Artigo Revisado por pares

Ist die Verwendung des Knee Society Roentgenographic Evaluation and Scoring System zur radiologischen Kontrolle von Knieendoprothesen sinnvoll?

2008; Thieme Medical Publishers (Germany); Volume: 136; Issue: 01 Linguagem: Inglês

10.1055/s-2008-1044654

ISSN

1438-941X

Autores

A. König, Matthias Scheidler, C. Räder, Matthias Haase, J. Eulert,

Tópico(s)

Musculoskeletal Disorders and Rehabilitation

Resumo

To follow the radiographic parameters of prosthetic loosening of the Knee Society Roentgenographic Evaluation and Scoring System (KSRESS) and to test their clinical relevance.This prospective study documents the use of the KSRESS and clinical rating system in 333 primary posterior cruciate retaining PFC total knee arthroplasties preoperatively, at 3 month and at yearly intervals postoperatively. The average follow-up period was 3.2 years (range 2-5.5 y).The average component position and alignment angles remained unchanged at biomechanically correct angles during the follow-up period. Radiolucent lines were observed regularly at the edges of the tibial and femoral components. The average total radiolucent lines score decreased for the tibial component. Patellar and femoral lucencies remained unchanged. The total radiolucent lines scores did not correlate with postoperative pain, body-mass-index, alignment, stability, knee and function score. Four revisions, one with relevant radiolucent lines, had to be performed.The KSRESS is a useful tool. Standardisation of roentgenograms is mandatory. The PFC arthroplasty, the operative technique and the instruments ensure a biomechanically correct implantation.

Referência(s)