Speciation of Aluminum in Rainwater Using a Fluoride Ion-Selective Electrode and Ion-Exchange Chromatography with Fluorometric Detection of the Aluminum−Lumogallion Complex

2001; American Chemical Society; Volume: 73; Issue: 22 Linguagem: Inglês

10.1021/ac010428w

ISSN

1520-6882

Autores

Hirokazu Hara, Hidemasa Kobayashi, Mayumi Maeda, Ai Ueno, Yohko Kobayashi,

Tópico(s)

Chemical Analysis and Environmental Impact

Resumo

Soluble aluminum in rainwater was separated into three categories: free aluminum (Al3+), fluoride complexes (sum of AlF2+ and AlF2+), and other forms of aluminum. The free form of the aluminum ion (Al3+) was directly obtained from the separation data of aluminum species according to their charge using gradient elution cation-exchange chromatography. The aluminum fluoride complexes were estimated by combining the data of the free and total fluoride determined using a fluoride ion-selective electrode, with the assumption that 2+ charged aluminum species consisted only of AlF2+. The rest of the aluminum species had a 1+, neutral, or negative charge and mainly consisted of organic complexes. The origin of the organically bound aluminum is discussed. The concentration range of the total dissolved fluoride and aluminum in the rainwater samples was usually in the micromolar to submicromolar range, and the ratio of [T-F]/[T-Al] was found to be between 1 and 4. The speciation of dissolved aluminum into three categories was carried out on the basis of data of 15 rainwater samples collected in the city of Otsu.