Artigo Revisado por pares

Characterization of impurity confinement on Alcator C-Mod using a multi-pulse laser blow-off system

2011; American Institute of Physics; Volume: 82; Issue: 3 Linguagem: Inglês

10.1063/1.3565448

ISSN

1527-2400

Autores

N. T. Howard, M. Greenwald, J. E. Rice,

Tópico(s)

Fusion materials and technologies

Resumo

A new laser blow-off system for use in impurity transport studies on Alcator C-Mod was developed and installed for the 2009 run campaign. Its design included capabilities for multiple impurity injections during a single plasma pulse and remote manipulation of the ablated spot size. The system uses a 0.68 J, Nd:YAG laser operating at up to 10 Hz coupled with the fast beam steering via a 2D piezoelectric mirror mount able to move spot locations in the 100 ms between laser pulses and a remote controllable optical train that allow ablated spot sizes to vary from ∼0.5 to 7 mm. The ability to ablate a wide range in target Z along with Alcator C-Mod's extensive diagnostic capabilities (soft x-ray, vacuum ultraviolet (VUV), charge exchange spectroscopy, etc.) allows for detailed studies of the impurity transport dependencies and mechanisms. This system has demonstrated the achievement of all its design goals including the ability for non-perturbative operation allowing for insight into underlying impurity transport processes. A detailed overview of the laser blow-off system and initial results of operation are presented. This includes an investigation into the characterization of impurity confinement in the I-mode confinement regime recently investigated on C-Mod.

Referência(s)