Artigo Revisado por pares

Attrition of coal ash particles in a fluidized bed

1991; Elsevier BV; Volume: 66; Issue: 1 Linguagem: Inglês

10.1016/0032-5910(91)80079-x

ISSN

1873-328X

Autores

J.J. Pís, Antonio B. Fuertes, V. Artos, Ana Beatriz García Suárez, F. Rubiera,

Tópico(s)

Iron and Steelmaking Processes

Resumo

In this work, an attrition study has been carried out using a fluidized bed of coal ash. Experiments were carried out in a cold fluidized bed 0.14 m in diameter and 2.20 m in height. The effect on attrition of the following variables has been studied: bed particle size, static height of bed, time of attrition and fluidizing velocity. It was concluded that attrition is mainly due to abrasion, resulting in the removal of fines of a size smaller than 50 μm. The size distribution of fines produced is independent of the original particle sizes. The attrition rate varies linearly with the parameter (U – Uo). It was observed that the variation of the static bed height has no effect on the attrition rate under steady-state conditions.

Referência(s)
Altmetric
PlumX