Artigo Revisado por pares

A comparative physical study of two different hydrophilic synthetic latex matrices for the construction of a glucose biosensor

2001; Elsevier BV; Volume: 55; Issue: 5 Linguagem: Inglês

10.1016/s0039-9140(01)00498-2

ISSN

1873-3573

Autores

Serge Cosnier, Sabine Szunerits, Robert S. Marks, Andrés Novoa, Laurence Puech, Émile Perez, Isabelle Rico‐Lattes,

Tópico(s)

Electrochemical Analysis and Applications

Resumo

Two different biodegradable latex polymers functionalised by hydroxy (1) or gluconamide (2) groups proved to be good immobilisation matrixes for glucose oxidase. The responses of these biosensors to glucose additions were measured by potentiostating the modified electrodes at 0.6 V/SCE in order to oxidise the hydrogen peroxide generated by the enzymatic oxidation of glucose in the presence of oxygen. The response of such electrodes was evaluated as a function of film thickness, pH and temperature. Rotating disk electrode experiments showed the influence of the enzyme on the structure of both latex films, namely a marked improvement in matrix permeability. The high permeability of the latex 1 based enzyme sensor (bilayer, P(m)=8.10x10(-4) cm s(-1)) resulted in a high dynamic range. Furthermore, the activation energy for a latex 1 sensor was determined to be 44.55 and 18.03 kJ mol(-1), respectively depending on the conformation of the enzyme.

Referência(s)
Altmetric
PlumX