Artigo Acesso aberto Revisado por pares

Developmental validation of a fully integrated sample-to-profile rapid human identification system for processing single-source reference buccal samples

2015; Elsevier BV; Volume: 16; Linguagem: Inglês

10.1016/j.fsigen.2014.12.004

ISSN

1878-0326

Autores

Stevan Jovanovich, Greg Bogdan, Richard Belcinski, Jacklyn Buscaino, Dean S. Burgi, Erica L.R. Butts, Kaiwan Chear, Brian Ciopyk, David Eberhart, Omar El-Sissi, Helen Franklin, Stefanie Gangano, Jennifer Gass, Dennis W. Harris, Lori K. Hennessy, Alex Kindwall, David G. King, Jim Klevenberg, Yuan Li, Neelima Mehendale, Roger C. McIntosh, Bill Nielsen, Charles Park, Francesca Pearson, Robert Schueren, Nancy Stainton, Charles Troup, Peter M. Vallone, Mattias Vangbo, Timothy M. Woudenberg, David L. Wyrick, Stephen J. Williams,

Tópico(s)

Biosensors and Analytical Detection

Resumo

Short tandem repeat (STR) DNA typing is a global standard for human identification. Current practice involves highly trained forensic analysts, operating in a laboratory setting, using multiple instruments to process samples and analyze the data. Here, we report the developmental validation of a fully integrated and automated DNA profiling system, the RapidHIT® System, capable of producing up to five high quality STR profiles with full controls in approximately 90min using PowerPlex®16 HS RapidHIT chemistry. The system integrates all sample handling steps: starting from lysis of cells on buccal swabs or other buccal sample types through DNA extraction, normalization, amplification,capillary array electrophoresis, detection, and integrated software analysis. The results describe the developmental validation of the RapidHIT™ System for buccal samples processed with the DNA IQ™ extraction chemistry using a guandinium chaotropic agent and paramagnetic beads followed by amplification using a modified version of PowerPlex 16 HS chemistry (PowerPlex 16 HS RapidHIT chemistry), and capillary electrophoresis with manual review of genotyping data following interpretation guidelines. All processing from the buccal swab to generation and processing of the profile occurs on the RapidHIT platform.are concordant with traditional methods, with 88% first pass success rates for both the CODIS and PowerPlex 16 loci. Average peak height ratios were 0.89 for buccal swabs. The system produces full profiles from swabs with at least 176 ng of saliva DNA. Rapid DNA identification systems will significantly enhance capabilities for forensic labs, intelligence, defense, law enforcement, refugee and immigration applications, and kinship analysis.

Referência(s)