Carta Revisado por pares

Is MR-guided Attenuation Correction a Viable Option for Dual-Modality PET/MR Imaging?

2007; Radiological Society of North America; Volume: 244; Issue: 3 Linguagem: Inglês

10.1148/radiol.2443070092

ISSN

1527-1315

Autores

Habib Zaidi,

Tópico(s)

Nuclear Physics and Applications

Resumo

HomeRadiologyVol. 244, No. 3 PreviousNext Reviews and CommentaryEditorialsIs MR-guided Attenuation Correction a Viable Option for Dual-Modality PET/MR Imaging?Habib ZaidiHabib ZaidiAuthor Affiliations1From the Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva 4, Switzerland. Received January 23, 2007; revision requested March 1; revision received March 2; final version accepted March 19.Address correspondence to the author (e-mail: [email protected]).Habib ZaidiPublished Online:Sep 1 2007https://doi.org/10.1148/radiol.2443070092MoreSectionsFull textPDF ToolsAdd to favoritesCiteTrack CitationsPermissionsReprints ShareShare onFacebookXLinked In References1 Judenhofer MS, Catana C, Swann BK, et al. PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet. Radiology 2007;244:(3)807–814. Link, Google Scholar2 Shao Y, Cherry SR, Farahani K, Meadors K. Simultaneous PET and MR imaging. Phys Med Biol 1997;42:1965–1970. Crossref, Medline, Google Scholar3 Mackewn JE, Strul D, Hallett WA, et al. Design and development of an MR-compatible PET scanner for imaging small animals. IEEE Trans Nucl Sci 2005;52:1376–1380. Crossref, Google Scholar4 Raylman RR, Majewski S, Lemieux SK, et al. Simultaneous MRI and PET imaging of a rat brain. Phys Med Biol 2006;51:6371–6379. Crossref, Medline, Google Scholar5 Lucas AJ, Hawkes RC, Ansorge RE, et al. Development of a combined microPET-MR system. Technol Cancer Res Treat 2006;5:337–341. Crossref, Medline, Google Scholar6 Catana C, Wu Y, Judenhofer MS, Qi J, Pichler BJ, Cherry SR. Simultaneous acquisition of multislice PET and MR images: initial results with an MR-compatible PET scanner. J Nucl Med 2006;47:1968–1976. Medline, Google Scholar7 Handler WB, Gilbert KM, Peng H, Chronik BA. Simulation of scattering and attenuation of 511 keV photons in a combined PET/field-cycled MRI system. Phys Med Biol 2006;51:2479–2491. Crossref, Medline, Google Scholar8 Burbar Z, Grazioso RF, Corbeil J, et al. PET performance of MR/PET brain insert tomograph [abstr]. In: Proceedings of the IEEE Nuclear Science Symposium and Medical Imaging Conference, San Diego, Calif. San Diego, Calif: IEEE, 2006;116. Google Scholar9 Wagenaar DJ, Kapusta M, Li J, Patt BE. Rationale for the combination of nuclear medicine with magnetic resonance for pre-clinical imaging. Technol Cancer Res Treat 2006;5:343–350. Crossref, Medline, Google Scholar10 Beyer T, Townsend D. Putting 'clear' into nuclear medicine: a decade of PET/CT development. Eur J Nucl Med Mol Imaging 2006;33:857–861. Crossref, Medline, Google Scholar11 Alavi A, Mavi A, Basu S, Fischman A. Is PET-CT the only option? Eur J Nucl Med Mol Imaging 2007;34:819–821. Google Scholar12 Seemann MD. Whole-body PET/MRI: the future in oncological imaging. Technol Cancer Res Treat 2005;4:577–582. Crossref, Medline, Google Scholar13 Hu X, Norris DG. Advances in high-field magnetic resonance imaging. Annu Rev Biomed Eng 2004;6:157–184. Crossref, Medline, Google Scholar14 Zaidi H, Montandon ML, Meikle S. Strategies for attenuation compensation in neurological PET studies. Neuroimage 2007;34:518–541. Crossref, Medline, Google Scholar15 Zaidi H, Montandon ML, Slosman DO. Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. Med Phys 2003;30:937–948. Crossref, Medline, Google Scholar16 Zaidi H. Is radionuclide transmission scanning obsolete for dual-modality PET/CT systems? Eur J Nucl Med Mol Imaging 2007;34:815–818. Google Scholar17 Zaidi H. Medical image segmentation: quo vadis. Comput Methods Programs Biomed 2006;84:63–67. Crossref, Medline, Google Scholar18 Rowell NP, Glaholm J, Flower MA, Cronin B, McCready VR. Anatomically derived attenuation coefficients for use in quantitative single photon emission tomography studies of the thorax. Eur J Nucl Med 1992;19:36–40. Medline, Google Scholar19 El Fakhri G, Kijewski MF, Moore SC. Absolute activity quantitation from projections using an analytical approach: comparison with iterative methods in Tc-99m and I-123 brain SPECT. IEEE Trans Nucl Sci 2001;48:768–773. Crossref, Google Scholar20 International Commission on Radiological Units and Measurements. Tissue substitutes in radiation dosimetry and measurement. Bethesda, Md: International Commission on Radiological Units and Measurements, 1989. Google Scholar21 Dogdas B, Shattuck DW, Leahy RM. Segmentation of skull and scalp in 3-D human MRI using mathematical morphology. Hum Brain Mapp 2005;26:273–285. Crossref, Medline, Google Scholar22 Braem A, Llatas MC, Chesi E, et al. Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research. Phys Med Biol 2004;49:2547–2562. Crossref, Medline, Google Scholar23 Robson MD, Bydder GM. Clinical ultrashort echo time imaging of bone and other connective tissues. NMR Biomed 2006;19:765–780. Crossref, Medline, Google Scholar24 Rust TC, Kadrmas DJ. Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study. Phys Med Biol 2006;51:61–75. Crossref, Medline, Google Scholar25 Ray N, Acton ST, Altes T, de Lange EE, Brookeman JR. Merging parametric active contours within homogeneous image regions for MRI-based lung segmentation. IEEE Trans Med Imaging 2003;22:189–199. Crossref, Medline, Google Scholar26 Sensakovic WF, Armato SG 3rd, Starkey A, Caligiuri P. Automated lung segmentation of diseased and artifact-corrupted magnetic resonance sections. Med Phys 2006;33:3085–3093. Crossref, Medline, Google Scholar27 Lelieveldt BP, van der Geest RJ, Rezaee MR, Bosch JG, Reiber JH. Anatomical model matching with fuzzy implicit surfaces for segmentation of thoracic volume scans. IEEE Trans Med Imaging 1999;18:218–230. Crossref, Medline, Google Scholar28 Robinson PJ, Kreel L. Pulmonary tissue attenuation with computed tomography: comparison of inspiration and expiration scans. J Comput Assist Tomogr 1979;3:740–748. Crossref, Medline, Google Scholar29 Montandon ML, Zaidi H. Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging. Neuroimage 2005;25:278–286. Crossref, Medline, Google Scholar30 Hofmann M, Steinke F, Judenhofer MS, Claussen CD, Schoelkopf B, Pichler BJ. A machine learning approach for determining the PET attenuation map from magnetic resonance images [abstr]. In: Proceedings of the IEEE Nuclear Science Symposium and Medical Imaging Conference, San Diego, Calif. San Diego, Calif: IEEE, 2006;115. Google Scholar31 Zaidi H, Mawlawi O. Simultaneous PET/NMR will replace PET/CT as the molecular multimodality imaging platform of choice. Med Phys 2007;34:1525–1528. Crossref, Medline, Google ScholarArticle HistoryPublished in print: 2007 FiguresReferencesRelatedDetailsCited ByHybrid PET/MR NeuroimagingMinosKritikos, Sean A. P.Clouston2022Advances in ImagingSikandarShaikh2022Recent