Enhanced Viscoelasticity of Human Cystic Fibrotic Sputum Correlates with Increasing Microheterogeneity in Particle Transport
2003; Elsevier BV; Volume: 278; Issue: 50 Linguagem: Inglês
10.1074/jbc.m309026200
ISSN1083-351X
AutoresMichelle Dawson, Denis Wirtz, Justin Hanes,
Tópico(s)Inhalation and Respiratory Drug Delivery
ResumoCurrent biochemical characterizations of cystic fibrosis (CF) sputum do not address the high degree of microheterogeneity in the rheological properties of the mucosal matrix and only provide bulk-average particle diffusion coefficients. The viscoelasticity of CF sputum greatly reduces the diffusion rates of colloidal particles, limiting the effectiveness of gene delivery to underlying lung cells. We determine diffusion coefficients of hundreds of individual amine-modified and carboxylated polystyrene particles (diameter 100–500 nm) embedded in human CF sputum with 5 nm and 33 ms of spatiotemporal resolution. High resolution multiple particle tracking is used to calculate the effective viscoelastic properties of CF sputum at the micron scale, which we relate to its macroscopic viscoelasticity. CF sputum microviscosity, as probed by 100- and 200-nm particles, is an order of magnitude lower than its macroviscosity, suggesting that nanoparticles dispersed in CF sputum are transported primarily through lower viscosity pores within a highly elastic matrix. Multiple particle tracking provides a non-destructive, highly sensitive method to quantify the high heterogeneity of the mucus pore network. The mean diffusion coefficient becomes dominated by relatively few but fast-moving particles as particle size is reduced from 500 to 100 nm. Neutrally charged particles with a diameter <200 nm undergo more rapid transport in CF sputum than charged particles. Treatment with recombinant human DNase (Pulmozyme®) reduces macroviscoelastic properties of CF sputum by up to 50% and dramatically narrows the distribution of individual particle diffusion rates but surprisingly does not significantly alter the ensemble-average particle diffusion rate. Current biochemical characterizations of cystic fibrosis (CF) sputum do not address the high degree of microheterogeneity in the rheological properties of the mucosal matrix and only provide bulk-average particle diffusion coefficients. The viscoelasticity of CF sputum greatly reduces the diffusion rates of colloidal particles, limiting the effectiveness of gene delivery to underlying lung cells. We determine diffusion coefficients of hundreds of individual amine-modified and carboxylated polystyrene particles (diameter 100–500 nm) embedded in human CF sputum with 5 nm and 33 ms of spatiotemporal resolution. High resolution multiple particle tracking is used to calculate the effective viscoelastic properties of CF sputum at the micron scale, which we relate to its macroscopic viscoelasticity. CF sputum microviscosity, as probed by 100- and 200-nm particles, is an order of magnitude lower than its macroviscosity, suggesting that nanoparticles dispersed in CF sputum are transported primarily through lower viscosity pores within a highly elastic matrix. Multiple particle tracking provides a non-destructive, highly sensitive method to quantify the high heterogeneity of the mucus pore network. The mean diffusion coefficient becomes dominated by relatively few but fast-moving particles as particle size is reduced from 500 to 100 nm. Neutrally charged particles with a diameter <200 nm undergo more rapid transport in CF sputum than charged particles. Treatment with recombinant human DNase (Pulmozyme®) reduces macroviscoelastic properties of CF sputum by up to 50% and dramatically narrows the distribution of individual particle diffusion rates but surprisingly does not significantly alter the ensemble-average particle diffusion rate. Transport of viral particles, bacteria, and gene delivery vehicles to the lung epithelial cells is greatly limited by the respiratory sputum that sits on the apical surface of the cells (1.Hanes J. Dawson M. Har-el Y. Suh J. Fiegel J. Hickey A.J. Pharmaceutical Inhalation Aerosol Technology. 