On-Chip High-Pressure Picoliter Injector for Pressure-Driven Flow through Porous Media
2004; American Chemical Society; Volume: 76; Issue: 17 Linguagem: Inglês
10.1021/ac0493572
ISSN1520-6882
AutoresDavid. Reichmuth, Timothy J. Shepodd, Brian J. Kirby,
Tópico(s)Electrohydrodynamics and Fluid Dynamics
ResumoA high-pressure (>3 MPa) on-chip injector has been developed for microchip applications including HPLC. The mechanical injector is implemented using in situ photopolymerization of fluorinated acrylates inside wet-etched silica microchips. The injector allows reproducible injections as small as 180 pL with <250 ms duration. The injector operated robustly over 60 days and over 1000 injections. The injector is unique among polymer-based valves as it functions in aqueous, acetonitrile, and mixed buffers at high pressures without detectable leakage.
Referência(s)