Artigo Revisado por pares

Zum Prinzip der automatischen Bestimmung von Amplitude, Leitungsgeschwindigkeit, Laufzeitlatenz und Refraktärperiode des Summenaktionspotentials peripherer Nerven. Ergebnisse am N. suralis des Menschen

1980; Georg Thieme Verlag; Volume: 11; Issue: 02 Linguagem: Inglês

10.1055/s-2008-1061134

ISSN

1439-4081

Autores

H. Muche, Philipp Schütt,

Tópico(s)

Musculoskeletal pain and rehabilitation

Resumo

A method for the automatical determination of the amplitude, the transmission time, the conduction velocity and the refractory period of sural nerve was evaluated by help of HISTO-MAT-S/MULTI 20 computer. The results of the automatical analysis were compared with those of the conventional method in 50 healthy control persons. There was no significant difference between the dates. Accuracy and correctness were exactly in the same range, but the investigation time of the analysis by help of a computer is much shorter.

Referência(s)
Altmetric
PlumX