2nd Ed. Marcel Dekker Inc., New York2003: 489-539Google Scholar). Sputum forms a complex biological barrier composed of highly branched and strongly negatively charged mucus glycoproteins (∼10–40 MDa), water, lipids, salts, macromolecules, and cellular debris, which form a dense, highly viscoelastic protective barrier over epithelial cells in the conductive airways (2.Sanders N. De Smedt S. Demeester J. J. Pharm. Sci. 1999; 89: 835-849Abstract Full Text Full Text PDF Scopus (55) Google Scholar). The viscoelasticity of the mucosal layer is believed to be largely due to a high number of physical entanglements between mucus glycoproteins and the other mucosal constituents. These entanglements are stabilized by covalent and non-covalent interactions, including hydrogen bonding and electrostatic and hydrophobic interactions (3.Norris D.A. Puri N. Sinko P.J. J. Appl. Polym. Sci. 1997; 63: 1481-1492Crossref Scopus (155) Google Scholar, 4.Khanvilkar K. Donovan M.D. Flanagan D.R. Adv. Drug Deliv. Rev. 2001; 48: 173-193Crossref PubMed Scopus (269) Google Scholar). In the cystic fibrosis (CF) 1The abbreviations used are: CFcystic fibrosisMPTmultiple particle trackingMSDmean squared displacementrhDNaserecombinant human deoxyribonucleaseradradians. diseased state, the water content of sputum is reduced and the amount of cellular debris is increased, leading to an increase in the concentration of physical entanglements (cross-linking) and a pronounced increase in the viscoelastic nature of sputum (5.Sanders N.N. De Smedt S.C. Van Rompaey E. Simoens P. De Baets F. Demeester J. Am. J. Respir. Crit. Care Med. 2000; 162: 1905-1911Crossref PubMed Scopus (200) Google Scholar). cystic fibrosis multiple particle tracking mean squared displacement recombinant human deoxyribonuclease radians. The permeability of normal mucus is inversely related to its viscoelasticity (6.Bhat P.G. Flanagan D.R. Donovan M.D. J. Pharm. Sci. 1996; 85: 624-630Abstract Full Text PDF PubMed Scopus (76) Google Scholar). However, increasing viscoelasticity of CF sputum correlates with an increase in overall transport rates of 100–200-nm particles (5.Sanders N.N. De Smedt S.C. Van Rompaey E. Simoens P. De Baets F. Demeester J. Am. J. Respir. Crit. Care Med. 2000; 162: 1905-1911Crossref PubMed Scopus (200) Google Scholar). Current methods, such as fluorescent recovery after photobleaching and fluorescent imaging, used to determine the rate of diffusion of particles in CF sputum provide only the ensemble-averaged transport of particles through a non-physiologically thick sputum slab (5.Sanders N.N. De Smedt S.C. Van Rompaey E. Simoens P. De Baets F. Demeester J. Am. J. Respir. Crit. Care Med. 2000; 162: 1905-1911Crossref PubMed Scopus (200) Google Scholar, 7.Sanders N.N. Van Rompaey E. De Smedt S.C. Demeester J. Pharm. Res. 2002; 19: 451-456Crossref PubMed Scopus (31) Google Scholar, 8.Olmsted S.S. Padgett J.L. Yudin A.I. Whaley K.J. Moench T.R. Cone R.A. Biophys. J. 2001; 81: 1930-1937Abstract Full Text Full Text PDF PubMed Scopus (426) Google Scholar). Fluorescent recovery after photobleaching and fluorescent imaging do not provide individual particle transport rates and do not allow measurement of local heterogeneities in transport rates, which limits insight into complex transport phenomena that control particle diffusion in CF sputum. To elucidate the mode and rate of transport of individual particles in CF sputum, fluorescent polystyrene nanoparticles of controlled size and surface charge were embedded in CF sputum obtained from human volunteers. Particle size was varied from 100 to 500 nm, which is the relevant size range for adenovirus, liposomal, and polymer-mediated transfection (5.Sanders N.N. De Smedt S.C. Van Rompaey E. Simoens P. De Baets F. Demeester J. Am. J. Respir. Crit. Care Med. 2000; 162: 1905-1911Crossref PubMed Scopus (200) Google Scholar). Modification of surface charge was tested with amine-modified and carboxylated polystyrene particles, which have neutral and negative surface charges at physiological pH, respectively. The spontaneous, thermally excited motion of dozens of nanoparticles was simultaneously monitored with 5-nm spatial resolution and 33-ms temporal resolution via high resolution time-resolved epifluorescence microscopy (9.Apgar J. Tseng Y. Fedorov E. Herwig M.B. Almo S.C. Wirtz D. Biophys. J. 2000; 79: 1095-1106Abstract Full Text Full Text PDF PubMed Scopus (196) Google Scholar, 10.Tseng Y. An