal of Technic, Physiologic Principles, and Clinical Value RICHARD S. GUBNER, MANUEL RODSTEIN and HARRY E. UNGERLEIDER RICHARD S. GUBNERRICHARD S. GUBNER From the Medical Research Department, Equitable Life Assurance Society of the U.S., 393 Seventh Avenue, New York, N. Y. , MANUEL RODSTEINMANUEL RODSTEIN From the Medical Research Department, Equitable Life Assurance Society of the U.S., 393 Seventh Avenue, New York, N. Y. and HARRY E. UNGERLEIDERHARRY E. UNGERLEIDER From the Medical Research Department, Equitable Life Assurance Society of the U.S., 393 Seventh Avenue, New York, N. Y. Originally published1 Feb 1953https://doi.org/10.1161/01.CIR.7.2.268Circulation. 1953;7:268–286 Previous Back to top Next FiguresReferencesRelatedDetailsCited By Liu Y, Lyu Y, He Z, Yang Y, Li J, Pang Z, Zhong Q, Liu X, Zhang H and Sun L (2022) ResNet-BiLSTM: A Multiscale Deep Learning Model for Heartbeat Detection Using Ballistocardiogram Signals, Journal of Healthcare Engineering, 10.1155/2022/6388445, 2022, (1-11), Online publication date: 27-Jan-2022. Salman H, Al‐Ruweidi M, Ouakad H and Yalcin H (2022) Minimally Invasive and Non‐Invasive Sensor Technologies for Predicting Heart Failure Predicting Heart Failure, 10.1002/9781119813040.ch5, (109-138), Online publication date: 22-Apr-2022. Yang C, Ku G, Lee J and Kim K (2021) Improving the Accuracy of Biosignal Analysis Using BCG by Applying a Signal-to-Noise Ratio and Similarity-Based Channel Selection Algorithm, Journal of Electrical Engineering & Technology, 10.1007/s42835-020-00601-8, 16:2, (1043-1050), Online publication date: 1-Mar-2021. Sadek I and Abdulrazak B (2021) A comparison of three heart rate detection algorithms over ballistocardiogram signals, Biomedical Signal Processing and Control, 10.1016/j.bspc.2021.103017, 70, (103017), Online publication date: 1-Sep-2021. Yao Y, Ghasemi Z, Shandhi M, Ashouri H, Xu L, Mukkamala R, Inan O and Hahn J Mitigation of Instrument-Dependent Variability in Ballistocardiogram Morphology: Case Study on Force Plate and Customized Weighing Scale, IEEE Journal of Biomedical and Health Informatics, 10.1109/JBHI.2019.2901635, 24:1, (69-78) Shi K, Schellenberger S, Will C, Steigleder T, Michler F, Fuchs J, Weigel R, Ostgathe C and Koelpin A (2020) A dataset of radar-recorded heart sounds and vital signs including synchronised reference sensor signals, Scientific Data, 10.1038/s41597-020-0390-1, 7:1, Online publication date: 1-Dec-2020. Wen X, Huang Y, Wu X and Zhang B A Feasible Feature Extraction Method for Atrial Fibrillation Detection From BCG, IEEE Journal of Biomedical and Health Informatics, 10.1109/JBHI.2019.2927165, 24:4, (1093-1103) Yousefian P, Shin S, Mousavi A, Kim C, Finegan B, McMurtry M, Mukkamala R, Jang D, Kwon U, Kim Y and Hahn J (2019) Physiological Association between Limb Ballistocardiogram and Arterial Blood Pressure Waveforms: A Mathematical Model-Based Analysis, Scientific Reports, 10.1038/s41598-019-41537-y, 9:1, Online publication date: 1-Dec-2019. Wen X, Huang Y, Wu X and Zhang B (2019) A Correlation-Based Algorithm for Beat-to-Beat Heart Rate Estimation from Ballistocardiograms 2019 41st Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), 10.1109/EMBC.2019.8856464, 978-1-5386-1311-5, (6355-6358) Xie Q, Wang M, Zhao Y, He Z, Li Y, Wang G and Lian Y A Personalized Beat-to-Beat Heart Rate Detection System From Ballistocardiogram for Smart Home Applications, IEEE Transactions on Biomedical Circuits and Systems, 10.1109/TBCAS.2019.2957571, 13:6, (1593-1602) Mokhtari S and Al Ahmad M (2019) Portable piezoelectric cardiac abnormality detection, Alexandria Engineering Journal, 10.1016/j.aej.2019.09.008, 58:3, (1053-1061), Online publication date: 1-Sep-2019. He S, Dajani H, Meade R, Kenny G and Bolic M (2019) Continuous Tracking of Changes in Systolic Blood Pressure using BCG and ECG 2019 