Artigo Revisado por pares

Test facility for investigation of heating of 30GHz accelerating structure imitator for the CLIC project

2004; Elsevier BV; Volume: 528; Issue: 1-2 Linguagem: Inglês

10.1016/j.nima.2004.04.052

ISSN

1872-9576

Autores

A. V. Elzhov, N. S. Ginzburg, A. K. Kaminsky, S. V. Kuzikov, É. A. Perelstein, N. Yu. Peskov, M. I. Petelin, S. N. Sedykh, A. P. Sergeev, A. S. Sergeev, Igor Syratchev, N. I. Zaitsev,

Tópico(s)

Particle accelerators and beam dynamics

Resumo

Abstract Since 2001 an experimental test facility for investigation of lifetime of a copper material, with respect to multiple RF pulse actions, was set up on the basis of the JINR (Dubna) FEM oscillator, in collaboration with IAP RAS (Nizhny Novgorod). A high- Q copper cavity, which simulates the parameters of the accelerating structure of the collider CLIC at an operating frequency of 30 GHz, is used in the investigation. The experimental setup consists of a wavebeam injector—FEM oscillator (power of ∼25 MW, pulse duration up to 200 ns, spectral bandwidth not higher than 0.1%), a quasi-optic two-mirror transmission line, a wave-type converter, and a testing cavity. The frequency and transmission features of the components of the quasi-optic line were analyzed.

Referência(s)