Line width measurement of a capillary discharge soft x-ray laser

2011; SPIE; Volume: 8140; Linguagem: Inglês

10.1117/12.892929

ISSN

1996-756X

Autores

Ł. Urbański, Lei Meng, Mario C. Marconi, M. Berril, Olivier Guilbaud, A. Klisnick, J. J. Rocca,

Tópico(s)

X-ray Spectroscopy and Fluorescence Analysis

Resumo

We measured the linewidth of a λ= 46.9 nm neon-like argon capillary discharge soft x-ray laser. A wavefront division interferometer based on a pair of dihedrons was used to resolve the laser line measuring the variation in the interference fringe visibility for different optical path differences. We measured a relative linewidths of Δλ/λ = 3-4 10 -5 . No significant re-broadening was observed when the length of the laser medium was increased beyond the saturation length due to effects that homogenizes the line profile.