Determination of Hardness and Young's Modulus of Brush Plated Nano-AL 2 O 3 /NI Composite Coating by Nanoindentation Testing
2003; Maney Publishing; Volume: 19; Issue: 3 Linguagem: Inglês
10.1179/026708403225006168
ISSN1743-2944
AutoresSuchuan Dong, Ben D. Beake, R. D. Parkinson, Trevor Bell,
Tópico(s)Tribology and Wear Analysis
ResumoNanoindentation was used to produce maps of the hardness and elastic modulus through cross-sections of a brush plated nanoparticle composite n-Al 2 O 3 /Ni coating on mild carbon steel. The Young's modulus of the brush plated n-Al 2 O 3 /Ni composite coating was ∼200 GPa. The coating exhibited uniform mechanical properties throughout its thickness, with the exception of a few regions with low hardness and modulus due to pores and microcracks. It is essential to control the selective plating process to reduce the defect content and ensure uniform properties of the nanoparticle composite coatings.
Referência(s)