Detection of gunpowder stabilizers with ion mobility spectrometry
2006; Elsevier BV; Volume: 166; Issue: 2-3 Linguagem: Inglês
10.1016/j.forsciint.2006.04.004
ISSN1872-6283
AutoresCaroline West, Giovanna Baron, J. Minet,
Tópico(s)Forensic Fingerprint Detection Methods
ResumoThis study is the first reported ion mobility detection of ethyl centralite and diphenylamine (DPA) smokeless gunpowder stabilizers, together with the nitroso and nitro derivatives of diphenylamine. First, the applicability of the ion mobility spectrometry (IMS) for the substances of interest was determined. The existence of numerous peaks, both in positive and negative modes, clearly demonstrates the success of these experiments. All mono and di-nitro derivatives of DPA tested were detected with this method. Unfortunately, many of the ions generated were not accurately identified. However, reduced mobility constants representative of each ion generated under defined operating conditions could be used for purpose of compound identification. The method was then successfully tested on real gunpowder samples. By the use of IMS, we managed to establish a rapid, simple and sensitive screening method for the detection and identification of smokeless gunpowder organic components.
Referência(s)