Fat-suppression magnetic resonance imaging in the preoperative localization of parathyroid adenomas
1992; Elsevier BV; Volume: 46; Issue: 5 Linguagem: Inglês
10.1016/s0009-9260(05)80376-9
ISSN1365-229X
AutoresA Wright, P R Goddard, S Nicholson, D. Kinsella, E. Rhys Davies, J R Farndon,
Tópico(s)MRI in cancer diagnosis
ResumoProspective localization of parathyroid adenomas was attempted in 16 patients with hyperparathyroidism prior to surgery. All patients had magnetic resonance imaging (MRI) using T1-weighted spin-echo (SE) sequences and a fat-suppression sequence, the short-tau inversion recovery (STIR) sequence. Correlation with the results of surgery yielded an overall sensitivity of 71% and a specificity of 94%. Performance was good in patients with previous surgery and with ectopic tumours. We believe that fat-suppression MRI is a valuable technique in the preoperative localization of parathyroid adenomas in patients with hyperparathyroidism.