Resumo

The use of transoesophageal echocardiography during cardiac surgery has increased dramatically and it is now widely accepted as a routine monitoring and diagnostic tool. A prospective study was carried out between September 2004 and September 2007, and included all patients in whom intra-operative echocardiography was performed, 2 473 (44%) out of a total of 5 591 cases. Changes to surgery were subdivided into predictable (where echocardiographic examination was planned specifically to guide surgery) and unpredictable (new pathology not diagnosed pre-operatively). A change in the planned surgical procedure was documented in 312 (15%) cases. In 216 (69%) patients the changes were predictable and in 96 (31%) they were unpredictable. The number of predictable changes increased between 2004-5 and 2006-7 (8% vs 13%, p = 0.025). In these cases, intra-operative echocardiography was specifically requested by the surgeon to help determine the operative intervention. This has implications for consent and operative risk, which have yet to be fully determined.