Results in Cancer ResearchDiego AlfonsoLópez-Mora, Luis AlarcónLagos, MontserratEstorch, IgnasiCarrio2020 | , Vol. 216Metal artifact correction strategies in MRI-based attenuation correction in PET/MRIGeorgSchramm, Claes NøhrLadefoged2019 | BJR|Open, Vol. 1, No. 1Workflow and Protocol ConsiderationsAmbrosBeer, PatrickVeit-Haibach24 January 2018Single STE-MR Acquisition in MR-Based Attenuation Correction of Brain PET Imaging Employing a Fully Automated and Reproducible Level-Set Segmentation ApproachAnahitaFathi Kazerooni, Mohammad RezaAy, SamanArfaie, ParisaKhateri, HamidrezaSaligheh Rad2017 | Molecular Imaging and Biology, Vol. 19, No. 1Downstream indication to revascularization following hybrid cardiac PET/MRIJulienPriamo, DionysosAdamopoulos, OlivierRager, AngelaFrei, StephaneNoble, DavidCarballo, OsmanRatib, RenéNkoulou2017 | Nuclear Medicine Communications, Vol. 38, No. 6Attenuation correction in emission tomography using the emission data—A reviewYannickBerker, YushengLi14 January 2016 | Medical Physics, Vol. 43, No. 2The Promise of Hybrid PET\/MRI: Technical advances and clinical applicationsHabibZaidi, MinervaBecker2016 | IEEE Signal Processing Magazine, Vol. 33, No. 3Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRIAbolfazlMehranian, HosseinArabi, HabibZaidi2016 | NeuroImage, Vol. 130Vision 20/20: Magnetic resonance imaging‐guided attenuation correction in PET/MRI: Challenges, solutions, and opportunitiesAbolfazlMehranian, HosseinArabi, HabibZaidi2016 | Medical Physics, Vol. 43, No. 3Probabilistic Air Segmentation and Sparse Regression Estimated Pseudo CT for PET/MR Attenuation CorrectionYasheng Chen, Meher Juttukonda, Yi Su, Tammie Benzinger, Brian G. Rubin, Yueh Z. Lee, Weili Lin, Dinggang Shen, David Lalush, Hongyu An, 17 December 2014 | Radiology, Vol. 275, No. 2Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correctionUlrikeAttenberger, CiprianCatana, HershChandarana, Onofrio ACatalano, KentFriedman, Stefan ASchonberg, JamesThrall, MarcoSalvatore, Bruce R.Rosen, Alexander R.Guimaraes2015 | Abdominal Imaging, Vol. 40, No. 6Clinical Assessment of MR-Guided 3-Class and 4-Class Attenuation Correction in PET/MRHosseinArabi, OlivierRager, AsmaAlem, ArthurVaroquaux, MinervaBecker, HabibZaidi2015 | Molecular Imaging and Biology, Vol. 17, No. 2Emission-based estimation of lung attenuation coefficients for attenuation correction in time-of-flight PET/MRAbolfazlMehranian, HabibZaidi2015 | Physics in Medicine and Biology, Vol. 60, No. 12Joint Estimation of Activity and Attenuation in Whole-Body TOF PET/MRI Using Constrained Gaussian Mixture ModelsAbolfazlMehranian, HabibZaidi2015 | IEEE Transactions on Medical Imaging, Vol. 34, No. 9Hybrid PET/MR Imaging: An Algorithm to Reduce Metal Artifacts from Dental Implants in Dixon-Based Attenuation Map Generation Using a Multiacquisition Variable-Resonance Image Combination SequenceIrene A.Burger, Moritz C.Wurnig, Anton S.Becker, DavidKenkel, GasparDelso, PatrickVeit-Haibach, AndreasBoss2015 | Journal of Nuclear Medicine, Vol. 56, No. 1Impact of Time-of-Flight PET on Quantification Errors in MR Imaging–Based Attenuation CorrectionAbolfazlMehranian, HabibZaidi2015 | Journal of Nuclear Medicine, Vol. 56, No. 4Classification of bones from MR images in torso PET-MR imaging using a statistical shape modelMohammadReza Ay, AfshinAkbarzadeh, AlirezaAhmadian, HabibZaidi2014 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 734Measurement of SUVs-Maximum for Normal Region Using