K.M. Wirtz D. J. Biol. Chem. 2002; 277: 18143-18150Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar, 11.Xu J. Tseng Y. Wirtz D. J. Biol. Chem. 2000; 275: 35886-35892Abstract Full Text Full Text PDF PubMed Scopus (190) Google Scholar, 12.Suh J. Wirtz D. Hanes J. Proc. Natl. Acad. Sci. U. S. A. 2003; 100: 3878-3882Crossref PubMed Scopus (337) Google Scholar). Mucolytic agents currently used clinically to reduce mucus viscosity and increase mucociliary clearance rates may be important adjuvants to gene delivery (13.Ferrari S. Kitson C. Farley R. Steel R. Marriott C. Parkins D.A. Scarpa M. Wainwright B. Evans M.J. Colledge W.H. Geddes D.M. Alton E.W. Gene Ther. 2001; 8: 1380-1386Crossref PubMed Scopus (99) Google Scholar, 14.Mrsny R. Daugherty A. Short S. Widmer R. Siegel M. Keller G. J. Drug Target. 1996; 4: 233-243Crossref PubMed Scopus (35) Google Scholar). Previous studies have focused on the effects of these agents on the transfection of cultured cells covered by non-physiological mucus gels. Because nanoparticle transport in CF sputum is typically very slow, an improved understanding of the relationship between CF mucus viscoelastic properties, which can be manipulated by mucolytic agents, and the transport of particles with a variety of surface chemistries may be critical to the design of DNA carriers for delivery in the central airways of the lung (15.Rubin B. J. Aerosol Med. 1996; 9: 123-130Crossref PubMed Scopus (23) Google Scholar). CF sputum was treated with DNase, and the effects on macroviscoelasticity and microviscoelasticity and particle transport were assessed. The viscoelasticity of CF sputum was significantly reduced after the addition of DNase, but the ensemble-averaged diffusion rate remained unchanged. However, the distribution of transport rates of individual particles was more homogeneous, demonstrating that a reduction in viscoelasticity may correspond to a reduction in heterogeneities in transport rates in CF sputum. Sputum Collection from CF Patients—Human respiratory sputum was expectorated from male and female CF patients ages 18–21 and collected by Dr. Pamela Zeitlin at the Johns Hopkins Cystic Fibrosis Research Development Center. Samples were transported on ice from the hospital to the laboratory for same day rheological characterization and particle tracking (see below). Sample collection was performed carefully to avoid contamination with salivary enzymes. Macrorheological Characterization of CF Sputum—To allow comparison with our microrheological characterization by MPT, macrorheological characterization of CF sputum was performed with a strain-controlled cone and plate rheometer (ARES-100, Rheometrics, Piscataway, NJ) using techniques described previously (16.Tseng Y. Fedorov E. McCaffery J.M. Almo S.C. Wirtz D. J. Mol. Biol. 2001; 310: 351-366Crossref PubMed Scopus (113) Google Scholar, 17.Ma L. Xu J. Coulombe P.A. Wirtz D. J. Biol. Chem. 1999; 274: 19145-19151Abstract Full Text Full Text PDF PubMed Scopus (123) Google Scholar). Small oscillatory deformations of controlled amplitude and frequency were applied to specimens to extract the frequency-dependent viscoelastic properties of CF sputum. We report the frequency-dependent elastic and viscous moduli, G′(ω) and G″(ω), which are the in-phase and out-of-phase components of the stress induced in CF sputum samples divided by the maximum amplitude of the applied deformation (typically 1%), respectively. These dynamic measurements were conducted at low deformation amplitudes to test the linear rheological properties of CF sputum, for which viscous and elastic moduli are independent of the deformation amplitude (see Fig. 1B). To test the shear viscosity of CF sputum, the rheometer was switched to steady mode and specimens were subjected to shear deformations at controlled shear rates (see Fig. 1C). The steady viscosity, η, is the ratio of the measured stress induced within the specimen and the shear rate. Error bars in Fig. 1, A–C, were computed using the mean ± S.E. for the six samples included in the macrorheological characterization of CF sputum. Multiple Particle Tracking in CF Sputum: Particle Transport Rates and Microrheology—Mode of transport (diffusive versus subdiffusive) and time-dependent diffusion coefficients of individual