DELAYED RUPTURE OF EXTENSOR DIGITORUM COMMUNIS TENDON FOLLOWING VOLAR PLATING OF DISTAL RADIUS FRACTURE
2008; World Scientific; Volume: 13; Issue: 03 Linguagem: Inglês
10.1142/s0218810408004055
ISSN1793-6535
AutoresYasunori Hattori, Kazuteru Doi, Soutetsu Sakamoto, Kiminori Yukata,
Tópico(s)Medical Malpractice and Liability Issues
ResumoWe present a case of delayed rupture of extensor digitorum communis tendon seven years after volar plating of distal radius fracture. Drill bit penetration during surgery and prominent screw tips into the fourth extensor compartment have a potential risk to damage the tendons. Careful and accurate use of internal fixation instruments is necessary to avoid this complication.
Referência(s)