Comparative assessment of HFC134a and some refrigerants as alternatives to CFC12
1992; Elsevier BV; Volume: 15; Issue: 2 Linguagem: Francês
10.1016/0140-7007(92)90035-s
ISSN1879-2081
Autores Tópico(s)Thermodynamic and Exergetic Analyses of Power and Cooling Systems
ResumoA composite plot relating evaporating temperature TEV, condensing temperature TCO, pressure ratio (PR) and theoretical Rankine coefficient of performance (COP)RR is presented for HFC134a. The theoretical performance of HFC134a has been comparatively assessed along with HCFC22, HFC134, HFC152a, HCFC124 and HCFC142b as alternatives to CFC12 by using the standard refrigeration parameters including pressure ratio, specific compressor displacement, theoretical Rankine coefficient of performance, shaft power per ton of refrigeration. A discussion of the practical implications of the choice of the alternatives to CFC12 is also presented. On présente, pour le R134a, un diagramme reliant la température d'évaporation TEV, la température de condensation TCO, le rapport de compression PR et le coefficient de performance du cycle théorique de Rankine (COP)RR. On a comparé la performance théorique du R134a avec celles du R22, du R134, du R152a, du R124 et du R142b, utilisés comme substituts au R12, en se référant aux caractéristiques frigorifiques habituelles dont le rapport de compression, le déplacement spécifique du compresseur, le coefficient de performance du cycle de Rankine théorique, la puissance de l'arbre par T de réfrigération (environ 3500 W). On présente également une discussion sur les implications practiques du choix des substitutes au R12.
Referência(s)