VOI in PET/MRI and PET/CTJeong KyuPark, Sung KyuKim, Ihn HoCho, Eun JungKong2014 | The Scientific World Journal, Vol. 2014Imaging in head and neck squamous cell carcinoma: the potential role of PET/MRIMinervaBecker, HabibZaidi2014 | The British Journal of Radiology, Vol. 87, No. 1036Workflow Considerations in PET/MR ImagingGustav K.von Schulthess, PatrickVeit-Haibach2014 | Journal of Nuclear Medicine, Vol. 55, No. Supplement 2Anatomic Evaluation of 3-Dimensional Ultrashort-Echo-Time Bone Maps for PET/MR Attenuation CorrectionGasparDelso, MichaelCarl, FlorianWiesinger, LauraSacolick, MiguelPorto, MartinHüllner, AndreasBoss, PatrickVeit-Haibach2014 | Journal of Nuclear Medicine, Vol. 55, No. 5Molecular Imaging of Small AnimalsHabibZaidi2014Molecular Imaging of Small AnimalsDavidSchlyer, BoskyRavindranath2014Radiological Safety and QualityDaniel F.Gutierrez, HabibZaidi2014State of the Art: Advanced Imaging of the Right Ventricle and Pulmonary Circulation in Humans (2013 Grover Conference Series)Mariëlle C.van de Veerdonk, J. TimMarcus, Harm‐JanBogaard, Anton VonkNoordegraaf2014 | Pulmonary Circulation, Vol. 4, No. 2Dual-Modality Preclinical SPECT/MRI InstrumentationDouglas J.Wagenaar, DirkMeier, Bradley E.Patt29 April 2014Recent Results in Cancer ResearchDanielaThorwarth, Arndt-ChristianMüller, ChristinaPfannenberg, ThomasBeyer2013 | , Vol. 194Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomenFelix P.Kuhn, David W.Crook, Caecilia E.Mader, PhilippeAppenzeller, G. K.von Schulthess, Daniel T.Schmid2013 | European Journal of Nuclear Medicine and Molecular Imaging, Vol. 40, No. 1Challenges and current methods for attenuation correction in PET/MRVincentKeereman, PieterMollet, YannickBerker, VolkmarSchulz, StefaanVandenberghe2013 | Magnetic Resonance Materials in Physics, Biology and Medicine, Vol. 26, No. 1Comparison of Standardized Uptake Values in Normal Structures Between PET/CT and PET/MRI in an Oncology Patient PopulationSharifKershah, SasanPartovi, Bryan JTraughber, Raymond F.Muzic, Mark DSchluchter, James KO'Donnell, PeterFaulhaber2013 | Molecular Imaging and Biology, Vol. 15, No. 6MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuationA.Akbarzadeh, M. R.Ay, A.Ahmadian, N.Riahi Alam, H.Zaidi2013 | Annals of Nuclear Medicine, Vol. 27, No. 2Novel Quantitative Techniques in Hybrid (PET-MR) Imaging of Brain TumorsSrinivasanSenthamizhchelvan, HabibZaidi2013 | PET Clinics, Vol. 8, No. 2Motion Artifacts in Oncological and Cardiac PET ImagingJuliaDinges, Stephan G.Nekolla, Ralph A.Bundschuh2013 | PET Clinics, Vol. 8, No. 1Pulmonary vascular remodeling and right heart failure in pulmonary hypertension: future role of positron emission tomography in decoding the enigmaHendrik JHarms, Mariëlle Cvan de Veerdonk, Adriaan ALammertsma, Anton VonkNoordegraaf, Harm JanBogaard2013 | Translational Respiratory Medicine, Vol. 1, No. 1Image Evaluation Via SUVLBMfor Normal Regions of VOI by Using Whole Body Images Obtained from PET/MRI and PET/CTJeong KyuPark, Sung KyuKim, Ihn HoCho, Eun JungKong, Meyong HwanPark2013 | Progress in Medical Physics, Vol. 24, No. 1Recent Results in Cancer ResearchMontserratEstorch, IgnasiCarrio2013 | , Vol. 187Voxel‐wise uncertainty in CT substitute derived from MRIAdamJohansson, MikaelKarlsson, JunYu, ThomasAsklund, TufveNyholm22 May 2012 | Medical Physics, Vol. 39, No. 6Part1First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic DiagnosesAlexanderDrzezga, MichaelSouvatzoglou, MatthiasEiber, Ambros