Artigo Revisado por pares

Concentric‐needle single‐fiber electromyography for the diagnosis of myasthenia gravis

2006; Wiley; Volume: 34; Issue: 2 Linguagem: Inglês

10.1002/mus.20568

ISSN

1097-4598

Autores

Michael Benatar, Mustafa Hammad, Heidi Doss‐Riney,

Tópico(s)

Peripheral Neuropathies and Disorders

Resumo

Abstract The goal of this study was to estimate the accuracy of concentric‐needle single‐fiber electromyography (CN‐SFEMG) for the diagnosis of myasthenia gravis (MG). A consecutive series of patients referred for CN‐SFEMG was evaluated by an investigator blinded to the results of CN‐SFEMG in order to determine the presence or absence of MG using an independent reference standard. Sensitivity, specificity, predictive values, and likelihood ratios were calculated. The study population included 51 patients (21 with MG). CN‐SFEMG was normal in 34 patients (67%) and abnormal in 17 (33%). The sensitivity of CN‐SFEMG for the diagnosis of MG was 0.67 and the specificity was 0.96. The positive likelihood ratio was 16.8 and the negative likelihood ratio was 0.34. The positive and negative predictive values were 0.93 and 0.76, respectively. These results indicate that CN‐SFEMG showing abnormal jiggle is extremely useful for confirming the diagnosis of MG, but that CN‐SFEMG showing normal jiggle has limited utility in excluding the diagnosis. Muscle Nerve, 2006

Referência(s)
Altmetric
PlumX