Artigo Acesso aberto Revisado por pares

Clinical cross-over comparison of mid-dilution hemodiafiltration using a novel dialyzer concept and post-dilution hemodiafiltration

2004; Elsevier BV; Volume: 67; Issue: 1 Linguagem: Inglês

10.1111/j.1523-1755.2005.00088.x

ISSN

1523-1755

Autores

Detlef H. Krieter, Sven Falkenhain, Lotfi Chalabi, Gregory Collins, Horst‐Dieter Lemke, Bernard Canaud,

Tópico(s)

Acute Kidney Injury Research

Resumo

Clinical cross-over comparison of mid-dilution hemodiafiltration using a novel dialyzer concept and post-dilution hemodiafiltration.BackgroundSeveral studies have indicated that the improved elimination of middle molecules by convective renal replacement procedures might be associated with a better outcome in end-stage renal disease (ESRD). On-line mid-dilution hemodiafiltration (HDF) with the Nephros OLpūr™ MD 190 hemodiafilter represents a novel extracorporeal renal replacement therapy concept to increase the removal of middle molecules.MethodsIn a prospective cross-over study in 10 ESRD patients, this technique was compared to on-line post-dilution HDF with a conventional synthetic high-flux dialyzer, operated at its technical limit, concerning small and middle molecular solute removal. Each patient was treated 3 times for 4.0 ± 0.4 hours with both filters. Blood flow was 400 mL/min, substitution flow (QS) during mid-dilution HDF 200 mL/min, and during post-dilution HDF 100 mL/min, and effective dialysate flow of 700 – QS mL/min. Instantaneous clearances, reduction ratios (RR), and middle molecule mass transfer in continuously collected dialysate were determined.ResultsWhile urea and creatinine clearances were significantly lower (6.4% and 3.9%, respectively), middle molecule removal was much more efficient in mid-dilution HDF over the whole range of investigated proteins: compared to post-dilution HDF, β2-microglobulin (11.8 kD) clearance (165.8 ± 26.59 vs. 201.9 ± 20.63 mL/min; P < 0.001), RR (80.0 ± 5.4% vs. 82.2 ± 5.7%; P < 0.001), and dialysate mass transfer (53% higher; P < 0.001) were significantly higher. For the larger middle molecules, cystatin C (13.4 kD) and retinol-binding protein (21.2 kD), mid-dilution HDF resulted in an even more superior performance, indicated by significantly higher values of all investigated parameters.ConclusionOn-line mid-dilution HDF with the Nephros OLpūr™ MD 190 hemodiafilter appears to be a true technologic step ahead in terms of improved middle molecule removal. This efficient procedure gives hope to play a role in preventing or at least retarding dialysis-related long-term complications, such as β2m amyloidosis, in ESRD patients, and may contribute to a more adequate dialysis therapy. Clinical cross-over comparison of mid-dilution hemodiafiltration using a novel dialyzer concept and post-dilution hemodiafiltration. Several studies have indicated that the improved elimination of middle molecules by convective renal replacement procedures might be associated with a better outcome in end-stage renal disease (ESRD). On-line mid-dilution hemodiafiltration (HDF) with the Nephros OLpūr™ MD 190 hemodiafilter represents a novel extracorporeal renal replacement therapy concept to increase the removal of middle molecules. In a prospective cross-over study in 10 ESRD patients, this technique was compared to on-line post-dilution HDF with a conventional synthetic high-flux dialyzer, operated at its technical limit, concerning small and middle molecular solute removal. Each patient was treated 3 times for 4.0 ± 0.4 hours with both filters. Blood flow was 400 mL/min, substitution flow (QS) during mid-dilution HDF 200 mL/min, and during post-dilution HDF 100 mL/min, and effective dialysate flow of 700 – QS mL/min. Instantaneous clearances, reduction ratios (RR), and middle molecule mass transfer in continuously collected dialysate were determined. While urea and creatinine clearances were significantly lower (6.4% and 3.9%, respectively), middle molecule removal was much more efficient in mid-dilution HDF over the whole range of investigated proteins: compared to post-dilution HDF, β2-microglobulin (11.8 kD) clearance (165.8 ± 26.59 vs. 201.9 ± 20.63 mL/min; P < 0.001), RR (80.0 ± 5.4% vs. 82.2 ± 5.7%; P < 0.001), and dialysate mass transfer (53% higher; P < 0.001) were significantly higher. For the larger middle molecules, cystatin C (13.4 kD) and retinol-binding protein (21.2 kD), mid-dilution HDF resulted in an even more superior performance, indicated by significantly higher values of all investigated parameters. On-line mid-dilution HDF with the Nephros OLpūr™ MD 190 hemodiafilter appears to be a true technologic step ahead in terms of improved middle molecule removal. This efficient procedure gives hope to play a role in preventing or at least retarding dialysis-related long-term complications, such as β2m amyloidosis, in ESRD patients, and may contribute to a more adequate dialysis therapy.

Referência(s)
Altmetric
PlumX