J.Beer, SebastianFürst, AxelMartinez-Möller, Stephan G.Nekolla, SibylleZiegler, CarlGanter, Ernst J.Rummeny, MarkusSchwaiger2012 | Journal of Nuclear Medicine, Vol. 53, No. 6Workflow and Scan Protocol Considerations for Integrated Whole-Body PET/MRI in OncologyAxelMartinez-Möller, MatthiasEiber, Stephan G.Nekolla, MichaelSouvatzoglou, AlexanderDrzezga, SibylleZiegler, Ernst J.Rummeny, MarkusSchwaiger, Ambros J.Beer2012 | Journal of Nuclear Medicine, Vol. 53, No. 9Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR dataV.Schulz, I.Torres-Espallardo, S.Renisch, Z.Hu, N.Ojha, P.Börnert, M.Perkuhn, T.Niendorf, W. M.Schäfer, H.Brockmann, T.Krohn, A.Buhl, R. W.Günther, F. M.Mottaghy, G. A.Krombach2011 | European Journal of Nuclear Medicine and Molecular Imaging, Vol. 38, No. 1Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesionsMatthiasEiber, AxelMartinez-Möller, MichaelSouvatzoglou, KonstantinHolzapfel, AnjaPickhard, DennysLöffelbein, IvanSanti, Ernst J.Rummeny, SibylleZiegler, MarkusSchwaiger, Stephan G.Nekolla, Ambros J.Beer2011 | European Journal of Nuclear Medicine and Molecular Imaging, Vol. 38, No. 9Comparative Assessment of Energy-Mapping Approaches in CT-Based Attenuation Correction for PETMohammad R.Ay, MaryamShirmohammad, SaeedSarkar, ArmanRahmim, HabibZaidi2011 | Molecular Imaging and Biology, Vol. 13, No. 1The future of hybrid imaging—part 3: PET/MR, small-animal imaging and beyondThomasBeyer, Lutz S.Freudenberg, JohannesCzernin, David W.Townsend2011 | Insights into Imaging, Vol. 2, No. 3Rational chemical design of the next generation of molecular imaging probes based on physics and biology: mixing modalities, colors and signalsHisatakaKobayashi, Michelle R.Longmire, MikakoOgawa, Peter L.Choyke2011 | Chemical Society Reviews, Vol. 40, No. 9Design and performance evaluation of a whole-body Ingenuity TF PET–MRI systemHZaidi, NOjha, MMorich, JGriesmer, ZHu, PManiawski, ORatib, DIzquierdo-Garcia, Z AFayad, LShao2011 | Physics in Medicine and Biology, Vol. 56, No. 102011 IEEE Nuclear Science Symposium Conference RecordTingtingChang, John W.Clark, Osama R.Mawlawi2011An outlook on future design of hybrid PET/MRI systemsHabibZaidi, AlbertoDel Guerra2011 | Medical Physics, Vol. 38, No. 10The effect of limited MR field of view in MR/PET attenuation correctionGasparDelso, AxelMartinez-Möller, Ralph A.Bundschuh, Stephan G.Nekolla, Sibylle I.Ziegler20 May 2010 | Medical Physics, Vol. 37, No. 6Part1MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registrationEduardSchreibmann, Jonathon A.Nye, David M.Schuster, Diego R.Martin, JohnVotaw, TimFox21 April 2010 | Medical Physics, Vol. 37, No. 5The Clinical Role of Fusion Imaging Using PET, CT, and MR ImagingHabibZaidi, Marie-LouiseMontandon, AbassAlavi2010 | Magnetic Resonance Imaging Clinics of North America, Vol. 18, No. 1Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scannerGDelso, AMartinez-Möller, R ABundschuh, RLadebeck, YCandidus, DFaul, S IZiegler2010 | Physics in Medicine and Biology, Vol. 55, No. 15Switching on the Lights for Real-Time Multimodality Tumor Neuroimaging: The Integrated Positron-Emission Tomography/MR Imaging System: Fig 1.S.Bisdas, T.Nägele, H.