particles embedded in CF sputum were determined by the method of multiple particle tracking recently described for solutions of F-actin and DNA (9.Apgar J. Tseng Y. Fedorov E. Herwig M.B. Almo S.C. Wirtz D. Biophys. J. 2000; 79: 1095-1106Abstract Full Text Full Text PDF PubMed Scopus (196) Google Scholar, 10.Tseng Y. An K.M. Wirtz D. J. Biol. Chem. 2002; 277: 18143-18150Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar, 16.Tseng Y. Fedorov E. McCaffery J.M. Almo S.C. Wirtz D. J. Mol. Biol. 2001; 310: 351-366Crossref PubMed Scopus (113) Google Scholar, 18.Goodman A. Tseng Y. Wirtz D. J. Mol. Biol. 2002; 323: 199-215Crossref PubMed Scopus (57) Google Scholar) and for particle transport in live cells (12.Suh J. Wirtz D. Hanes J. Proc. Natl. Acad. Sci. U. S. A. 2003; 100: 3878-3882Crossref PubMed Scopus (337) Google Scholar, 19.Tseng Y. Kole T.P. Wirtz D. Biophys. J. 2002; 83: 3162-3176Abstract Full Text Full Text PDF PubMed Scopus (333) Google Scholar). Hundreds of fluorescently labeled carboxylated (Molecular Probes catalog numbers F8803, F8810, and F8813 for 100-, 200-, and 500-nm beads, respectively) or amine-modified (catalog number F8764) polystyrene microspheres (Molecular Probes, Eugene, OR) with highly uniform diameters of 100, 200, and 500 nm were embedded in CF sputum, and their trajectories were recorded using a silicon-intensified target camera (VE-1000, Dage-MTI, Michigan City, IN) mounted on an inverted epifluorescence microscope (Nikon) equipped with ×100 oil-immersion objective (numerical aperture 1.3). Detailed information such as particle size distributions and excitation and emission wavelengths is available from Molecular Probes. The intensity-weighted centroid of each particle was tracked with 33-ms temporal resolution and ∼5-nm spatial resolution as independently determined by tracking the apparent displacements of microspheres immobilized on a glass coverslip with a strong adhesive (9.Apgar J. Tseng Y. Fedorov E. Herwig M.B. Almo S.C. Wirtz D. Biophys. J. 2000; 79: 1095-1106Abstract Full Text Full Text PDF PubMed Scopus (196) Google Scholar). High spatial resolution of particle displacements (<1 pixel) is obtained by tracking the intensity-weighted centroid of individual particles (9.Apgar J. Tseng Y. Fedorov E. Herwig M.B. Almo S.C. Wirtz D. Biophys. J. 2000; 79: 1095-1106Abstract Full Text Full Text PDF PubMed Scopus (196) Google Scholar). Nanotracking was performed by monitoring the spontaneous, thermally excited motion of the probe nanospheres in the plane of focus of the objective. Trajectories in the focal plane are two-dimensional projections of three-dimensional displacements, i.e. we assume that CF sputum is isotropic but not necessarily homogenous. In this case, displacements of the particles along the x, y-, and z axes are uncorrelated; hence, 〈Δr2(τ)〉2D = 〈Δx2〉 + 〈Δy2〉 is simply equal to two-thirds of 〈Δr2(τ)〉3D = 〈Δx2〉 + 〈Δy2〉 + 〈Δz2〉 because 〈Δx2〉 = 〈Δy2〉 = 〈Δz2〉 (20.Berg H.C. Random Walks in Biology. Princeton University Press, Princeton, NJ1993Google Scholar). While particles may travel sometimes outside the plane of focus, it is a rare occurrence because capture times are relatively short (20 s) and mucus is a high viscosity fluid. The apparent size of particles increases as they move away from the plane of focus, but this is of no consequence since our microscope is well aligned and these out-of-plane movements do not translate into (artificial) x-y movements of the centroid of the particles. 100–150 particles were tracked for each sample with 5–20 particles in each field of view. High resolution 20-s movies of microsphere displacements were captured with a custom routine incorporated in the particle tracking software (Metamorph) as described previously (9.Apgar J. Tseng Y. Fedorov E. Herwig M.B. Almo S.C. Wirtz D. Biophys. J. 2000; 79: 1095-1106Abstract Full Text Full Text PDF PubMed Scopus (196) Google Scholar, 10.Tseng Y. An K.M. Wirtz D. J. Biol. Chem. 2002; 277: 18143-18150Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar, 19.Tseng Y. Kole T.P. Wirtz D. Biophys. J. 2002; 83: 3162-3176Abstract Full Text Full Text PDF PubMed Scopus (333) Google Scholar). The mean squared displacements of individual particles were computed from microsphere trajectories using an Excel Macros