Artigo Acesso aberto Revisado por pares

Assessing the Stability and Safety of Procedure during Endoscopic Submucosal Dissection According to Sedation Methods: A Randomized Trial

2015; Public Library of Science; Volume: 10; Issue: 3 Linguagem: Inglês

10.1371/journal.pone.0120529

ISSN

1932-6203

Autores

Chan Hyuk Park, Seokyung Shin, Sang Kil Lee, Hyuk Lee, Yong Chan Lee, Jun Chul Park, Young Chul Yoo,

Tópico(s)

Gastroesophageal reflux and treatments

Resumo

Background Although endoscopic submucosal dissection (ESD) is routinely performed under sedation, the difference in ESD performance according to sedation method is not well known. This study attempted to prospectively assess and compare the satisfaction of the endoscopists and patient stability during ESD between two sedation methods. Methods One hundred and fifty-four adult patients scheduled for ESD were sedated by either the IMIE (intermittent midazolam/propofol injection by endoscopist) or CPIA (continuous propofol infusion by anesthesiologist) method. The primary endpoint of this study was to compare the level of satisfaction of the endoscopists between the two groups. The secondary endpoints included level of satisfaction of the patients, patient's pain scores, events interfering with the procedure, incidence of unintended deep sedation, hemodynamic and respiratory events, and ESD outcomes and complications. Results Level of satisfaction of the endoscopists was significantly higher in the CPIA Group compared to the IMIE group (IMIE vs. CPIA; high satisfaction score; 63.2% vs. 87.2%, P=0.001). The incidence of unintended deep sedation was significantly higher in the IMIE Group compared to the CPIA Group (IMIE vs. CPIA; 17.1% vs. 5.1%, P=0.018) as well as the number of patients showing spontaneous movement or those requiring physical restraint (IMIE vs. CPIA; spontaneous movement; 60.5% vs. 42.3%, P=0.024, physical restraint; 27.6% vs. 10.3%, P=0.006, respectively). In contrast, level of satisfaction of the patients were found to be significantly higher in the IMIE Group (IMIE vs. CPIA; high satisfaction score; 85.5% vs. 67.9%, P=0.027). Pain scores of the patients, hemodynamic and respiratory events, and ESD outcomes and complications were not different between the two groups. Conclusion Continuous propofol and remifentanil infusion by an anesthesiologist during ESD can increase the satisfaction levels of the endoscopists by providing a more stable state of sedation. Trial Registration ClinicalTrials.gov NCT01806753

Referência(s)