Construction and performance of the L3 central tracking detector
1993; Elsevier BV; Volume: 332; Issue: 1-2 Linguagem: Inglês
10.1016/0168-9002(93)90740-9
ISSN1872-9576
AutoresF. Beißel, A. Böhm, K. Bosseler, C. Camps, V. Commichau, M. Deutschmann, Heiko Frohn, David N. Jansen, P. Göttlicher, J. Grooten, K. Hangarter, G. Herten, H. Liebmann, J. Mnich, M. Möller, R. Pahlke, W. Reuter, N. Rieb, U. Rinsche, S. Röhner, J. Rose, K. Quadflieg, P. Schmitz, R. Schulte, S. Schulte, K. Schultze, T. Spickermann, R. Starosta, H. Szczesny, M. Sassowsky, M. Tonutti, H. Virnich, T. Winands, J.C. Sens, D. Bourilkov, D.J. Schotanus, H. Akbari, J. Bao, Chih‐Yen Chien, P.H. Fisher, A. Gougas, D. Newman, Joseph Orndorff, A. Pevsner, J. Spangler, C. Spartiotis, G. Alverson, M. Glaubman, I. Leedom, S. Reucroft, L. Taylor, G. Barbier, P. Béné, M. Bourquin, J.H. Field, G. Forconi, D. La Marra, A. Léger, F. Masciocchi, J. Perrier, E. Perrin, N. Produit, J.P. Richeux, M. Weber, Liudmil Antonov, Stefan Botev, V.R. Krastev, I. Orlinov, A. Hasan, G. Sultanov, P. Vikas, E. Haerdi, K. Deiters, A. Donat, W. Friebel, René Heller, Stefan Kirsch, Rainer Krankenhagen, W. Lange, R. Leiste, W. Lohmann, W. Lustermann, U. Röser, Y. Peng, F. Tonisch, G. Trowitzsch, H. Vogt, M. Wilhelmi, H. Anderhub, W. Baur, F. Beauvais, F. Behner, J. Behrens, B.L. Betev, A. Biland, L. Djambazov, M. Dhina, J. Fehlmann, Moritz Hänsli, J. Herrmann, H. Höfer, U. Horisberger, E. Isiksal, H. Jung, W. Kästli, K. Lanius, X. Lue, C. Neyer, M. Maolinbay, D. McNally, M. Okle, M. Pohl, G. Rahal-Callot, D. Ren, H. Schuijlenburg, B. Stöhr, H. Suter, H. Thürig, J. Ulbricht, G.M. Viertel, H.P. von Gunten, S. Waldmeier, J. Weber, L. Zehnder, P. Zemp,
Tópico(s)Medical Imaging Techniques and Applications
ResumoThe L3 central tracking detector has been in operation since the start-up of LEP (Large Electron Positron collider) in 1989. This detector consists of a Time Expansion Chamber (TEC), a layer of Plastic Scintillating Fibers and a Z-chamber. The TEC gives a high spatial resolution and an excellent multi-track reconstruction capability. The fibers are designed to calibrate the drift velocity with high precision. The Z-Chamber provides TEC with accurate information about the z-coordinates of the tracks. A description of the design and the infrastructure of these three detectors, including the readout and data acquisition system, is given. The performance of the detectors during the 1990 and 1991 LEP running periods is presented.
Referência(s)