CALIBRAÇÃO DE PRISMAS DE REFLEXÃO TOTAL EM FORMA DE FITA ADESIVA, EM ACRÍLICO E SUA APLICAÇÃO NO CONTROLE DE DESLOCAMENTOS DE ESTRUTURAS
2005; UNIVERSIDADE FEDERAL DO PARANÁ; Volume: 11; Issue: 2 Linguagem: Inglês
ISSN
1982-2170
Autores Tópico(s)Optics and Image Analysis
ResumoThe present work presents a study about the calibration of prisms that use the principle of total reflection (reflector tape and acrylic one) and the application of these in the monitoring of structures displacements. Were determined the constants of these reflectors, the maximum rotation angles of these in relation to the collimation line and the variation in the size of targets reflector tape done with as a function of the distance between the total station and the point of interest. All the studies were carried through in two distinct environments: The Laboratorio de Instrumentacao Geodesica (LAIG) and the Linear Base for Calibration of Total Stations, located in the Canguiri Farm, that belongs to Univerdsidade Federal do Parana (UFPR). Its important to stand out that all the experiments had as standard for the comparison of the results, the Laser Interferometer HP 5518A, available in the LAIG and the LEICA GPH1P prism, with the reflector constant equal to 0 mm. For the evaluation of the use of these prisms in the monitoring of structures displacements, a set of points locate in the Salto Caxias Dam ( in the Capitao Leonidas Marques city, Parana state) were monitored in diferents epochs using it total station ELTA S20. It were analyzed the question of the durability of the reflector tapes when exposed to atmospheric conditions.
Referência(s)