routine (9.Apgar J. Tseng Y. Fedorov E. Herwig M.B. Almo S.C. Wirtz D. Biophys. J. 2000; 79: 1095-1106Abstract Full Text Full Text PDF PubMed Scopus (196) Google Scholar, 21.Tseng Y. Wirtz D. Biophys. J. 2001; 81: 1643-1656Abstract Full Text Full Text PDF PubMed Scopus (134) Google Scholar). All of the MPT measurements were conducted in a temperature-controlled microscope chamber maintained at 37 °C. The coordinates of the microsphere centroids were transformed into families of time-averaged mean squared displacements (MSD), 〈Δr2(τ)〉 = 〈[x(t + τ) – x(t)]2 + [y(t + τ) – y(t)]2〉 (τ = time scale or time lag), from which distributions of MSDs, time-dependent particle diffusion coefficients, and apparent local microviscosities of the sputum samples were calculated (10.Tseng Y. An K.M. Wirtz D. J. Biol. Chem. 2002; 277: 18143-18150Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar, 22.Mason T.G. Ganesan K. van Zanten J.H. Wirtz D. Kuo S.C. Phys. Rev. Lett. 1997; 79: 3282-3285Crossref Scopus (687) Google Scholar). Recombinant Human DNase Treatment—CF sputum was treated ex vivo with a mucolytic agent, recombinant human deoxyribonuclease (rhDNase), at a concentration of 7 μg/ml, which is the estimated in vivo concentration (14.Mrsny R. Daugherty A. Short S. Widmer R. Siegel M. Keller G. J. Drug Target. 1996; 4: 233-243Crossref PubMed Scopus (35) Google Scholar). Particle tracking (providing particle transport rates and CF sputum microrheology) and macrorheological characterization of CF sputum were performed before and 30 min after the administration of rhDNase. Four-dimensional (x, y, z, and t) Laser Scanning Confocal Microscopy—Confocal images of particles embedded in CF sputum were captured with an AxioCAM HR camera attached to a Zeiss LSM 510 Meta laser-scanning confocal microscope. The stock solution is 1% by volume of particles, which was diluted 100-fold. The final concentration by volume of the particles in mucus was 0.03%. Sputum was placed in a Bioptechs thermal regulated chamber (Bioptechs, Butler, PA) maintained at 37 °C and imaged before and 30–120 min after treatment with rhDNase. To assess qualitatively particle mobility in CF sputum after the addition of mucolytic agents, particles dispersed throughout sputum samples were imaged in four dimensions (with a time interval of ∼5 min). ζ Potential Measurements—The surface potentials of amine-modified and carboxylated polystyrene particles (pH 4–8) were measured by particle electrophoresis (Zetasizer 2000, Malvern, PA). The pH of particle suspensions (100 μl of solution, 0.02% particles diluted in 3 ml of 150 mm NaCl) was adjusted prior to measuring the ζ potentials with hydrochloric acid and sodium hydroxide solutions. Transmission Electron Microscopy—Specimens were prepared by diluting (1:10) fresh CF sputum with sputum buffer (pH 7.4) (5.Sanders N.N. De Smedt S.C. Van Rompaey E. Simoens P. De Baets F. Demeester J. Am. J. Respir. Crit. Care Med. 2000; 162: 1905-1911Crossref PubMed Scopus (200) Google Scholar) and allowing to stir at 4 °C for 1 h prior to imaging. Sputum was adsorbed to ionized Formvar grids, negatively stained with uranyl acetate, and observed using a Philips LS420 transmission electron microscope. Macrorheological Properties of CF Sputum—To allow a comparison with the novel characterization of the microrheological properties of CF sputum by MPT, the overall macroscopic viscoelasticity of CF sputum was first characterized using a sensitive strain-controlled cone and plate rheometer. The dynamic response of CF sputum to shear was tested by applying oscillatory deformations of small amplitude (see “Experimental Procedures”). The viscous modulus, G″(ω), of CF sputum remained relatively independent of frequency over a range of 0.01–100 rad/s while the elastic modulus, G′(ω), increased steadily with frequency over the same range (Fig. 1A). Therefore, the elastic resistance of CF sputum to shear deformation increased when subjected to increasing rates of deformation. The elastic modulus of CF sputum was much higher than the viscous modulus over the entire tested range of frequency (Fig. 1A), indicating that CF sputum behaves as a viscoelastic solid when probed by macrorheological techniques. Interestingly, the elastic modulus at low and intermediate