Artigo Revisado por pares

DISINTEGRATION-RATE DETERMINATION BY 4π-COUNTING: PART IV. SELF-ABSORPTION CORRECTION: GENERAL METHOD AND APPLICATION TO Ni 63 β-RADIATION

1956; NRC Research Press; Volume: 34; Issue: 3 Linguagem: Inglês

10.1139/v56-040

ISSN

1480-3291

Autores

Brian D. Pate, L. Yaffe,

Tópico(s)

Medical Imaging Techniques and Applications

Resumo

A method of preparing thin uniform sources of radioactive materials for use in a 4π counter is described. The radioactive nuclides are formed into organic compounds and are subsequently distilled on to thin VYNS films. Electron microscope photographs of the deposits are shown. The material is uniformly deposited in crystals of about 1 μ in diameter. The distillation can be rendered quantitative. The amount of material on the film can be estimated either spectrophotometrically in situ or by appropriate chemical means. Using this method a self-absorption curve for Ni 63 (maximum beta energy 67 kev.) is obtained.

Referência(s)
Altmetric
PlumX