Apical Transportation: A Comparative Evaluation of Three Root Canal Instrumentation Techniques with Three Different Apical Diameters
2008; Elsevier BV; Volume: 34; Issue: 12 Linguagem: Inglês
10.1016/j.joen.2008.07.027
ISSN1878-3554
AutoresFernanda Ullmann López, Elaine Vianna Freitas Fachin, Vânia Regina Camargo Fontanella, Fernando Branco Barletta, Marcus Vinícius Reis Só, Fabiana Soares Grecca,
Tópico(s)Dental Anxiety and Anesthesia Techniques
ResumoThis study conducted an in vitro analysis of the level of apical transportation in mesiobuccal roots of upper molars after manual instrumentation with stainless steel files, preparation with the K3 system, and with a reciprocating NSK handpiece. Sixty roots were mounted in muffles and then longitudinally sectioned. A digital image was acquired of the inner surface of one root half. After instrumentation, the inner surfaces of the same root halves were digitized with file sizes #30, #35, and #40. Each image obtained was superimposed over the corresponding preoperative image, and the apical transportation was measured. The Friedman and Wilcoxon tests were used to compare results for the file sizes, and comparison of the groups was made with the Kruskal-Wallis test, demonstrating statistically significant differences (P = .000). The stainless steel file sizes #35 and #40 caused significant apical transportation, and K3 system proved safe for apical preparation, with little deviation.
Referência(s)