41st Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), 10.1109/EMBC.2019.8856332, 978-1-5386-1311-5, (6826-6829) Zhang X, Zhang L, Wang K, Yu C, Zhu T and Tang J (2016) A rapid approach to assess cardiac contractility by ballistocardiogram and electrocardiogram, Biomedical Engineering / Biomedizinische Technik, 10.1515/bmt-2015-0204, 63:2, (113-122), Online publication date: 28-Mar-2018., Online publication date: 1-Apr-2018. Nair L and Aparna P (2018) Non-Contact Heart-Rate Measurement Using KLT-Algorithm 2018 Second International Conference on Electronics, Communication and Aerospace Technology (ICECA), 10.1109/ICECA.2018.8474805, 978-1-5386-0965-1, (1944-1947) He S, Li X, Batkin I, Dajani H and Bolic M (2018) Detecting Cardiac Activity by Capacitive Electrodes from a Single Point on the Wrist 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 10.1109/EMBC.2018.8513339, 978-1-5386-3646-6, (3809-3812) Will C, Shi K, Schellenberger S, Steigleder T, Michler F, Fuchs J, Weigel R, Ostgathe C and Koelpin A (2018) Radar-Based Heart Sound Detection, Scientific Reports, 10.1038/s41598-018-29984-5, 8:1, Online publication date: 1-Dec-2018. Ganesan M and Sumesh E (2016) Evaluating the force of contraction of heart using ballistocardiogram 2016 3rd MEC International Conference on Big Data and Smart City (ICBDSC), 10.1109/ICBDSC.2016.7460371, 978-1-5090-1365-4, (1-5) Canino N, Wang R and Robinson C (2016) Using multiple placements of accelerometers to measure cardiovascular pulse transit times 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 10.1109/EMBC.2016.7591665, 978-1-4577-0220-4, (4248-4251) Pinheiro E, Postolache O and Girao P (2016) Ballistocardiogram: Model and sensing systems 2016 10th International Conference on Sensing Technology (ICST), 10.1109/ICSensT.2016.7796262, 978-1-5090-0796-7, (1-6) Martin-Yebra A, Landreani F, Casellato C, Pavan E, Frigo C, Migeotte P and Caiani E (2015) Studying heart rate variability from ballistocardiography acquired by force platform: Comparison with conventional ECG 2015 Computing in Cardiology Conference (CinC), 10.1109/CIC.2015.7411064, 978-1-5090-0685-4, (929-932) Byeong-Gu Ahn , Yun-Hong Noh and Do-Un Jeong (2015) Smart chair based on multi heart rate detection system 2015 IEEE Sensors, 10.1109/ICSENS.2015.7370628, 978-1-4799-8203-5, (1-4) McCall C, Rostosky R, Wiard R, Inan O, Giovangrandi L, Cuttino C and Kovacs G (2015) Noninvasive pulse transit time measurement for arterial stiffness monitoring in microgravity 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 10.1109/EMBC.2015.7319864, 978-1-4244-9271-8, (6429-6432) Srinivasan A, Zhang Haihong , Lin Zhiping , Biswas J and Chen Zhihao (2015) Towards numerical temporal-frequency system modelling of associations between electrocardiogram and ballistocardiogram 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 10.1109/EMBC.2015.7318382, 978-1-4244-9271-8, (394-397) Kim B, Noh Y and Jeong D (2015) Implementation of the Smart Chair System for Multi-functional Unconstrained Healthcare Monitoring 2015 IEEE 29th International Conference on Advanced Information Networking and Applications (AINA), 10.1109/AINA.2015.220, 978-1-4799-7905-9, (448-452) van Rooij B, Tavakolian K, Arzanpour S, Blaber A and Leguy C (2015) Non-invasive estimation of cardiovascular parameters using ballistocardiography 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 10.1109/EMBC.2015.7318593, 978-1-4244-9271-8, (1247-1250) Gomez-Clapers J, Serra-Rocamora A, Casanella R and Pallas-Areny R (2014) Towards the standardization of ballistocardiography systems for J-peak timing measurement, Measurement, 10.1016/j.measurement.2014.09.003, 58, (310-316), Online publication date: 1-Dec-2014. Dziuda Ł and Skibniewski F (2014) A new approach to ballistocardiographic measurements using fibre Bragg grating-based sensors, Biocybernetics and Biomedical Engineering, 