Artigo Acesso aberto Produção Nacional Revisado por pares

Alternativas quimiométricas para a resolução de problemas analíticos clássicos: determinação espectrofotométrica de misturas de zircônio e háfnio

1997; Brazilian Chemical Society; Volume: 20; Issue: 5 Linguagem: Inglês

10.1590/s0100-40421997000500005

ISSN

1678-7064

Autores

Patricio Peralta‐Zamora, Lorena Cornejo‐Ponce, Noemi Nagata, Ronei J. Poppi,

Tópico(s)

Water Quality Monitoring and Analysis

Resumo

PROB-LEMS.SPECTROPHOTOMETRIC DETERMINATION OF ZIRCONIUM-HAFNIUM MIXTURES.The determination of zirconium-hafnium mixtures is one of the most critical problem of the analytical chemistry, on account of the close similarity of their chemical properties.The spectrophotometric determination proposed by Yagodin et al. show not many practical applications due to the significant spectral interference on the 200-220 nm region.In this work we propound the use of a multivariate calibration method called partial least squares ( PLS ) for colorimetric determination of these mixtures.By using PLS and 16 calibration mixtures we obtained a model which permits determination of zirconium and hafnium with accuracy of about 1-2% and 10-20%, respectively.Using conventional univariate calibration the inaccuracy of the determination is about 10-25% for zirconium and above 57% for hafnium.

Referência(s)
Altmetric
PlumX