DETRUSOR PRESSURE UROFLOWMETRY STUDIES IN WOMEN: EFFECT OF A 7FR TRANSURETHRAL CATHETER
2000; Lippincott Williams & Wilkins; Volume: 164; Issue: 1 Linguagem: Inglês
10.1016/s0022-5347(05)67460-5
ISSN1527-3792
AutoresAsnat Groutz, Jerry G. Blaivas, A. MARGHERITA SASSONE,
Tópico(s)Urinary Tract Infections Management
ResumoNo AccessJournal of UrologyCLINICAL UROLOGY: Female Urology1 Jul 2000DETRUSOR PRESSURE UROFLOWMETRY STUDIES IN WOMEN: EFFECT OF A 7FR TRANSURETHRAL CATHETER ASNAT GROUTZ, JERRY G. BLAIVAS, and A. MARGHERITA SASSONE ASNAT GROUTZASNAT GROUTZ , JERRY G. BLAIVASJERRY G. BLAIVAS , and A. MARGHERITA SASSONEA. MARGHERITA SASSONE View All Author Informationhttps://doi.org/10.1016/S0022-5347(05)67460-5AboutFull TextPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract Purpose: We evaluated whether a 7Fr transurethral catheter affects urinary flow in women undergoing pressure flow studies for voiding symptoms. Materials and Methods: We reviewed a urodynamic database of 600 consecutive women referred for the evaluation of voiding symptoms. Before urodynamics all patients voided privately using a standard toilet and free flow was recorded. Urodynamics were performed using a 7Fr double lumen transurethral catheter. At functional bladder capacity patients were asked to void in the sitting position and pressure flow studies were performed. All uroflowmetry tracings were inspected and analyzed manually. Only patients who voided similar volumes varying by less than 20% on the free and pressure flow studies were assessed. Free and pressure flow parameters were compared according to voided volume category, main urodynamic diagnosis, uroflowmetry pattern and pre-void bladder volume. Results: A similar volume was voided on the free and pressure flow studies of 100 women. In each voided volume category and urodynamic diagnosis pressure flow parameters were significantly different from the equivalent free flow parameters in all but 4 cases. Specifically the maximum flow rate was significantly less and flow time was significantly longer on pressure versus free flow studies (each p <0.01). An intermittent flow pattern was more common on pressure than in free flow measurements (43% versus 9%). Conclusions: A 7Fr transurethral catheter may adversely affect uroflowmetry parameters in women undergoing pressure flow studies for lower urinary tract symptoms. This finding may have further clinical implications regarding the interpretation of these parameters as well as establishment of an accurate diagnosis. References 1 : Standardization of terminology of lower urinary tract function: pressure-flow studies of voiding, urethral resistance, and urethral obstruction. Neurourol Urodyn1997; 16: 1. Crossref, Medline, Google Scholar 2 : The effect of a urethral catheter on the measurement of maximum urinary flow rate. J Urol1982; 128: 429. Link, Google Scholar 3 : Spontaneous versus intubated flow in male patients. Urology1988; 32: 553. Google Scholar 4 : Impact of different sized catheters on pressure-flow studies in patients with benign prostatic hyperplasia. Neurourol Urodyn1996; 15: 473. Google Scholar 5 : Pressure-flow studies in the diagnosis of bladder outlet obstruction: a study comparing suprapubic and transurethral techniques. Br J Urol1997; 79: 693. Google Scholar 6 : Precise urodynamic assessment of anatomic urethral obstruction in boys. Neurourol Urodyn1982; 1: 97. Google Scholar 7 : Effect of varying size of urethral catheters upon flow and resistance measurements. Neurourol Urodyn1986; 5: 277. Google Scholar 8 : Effects of catheter size on urodynamic measurements in men undergoing elective prostatectomy. Br J Urol1987; 60: 64. Google Scholar 9 : The obstructive effect of a urethral catheter. J Urol1996; 155: 901. Link, Google Scholar 10 : Precise urodynamic assessment of meatal and distal urethral stenosis in girls. Neurourol Urodyn1982; 1: 89. Google Scholar 11 : The effect of a fine urethral pressure-measuring catheter on urinary flow in females. Neurourol Urodyn1984; 3: 163. Google Scholar 12 : A comparison of spontaneous and intubated urinary flow in female patients. Neurourol Urodyn1986; 5: 1. Google Scholar 13 : The influence of a urethral catheter and age on recorded urinary flow rates in healthy women. Scand J Urol Nephrol1989; 23: 261. Google Scholar 14 : Effect of size 7FG urethral catheter on urine flow rates in urogynaecology patients. Int Urogynecol J1999; 10: S98. abstract. Google Scholar 15 : Standardisation of terminology of lower urinary tract function. International Continence Society Committee on Standardization of Terminology. Neurourol Urodyn1988; 7: 403. Google Scholar 16 : Male peak urinary flow rate: relationships to volume voided and age. J Urol1979; 122: 210. Link, Google Scholar 17 : . London: Chapman and Hall1991: 241. Google Scholar 18 : The contribution of the bladder outlet to the relation between pressure and flow rate during micturition. In: . New York: Springer-Verlag1983: 470. Google Scholar From the Weill Medical College, Cornell University, New York, New York© 2000 by American Urological Association, Inc.FiguresReferencesRelatedDetailsCited byWein A (2010) Voiding Function and Dysfunction, Bladder Physiology and Pharmacology, and Female UrologyJournal of Urology, VOL. 184, NO. 4, (1419-1423), Online publication date: 1-Oct-2010.Akikwala T, Fleischman N and Nitti V (2018) Comparison of Diagnostic Criteria for Female Bladder Outlet ObstructionJournal of Urology, VOL. 176, NO. 5, (2093-2097), Online publication date: 1-Nov-2006.Kessler T, Studer U and Burkhard F (2018) The Effect of Terazosin on Functional Bladder Outlet Obstruction in Women: A Pilot StudyJournal of Urology, VOL. 176, NO. 4, (1487-1492), Online publication date: 1-Oct-2006.WAGNER A, GODLEY M, DUFFY P and RANSLEY P (2018) A Novel, Inexpensive, Double Lumen Suprapubic Catheter for UrodynamicsJournal of Urology, VOL. 171, NO. 3, (1277-1279), Online publication date: 1-Mar-2004.BRADLEY C and ROVNER E (2018) Urodynamically Defined Stress Urinary Incontinence and Bladder Outlet Obstruction Coexist in WomenJournal of Urology, VOL. 171, NO. 2, (757-761), Online publication date: 1-Feb-2004.CORMIER L, FERCHAUD J, GALAS J, GUILLEMIN F and MANGIN P (2018) Diagnosis of Female Bladder Outlet Obstruction and Relevance of the Parameter Area Under the Curve of Detrusor Pressure During Voiding: Preliminary ResultsJournal of Urology, VOL. 167, NO. 5, (2083-2087), Online publication date: 1-May-2002.MANIAM P and GOLDMAN H (2018) Removal of Transurethral Catheter During Urodynamics May Unmask Stress Urinary IncontinenceJournal of Urology, VOL. 167, NO. 5, (2080-2082), Online publication date: 1-May-2002. Volume 164Issue 1July 2000Page: 109-114 Advertisement Copyright & Permissions© 2000 by American Urological Association, Inc.KeywordsbladderurodynamicsurethracatheterizationflowmetryMetricsAuthor Information ASNAT GROUTZ More articles by this author JERRY G. BLAIVAS More articles by this author A. MARGHERITA SASSONE More articles by this author Expand All Advertisement PDF downloadLoading ...
Referência(s)