10.1016/j.bbe.2014.02.001, 34:2, (101-116), . Hyun E, Noh S, Yoon C and Kim H (2014) Patch type integrated sensor system for measuring electrical and mechanical cardiac activities 2014 IEEE Sensors Applications Symposium (SAS), 10.1109/SAS.2014.6798924, 978-1-4799-2179-9, (94-96) Postolache O, Girão P and Postolache G (2013) Seismocardiogram and Ballistocardiogram Sensing Advanced Instrument Engineering, 10.4018/978-1-4666-4165-5.ch017, (223-246) Luna-Lozano P and Alvarado-Serrano C (2012) Time and amplitude relationships of the ballistocardiogram in vertical and horizontal direction 2012 9th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE 2012), 10.1109/ICEEE.2012.6421181, 978-1-4673-2169-3, (1-6) Vogt E, MacQuarrie D and Neary J (2012) Using ballistocardiography to measure cardiac performance: a brief review of its history and future significance, Clinical Physiology and Functional Imaging, 10.1111/j.1475-097X.2012.01150.x, 32:6, (415-420), Online publication date: 1-Nov-2012. Rosales L, Skubic M, Heise D, Devaney M and Schaumburg M (2012) Heartbeat detection from a hydraulic bed sensor using a clustering approach 2012 34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 10.1109/EMBC.2012.6346443, 978-1-4577-1787-1, (2383-2387) Postolache O, Girão P and Postolache G (2011) Seismocardiogram and Ballistocardiogram Sensing, International Journal of Measurement Technologies and Instrumentation Engineering, 10.4018/ijmtie.2011070106, 1:3, (67-88), Online publication date: 1-Jul-2011. Giovangrandi L, Inan O, Wiard R, Etemadi M and Kovacs G (2011) Ballistocardiography — A method worth revisiting 2011 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 10.1109/IEMBS.2011.6091062, 978-1-4577-1589-1, (4279-4282) Alametsä J, Palomäki A and Viik J (2011) Short and longer term repeatability of ballistocardiography in a sitting position with EMFi sensor, Medical & Biological Engineering & Computing, 10.1007/s11517-011-0746-y, 49:8, (881-889), Online publication date: 1-Aug-2011. Postolache O, Girão P, Pinheiro E and Postolache G (2010) Unobtrusive and Non-invasive Sensing Solutions for On-Line Physiological Parameters Monitoring Wearable and Autonomous Biomedical Devices and Systems for Smart Environment, 10.1007/978-3-642-15687-8_15, (277-314), . Pinheiro E, Postolache O and Girão P Theory and Developments in an Unobtrusive Cardiovascular System Representation: Ballistocardiography, The Open Biomedical Engineering Journal, 10.2174/1874120701004010201, 4:1, (201-216) Inan O, Kovacs G and Giovangrandi L Evaluating the Lower-Body Electromyogram Signal Acquired From the Feet As a Noise Reference for Standing Ballistocardiogram Measurements, IEEE Transactions on Information Technology in Biomedicine, 10.1109/TITB.2010.2044185, 14:5, (1188-1196) Inan O, Etemadi M, Wiard R, Kovacs G and Giovangrandi L (2009) Novel methods for estimating the ballistocardiogram signal using a simultaneously acquired electrocardiogram 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 10.1109/IEMBS.2009.5333709, , (5334-5347) Alametsä J, Värri A, Viik J, Hyttinen J and Palomäki A (2009) Ballistocardiogaphic studies with acceleration and electromechanical film sensors, Medical Engineering & Physics, 10.1016/j.medengphy.2009.07.020, 31:9, (1154-1165), Online publication date: 1-Nov-2009. Delman A, Escher D and Arbeit S (1966) The artificially paced human heart, The American Journal of Cardiology, 10.1016/0002-9149(66)90240-2, 17:4, (504-508), Online publication date: 1-Apr-1966. Richman S and Littmann D (1963) Simultaneous intracardiac catheterization and ballistocardiography, The American Journal of Cardiology, 10.1016/0002-9149(63)90123-1, 11:3, (309-318), Online publication date: 1-Mar-1963. Ungerleider H (1962) The prognostic implications of the electrocardiogram Annals of Life Insurance Medicine, 10.1007/978-3-642-85611-2_6, (131-144), . Gubner