frequency adopted approximately a power law behavior as determined by the slope of G′(ω) on a log-log plot, G′(ω)∼ω½ (Fig. 1A). This characteristic exponent suggests that sputum macromolecules behave like flexible polymers (G′(ω)∼ωn; n = 1 for a rigid polymer, n = 0.75 for a semi-rigid polymer, and n = 0.5 for a flexible polymer) (23.Palmer A. Xu J. Kuo S.C. Wirtz D. Biophys. J. 1999; 76: 1063-1071Abstract Full Text Full Text PDF PubMed Scopus (182) Google Scholar). The mechanical response of CF sputum to shear was assayed by subjecting specimen to shear deformations of fixed frequency and increasing deformation amplitudes (Fig. 1B). Elastic and viscous moduli of CF sputum were independent of deformations up to strain amplitudes of ∼10% and progressively softened beyond that threshold amplitude (Fig. 1B). The macroscopic viscoelastic character of CF sputum may be characterized by computing the phase angle, δ = tan–1(G″/G′). A phase angle of δ = 0, 90°, or between 0 and 90° indicates that a material behaves like a Hookean solid, viscous liquid, or viscoelastic gel, respectively. The phase angle of human CF sputum (n = 6) was 16.2 ± 0.6° (at ω = 1 rad/s). This result confirms that CF mucus is significantly more elastic than viscous, a signature of viscoelastic-solid behavior. The steady state viscosity of CF sputum was measured by subjecting specimen to steady state deformations of controlled shear rate (Fig. 1C). At shear rates of <1 s–1, CF sputum displayed slight shear thickening behavior with a (mean) maximum sputum macroviscosity of ∼700 Poise or 7 × 104 times the viscosity of water (Fig. 1C at a shear rate of 0.2 s–1). CF sputum samples varied from patient to patient, as illustrated by variations in the steady state viscosities (Fig. 1C, inset). Transport of Individual Particles in CF Sputum—The coordinates of the centroids of hundreds of fluorescent microspheres embedded in CF sputum were captured and transformed into families of time-averaged MSDs, 〈Δr2(τ)〉 = 〈[x(Δt + τ) – x(Δt)]2 + [y(Δt+τ) –y(Δt)]2〉 (τ = time scale or time lag; t = elapsed time), from which distributions of MSDs, time-dependent particle diffusion coefficients, and apparent local microviscosities of the sputum samples were calculated (10.Tseng Y. An K.M. Wirtz D. J. Biol. Chem. 2002; 277: 18143-18150Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar, 22.Mason T.G. Ganesan K. van Zanten J.H. Wirtz D. Kuo S.C. Phys. Rev. Lett. 1997; 79: 3282-3285Crossref Scopus (687) Google Scholar). Individual particle MSDs were used to determine averaged (or “ensemble-averaged”) MSD, allowing variation in particle transport rates in CF sputum to be directly measured for the first time. The ensemble MSD of 100, 200, and 500 nm particles in CF sputum samples (n = 3 sputum samples/particle size; n ≥ 100 particles/sample) did not have a linear dependence on time (Fig. 2A) as would occur in a purely viscous medium. Particle transport rates in CF sputum decreased with time (Fig. 2B). The product of particle size, a, and its MSD as a function of time scale was approximately the same for 100-, 200-, and 500-nm particles (with the exception of the slope of the MSD*a for 500-nm particles), indicating that the diffusion coefficient varies approximately as the inverse of the particle diameter as predicted by the classical Stokes-Einstein relation (Fig. 2C) (see “Discussion”). A large variation in transport rates for individual particles was observed in CF sputum, especially for 100- and 200-nm particles (Fig. 3, A, C, and E). The distributions of individual particle MSDs at Δt = 0.1 s for 100-, 200-, and 500-nm-diameter particles (Fig. 3, B, D, and F) were used to quantify the heterogeneity of particle transport rates as a function of bead size. In addition to being slower on average, particle transport became more homogeneous with increasing bead size. The percentage of 100-, 200-, and 500-nm particles with transport rates within 2% of their ensemble averaged MSDs were 28, 36, and 56%, respectively (Fig. 3). Furthermore, the majority of 100- and 200-nm particles (80 and 85%, respectively) had transport rates that were less than their ensemble average, whereas only 30% of 500-nm particles transported more slowly than their ensemble average. However, a small fraction of 