Artigo Acesso aberto Revisado por pares

Doppler flow velocity waveforms in the fetal cardiac outflow tract: Reproducibility of waveform recording and analysis

1991; Elsevier BV; Volume: 17; Issue: 6 Linguagem: Inglês

10.1016/0301-5629(91)90028-u

ISSN

1879-291X

Autores

Irene A.L. Groenenberg, Wim C.J. Hop, J. W. Wladimiroff,

Tópico(s)

Cardiac Arrhythmias and Treatments

Resumo

Reproducibility of flow velocity waveform recording and analysis was studied at fetal cardiac level (ductus arteriosus, pulmonary artery and ascending aorta) in 42 normal pregnancies.The flow velocity parameters studied were the peak systolic velocity (PSV), acceleration time (ACT), acceleration velocity (ACV), average velocity (AV) and flow velocity integral (FVI).In each patient, two consecutive measurements were performed (time delay 15 min) and of each measurement two hardcopies were analysed.A high reproducibility was achieved for the PSV, AV and FV! in all vessels studied; the coefficients of variation between readings of hardcopies were _<3%, and the coefficients of variation between tests within patients were <7%.A moderate reproducibility was achieved for the ACT in the ascending aorta and pulmonary artery; the variation between tests was large for the ductus arteriosus.The reproducibility of the ACV was poor.

Referência(s)