R (1962) Systolic hypertension: A pathogenetic entity, The American Journal of Cardiology, 10.1016/0002-9149(62)90139-X, 9:5, (773-776), Online publication date: 1-May-1962. Holzmann M (1960) Die Rhythmusstörungen des Herzens (einschließlich der intramuralen Leitungsstörungen und des Alternans) Rhythmus- und Leitungsstörungen Traumatische Herzschädigungen Erkrankungen des Endokard · Myokard · Perikard · Spezielle Kardiologische Untersuchungsmethoden Erworbene Herzklappenfehler, 10.1007/978-3-642-94788-9_1, (1-461), . Ungerleider H (1960) The prognostic implications of the electrocardiogram∗, The American Journal of Cardiology, 10.1016/0002-9149(60)90033-3, 6:1, (35-44), Online publication date: 1-Jul-1960. Schroeder H and Wendhut G (1960) Über die Resonanz- und Federeigenschaften des menschlichen Körpers, Archiv für Kreislaufforschung, 10.1007/BF02119906, 33:3-4, (177-200), Online publication date: 1-Dec-1960. ROSENBLATT W (1957) Ballistocardiography: Concepts of its Applicability in the Office Practice of Cardiology, Diseases of the Chest, 10.1378/chest.32.4.400, 32:4, (400-412), Online publication date: 1-Oct-1957. Yuceoglu Y, Pordy L, Chesky K and Donoso E (1957) The ballistocardiogram in coarctation of the aorta, American Heart Journal, 10.1016/0002-8703(57)90179-5, 53:3, (447-454), Online publication date: 1-Mar-1957. Wade E, Fulton R and Mackinnon J (1956) THE BALLISTOCARDIOGRAM IN THE DIAGNOSIS OF CORONARY ARTERIAL DISEASE, Heart, 10.1136/hrt.18.1.65, 18:1, (65-77), Online publication date: 1-Jan-1956. Donoso E, Pordy L, Yuceoglu Y, Minor J, Chesky K and Amram S (1956) The ballistocardiogram in congenital heart disease, American Heart Journal, 10.1016/0002-8703(56)90210-1, 52:3, (352-358), Online publication date: 1-Sep-1956. Lusted L (1955) Medical Electronics, New England Journal of Medicine, 10.1056/NEJM195504072521405, 252:14, (580-585), Online publication date: 7-Apr-1955. Scherf D and Boyd L (1955) Anginöse Schmerzen und ihre Differentialdiagnose Klinik und Therapie der Herzkrankheiten und der Gefäßerkrankungen, 10.1007/978-3-7091-7854-6_16, (304-386), . Taylor H, Maloney W and Keys A (1954) Factors affecting the low-frequency, critically-damped ballistocardiogram, with special reference to age, body size, and body composition, American Heart Journal, 10.1016/0002-8703(54)90104-0, 48:6, (864-880), Online publication date: 1-Dec-1954. ABRAMS W and EDGER H (1953) A Ballistocardiographic Study of Healthy Young Adult Males, Circulation, 8:5, (738-743), Online publication date: 1-Nov-1953. Landreani , Faini , Martin-Yebra , Morri , Parati and Caiani (2019) Assessment of Ultra-Short Heart Variability Indices Derived by Smartphone Accelerometers for Stress Detection, Sensors, 10.3390/s19173729, 19:17, (3729) Parchani G, Kumar G, Rao R, Udupa K and Saran V (2022) Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability, Annals of Neurosciences, 10.1177/09727531211063426, (097275312110634) Albukhari A, Lima F and Mescheder U (2019) Bed-Embedded Heart and Respiration Rates Detection by Longitudinal Ballistocardiography and Pattern Recognition, Sensors, 10.3390/s19061451, 19:6, (1451) Siyahjani F, Garcia Molina G, Barr S and Mushtaq F (2022) Performance Evaluation of a Smart Bed Technology against Polysomnography, Sensors, 10.3390/s22072605, 22:7, (2605) Martín-Yebra A, Landreani F, Casellato C, Pavan E, Migeotte P, Frigo C, Martínez J and Caiani E (2017) Evaluation of respiratory- and postural-induced changes on the ballistocardiogram signal by time warping averaging, Physiological Measurement, 10.1088/1361-6579/aa72b0, 38:7, (1426-1440) February 1, 1953Vol 7, Issue 2 Advertisement Article InformationMetrics © 1953 American Heart Association, Inc.https://doi.org/10.1161/01.CIR.7.2.268 Originally publishedFebruary 1, 1953 PDF download Advertisement

Referência(s)
Altmetric
PlumX