Artigo Revisado por pares

Migma IV High Energy Fusion Apparatus

1977; Institute of Electrical and Electronics Engineers; Volume: 24; Issue: 3 Linguagem: Inglês

10.1109/tns.1977.4328830

ISSN

1558-1578

Autores

Juan Ferrer, R. Ho, M.G. Mazarakis, S. Mensian, J. Nering, C. Powell, Jorma Sandberg, James R. Treglio, Bogdan C. Maglich,

Tópico(s)

Fusion materials and technologies

Resumo

In order to study the scattering-dominated regime in a migma high energy fusion device, several improvements were made to the experimental apparatus. The injected beam current was increased; protective systems and cooled beam stops were installed to handle the beam power. The migma diagnostics include rf pickup electrodes for continuous monitoring of orbit distributions, silicon surface barrier detectors for observation of fusion products in coincidence and a charge-exchange neutral particle detector.

Referência(s)