Comparison of the Sirolimus-Eluting Versus Paclitaxel-Eluting Coronary Stent in Patients With Diabetes Mellitus: The Diabetes and Drug-Eluting Stent (DiabeDES) Randomized Angiography Trial††A list of participating centers and investigators appears in the Appendix.
2008; Elsevier BV; Volume: 103; Issue: 3 Linguagem: Inglês
10.1016/j.amjcard.2008.09.084
ISSN1879-1913
AutoresMichael Mæng, Lisette Okkels Jensen, Anders Galløe, Per Thayssen, Evald Høj Christiansen, Knud Nørregaard Hansen, Steffen Helqvist, Hans Erik Bøtker, Jens Flensted Lassen, Leif Thuesen,
Tópico(s)Antiplatelet Therapy and Cardiovascular Diseases
ResumoThe aim of the present study was to evaluate angiographic late luminal loss after the implantation of sirolimus-eluting Cypher stents and paclitaxel-eluting Taxus stents in patients with diabetes. The study was a Danish multicenter, open-label, randomized trial. One hundred fifty-three patients with diabetes with coronary artery disease were randomized to Cypher (n = 76) or Taxus (n = 77) stent implantation. All patients were followed for 8 months. The primary end point was 8-month angiographic in-stent late luminal loss. This primary end point was reduced in the Cypher group compared with the Taxus group (0.23 ± 0.54 vs 0.44 ± 0.52 mm, p = 0.025). Angiographic in-segment restenosis at 8-month follow-up, a secondary end point, was present in 16 patients (Cypher, n = 6; Taxus, n = 10; p = 0.24). Target lesion revascularization was performed in 5 patients (6.5%) and 9 patients (11.8%) in the Cypher and Taxus groups, respectively (p = 0.25). Definite stent thrombosis was observed in 2 patients (in the Taxus group), no patients had probable stent thrombosis, and 1 patient in each group had possible stent thrombosis. Major adverse cardiac events (cardiac death, myocardial infarction, definite stent thrombosis, or target lesion revascularization) were observed in 17 patients (Cypher, n = 6; Taxus, n = 11; p = 0.19). In conclusion, angiographic in-stent late luminal loss is significantly reduced in patients with diabetes by use of the sirolimus-eluting Cypher stent compared with the paclitaxel-eluting Taxus stent. The aim of the present study was to evaluate angiographic late luminal loss after the implantation of sirolimus-eluting Cypher stents and paclitaxel-eluting Taxus stents in patients with diabetes. The study was a Danish multicenter, open-label, randomized trial. One hundred fifty-three patients with diabetes with coronary artery disease were randomized to Cypher (n = 76) or Taxus (n = 77) stent implantation. All patients were followed for 8 months. The primary end point was 8-month angiographic in-stent late luminal loss. This primary end point was reduced in the Cypher group compared with the Taxus group (0.23 ± 0.54 vs 0.44 ± 0.52 mm, p = 0.025). Angiographic in-segment restenosis at 8-month follow-up, a secondary end point, was present in 16 patients (Cypher, n = 6; Taxus, n = 10; p = 0.24). Target lesion revascularization was performed in 5 patients (6.5%) and 9 patients (11.8%) in the Cypher and Taxus groups, respectively (p = 0.25). Definite stent thrombosis was observed in 2 patients (in the Taxus group), no patients had probable stent thrombosis, and 1 patient in each group had possible stent thrombosis. Major adverse cardiac events (cardiac death, myocardial infarction, definite stent thrombosis, or target lesion revascularization) were observed in 17 patients (Cypher, n = 6; Taxus, n = 11; p = 0.19). In conclusion, angiographic in-stent late luminal loss is significantly reduced in patients with diabetes by use of the sirolimus-eluting Cypher stent compared with the paclitaxel-eluting Taxus stent.
Referência(s)