100- and 200-nm particles (1.6 and 2.1%) had transport rates 10–40-fold higher than their ensemble averages, whereas 0% of 500-nm particles exhibited rates faster than 8-fold higher than their ensemble average. Microviscosities versus Macroviscosities—Although nanoparticle transport rates are time-dependent in CF sputum, transport rates of 100- and 200-nm particles at Δt = 10 s are primarily diffusive as determined by the linearity of the slope of the MSD (Fig. 2A). This observation allowed us to calculate an effective microviscosity encountered by 100- and 200-nm particles in CF sputum from their diffusion coefficients, D(Δt), at Δt = 10 s using the Stokes-Einstein equation. The microviscosity of CF sputum probed by 100- and 200-nm particles was 15- and 7-fold lower, respectively, than its macroviscosity, as measured by a cone and plate rheometer (Fig. 4A). This difference indicates that particle transport is significantly more rapid than would be expected from standard macrorheological measurements of viscosity. The microviscosity of CF sputum may, therefore, reflect the viscosity encountered by particles moving in fluid-filled pores of the CF sputum mesh (Fig. 4B). Effects of rhDNase Treatment on Particle Transport Rate and Macrorheology in CF Sputum—The high DNA concentration in CF sputum is known to increase the viscosity of the gel and may potentially decrease particle transport rates. Therefore, rhDNase (Pulmozyme) was added (7 μg/ml) to human CF sputum (14.Mrsny R. Daugherty A. Short S. Widmer R. Siegel M. Keller G. J. Drug Target. 1996; 4: 233-243Crossref PubMed Scopus (35) Google Scholar) and the macrorheological properties of and 200-nm particle transport rates within CF sputum were determined. The macroscopic elasticity (Fig. 5A) was reduced ∼50%, and the macroscopic viscosity (at a shear rate of 1 s–1) was reduced by ∼40% (Fig. 5B). Surprisingly, the average rate of particle transport was not altered for 200-nm particles despite the dramatic decrease in the macrorheological properties of CF sputum 30 min after the addition of rhDNase (Fig. 5C). However, randomly selected MSDs of 200-nm particles (n = 20 of 120 total) before (Fig. 6A) and 30 min after (Fig. 6C) the addition of rhDNase showed that particle transport rates were more homogeneous after the addition of rhDNase. These arbitrarily selected MSDs constituted an accurate representation of the distributions of MSDs, because the number of particles with MSDs close to the ensemble-averaged MSD increased by ∼20% (same results for Δt = 0.1 s) (Fig. 6, B and D). As expected, we observed similar results with 100-nm nanoparticles, whereas 500-nm nanoparticles saw little change in the heterogeneity of their diffusivities, perhaps because those particles are much larger than the average pore size whose microviscosity is increased by rhDNase treatment (data not shown).Fig. 6A–D, effect of rhDNase (Pulmozyme) treatment (7 μg/ml) on the transport properties of individual 200-nm carboxylated polystyrene particles in CF mucus (120 particles for each condition). 20 MSD profiles of a subset (20 of 120) of individual particles for no treatment (A) and 30 min after rhDNase treatment (C) are shown. The distributions of normalized MSDs for no rhDNase treatment (B) and 30 min after rhDNase treatment (D) are shown.View Large Image Figure ViewerDownload Hi-res image Download (PPT) Effects of Surface Charge on Particle Transport Rates—The adhesivity of amine-modified and carboxylated 200-nm-diameter polystyrene particles to CF sputum was assessed qualitatively by confocal microscopy. Both amine-modified and carboxylated particles were partly adhesive to CF sputum (Fig. 7A), which may be due in part to the hydrophobicity of the polystyrene core. Note that these interactions affect mostly the nature of transport (diffusive versus subdiffusive) at short time scales, but transport remains diffusive at long time scales albeit with much smaller diffusion coefficients than expected in buffer. Despite the similarities in adhesivity of these particles, the surface chemistry imparted large differences in the particle surface charge with the amine-modified particles having a more neutral charge (–4.6 ± 0.4 mV) at physiological pH than the negatively charged carboxylated polys
Referência(s)