Artigo Revisado por pares

The Performance of a Loop Seal in a CFB Boiler

2006; ASM International; Volume: 128; Issue: 2 Linguagem: Inglês

10.1115/1.2199567

ISSN

1528-8994

Autores

Andreas Johansson, Filip Johnsson, Bengt-Åke Andersson,

Tópico(s)

Metallurgical Processes and Thermodynamics

Resumo

High in-bed heat transfer and low corrosive environment imply that the loop seal of a circulating fluidized bed (CFB) boiler is an advantageous location for superheaters. In order to increase the knowledge on the flow pattern and the heat transfer distribution to the tubes within a loop seal, measurements were performed in the loop seal of a 30MW CFB boiler as well as in a 1∕3 scaled-down seal operated according to simplified scaling laws. The scale model measurements show that the solids recirculation flux can be maintained with a substantial decrease of the fluidization flow in the seal compared to that currently used at full load conditions. It was also possible to significantly decrease the fraction of the bottom of the seal that was fluidized without affecting the solids flux through the seal. A gradient in the solids flow were detected in the vertical direction.

Referência(s)