-P.Schlemmer, A.Boss, C.D.Claussen, B.Pichler, U.Ernemann2010 | American Journal of Neuroradiology, Vol. 31, No. 4Molecular PET/CT Imaging-Guided Radiation Therapy Treatment PlanningHabibZaidi, HansjörgVees, MichaelWissmeyer2009 | Academic Radiology, Vol. 16, No. 9Multimodality Imaging: Beyond PET/CT and SPECT/CTSimon R.Cherry2009 | Seminars in Nuclear Medicine, Vol. 39, No. 5Nonrigid Registration of Joint Histograms for Intensity Standardization in Magnetic Resonance ImagingF.Jager, J.Hornegger2009 | IEEE Transactions on Medical Imaging, Vol. 28, No. 1Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT DataAxelMartinez-Möller, MichaelSouvatzoglou, GasparDelso, Ralph A.Bundschuh, ChristopheChefd'hotel, Sibylle I.Ziegler, NassirNavab, MarkusSchwaiger, Stephan G.Nekolla2009 | Journal of Nuclear Medicine, Vol. 50, No. 4Optimisation of protocol for low dose CT-derived attenuation correction in myocardial perfusion SPECT imagingRainerPreuss, ReinerWeise, OliverLindner, EvaFricke, HaraldFricke, WolfgangBurchert2008 | European Journal of Nuclear Medicine and Molecular Imaging, Vol. 35, No. 6Imagerie par résonance magnétique dans l'évaluation du tube digestifG.Schmutz, V.Lepennec, V.Do, J.Chenard, M.Lepage, J.Lecours2008 | EMC - Radiologie et imagerie médicale - Abdominale - Digestive, Vol. 3, No. 2Preclinical Multimodality Imaging in VivoDavid B.Stout, HabibZaidi2008 | PET Clinics, Vol. 3, No. 3The Clinical Role of Fusion Imaging Using PET, CT, and MR ImagingHabibZaidi, Marie-LouiseMontandon, AbassAlavi2008 | PET Clinics, Vol. 3, No. 3Multimodality imaging of structure and functionD WTownsend2008 | Physics in Medicine and Biology, Vol. 53, No. 4PET versus SPECT: strengths, limitations and challengesArmanRahmim, HabibZaidi2008 | Nuclear Medicine Communications, Vol. 29, No. 32008 IEEE Nuclear Science Symposium Conference RecordVincentKeereman, StefaanVandenberghe, YvesDe Deene, RobertLuypaert, TomBroux, IgnaceLemahieu2008MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas RegistrationMatthiasHofmann, FlorianSteinke, VerenaScheel, GuillaumeCharpiat, JasonFarquhar, PhilipAschoff, MichaelBrady, BernhardSchölkopf, Bernd J.Pichler2008 | Journal of Nuclear Medicine, Vol. 49, No. 11Latest Advances in Molecular Imaging InstrumentationBernd J.Pichler, Hans F.Wehrl, Martin S.Judenhofer2008 | Journal of Nuclear Medicine, Vol. 49, No. Suppl 2Advances in Attenuation Correction Techniques in PETHabibZaidi, Marie-LouiseMontandon, AbassAlavi2007 | PET Clinics, Vol. 2, No. 2Recommended Articles Deep Learning MR Imaging–based Attenuation Correction for PET/MR ImagingRadiology2017Volume: 286Issue: 2pp. 676-684Quantitative Evaluation of Atlas-based Attenuation Correction for Brain PET in an Integrated Time-of-Flight PET/MR Imaging SystemRadiology2017Volume: 284Issue: 1pp. 169-179U.S. PET/CT and Gamma Camera Diagnostic Reference Levels and Achievable Administered Activities for Noncardiac Nuclear Medicine StudiesRadiology2019Volume: 293Issue: 1pp. 203-211How Imaging Advances Are Defining the Future of Precision Radiation TherapyRadioGraphics2024Volume: 44Issue: 2Head and Neck Paragangliomas: An Update on the Molecular Classification, State-of-the-Art Imaging, and Management RecommendationsRadiology: Imaging Cancer2022Volume: 4Issue: 3See More RSNA Education Exhibits Head Bumps: What Could Be Inside?Digital Posters2020Integrating Molecular Imaging to Meningiomas: Is PET with Somatostatin Receptors Our New Buddy?Digital Posters2022Hepatobiliary And Pancreatic Applications Of PET/MRIDigital Posters2021 RSNA Case Collection Primary Calvarial Lymphoma RSNA Case Collection2021Primary intraosseous meningiomaRSNA Case Collection2020Ewing's sarcomaRSNA Case Collection2020 Vol. 244, No. 3 Metrics Altmetric Score PDF download

Referência(s)
Altmetric
PlumX