Artigo Revisado por pares

MANAGEMENT OF IMPENDING PENILE PROSTHESIS EROSION WITH A POLYTETRAFLUOROETHYLENE DISTAL WIND SOCK GRAFT

1998; Lippincott Williams & Wilkins; Volume: 160; Issue: 6 Part 1 Linguagem: Inglês

10.1016/s0022-5347(01)62237-7

ISSN

1527-3792

Autores

Christopher P. Smith, Stephen R. Kraus, Timothy B. Boone,

Tópico(s)

Genital Health and Disease

Resumo

No AccessJournal of UrologyClinical Urology: Original Articles1 Dec 1998MANAGEMENT OF IMPENDING PENILE PROSTHESIS EROSION WITH A POLYTETRAFLUOROETHYLENE DISTAL WIND SOCK GRAFT CHRISTOPHER P. SMITH, STEPHEN R. KRAUS, and TIMOTHY B. BOONE CHRISTOPHER P. SMITHCHRISTOPHER P. SMITH More articles by this author , STEPHEN R. KRAUSSTEPHEN R. KRAUS More articles by this author , and TIMOTHY B. BOONETIMOTHY B. BOONE More articles by this author View All Author Informationhttps://doi.org/10.1016/S0022-5347(01)62237-7AboutFull TextPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract Purpose: Erosion of penile prostheses can be calamitous, often leaving patients unable to accommodate further implants. There is a paucity of literature describing impending erosion of penile prosthesis. We report on 5 patients with impending erosion of a penile prosthesis who underwent polytetrafluoroethylene distal wind sock graft placement. Materials and Methods: From 1993 to 1997, 5 patients with a mean age of 49 years and impending penile prosthesis erosion underwent 6 revisions using a polytetrafluoroethylene distal wind sock graft. Two patients underwent simultaneous bilateral grafts while 1 patient underwent separate right and left grafts 3 years apart. Indications for reconstruction included distal migration of the prosthetic cylinders into the glans in 4 patients and impingement of the distal urethra in 2. Of the patients 3 were spinal cord injured, 1 had lumbar radiculopathy and 1 had a history of pelvic irradiation. Inflatable prostheses were implanted in 4 patients, while 1 received a malleable prosthesis. Results: Patients underwent a mean of 1.5 penile prosthetic revisions (0 to 4) before diagnosis of impending erosion. An interval of 8 to 144 months (mean 66) elapsed from the most recent penile prosthesis insertion until distal wind sock graft placement. Mean operative time was 1 hour 51 minutes (1.3 to 2.5 hours). Mean hospital stay was 6.3 days (3 to 12). At a mean followup of 32 months (0.7 to 5.2 years) all patients had satisfactory and functional erections with no pain or evidence of impending erosion or penile prosthesis infection. Conclusions: Erosion of a penile prosthesis can have disastrous consequences. We describe a safe and effective technique for managing impending penile prosthesis erosion using a polytetrafluoroethylene distal wind sock graft. References 1 : Repair of distal extrusion of a penile prosthesis. Contemp. Urol.1998; 10: 13. Google Scholar 2 : Marlex replacement of tunica albuginea. J. Urol.1980; 124: 732. Link, Google Scholar 3 : Complications of penile prosthesis surgery for impotence. J. Urol.1982; 128: 1192. Link, Google Scholar 4 : Complicated implantations of inflatable penile prostheses. Urol. Clin. N. Amer.1987; 14: 217. Google Scholar 5 : Use of a polytetrafluoroethylene tube graft as a circumferential neotunica during placement of a penile prosthesis. J. Urol.1992; 148: 1531. Link, Google Scholar 6 : Use of a prefabricated tunica vaginalis fascia flap to reconstruct the tunica albuginea after recurrent penile prosthesis extrusion. J. Urol.1998; 159: 128. Link, Google Scholar 7 : Complications of penile prostheses in spinal cord injury population. J. Urol.1988; 140: 984. Link, Google Scholar 8 : Erosion of malleable penile prosthesis into bladder. J. Urol.1997; 157: 2259. Link, Google Scholar 9 : Anatomy and strength of the tunica albuginea: its relevance to penile prosthesis extrusion. J. Urol.1994; 151: 1205. Link, Google Scholar 10 : Penile corporoplasty with polytetrafluoroethylene (PTFE) grafts. Urology1983; 22: 46. Google Scholar 11 : Comparison of the use of a downsized inflatable penile prosthesis vs. prosthetic implantation with Gore-Tex grafting for nondilatable cavernosal fibrosis. J. Urol.1993; 149: 355A. abstract 571. Google Scholar 12 : Penile prosthesis implantation in total phaloplasty. J. Urol.1994; 152: 410. Link, Google Scholar 13 : Simultaneous Ultrex penile prosthesis reimplantation and Gore-Tex grafting corporoplasty: functional outcomes of a surgical challenge. J. Urol.1995; 153: 361A. abstract 530. Google Scholar 14 : Penile prosthesis insertion with corporeal reconstruction with synthetic vascular graft material. J. Urol.1995; 154: 80. Link, Google Scholar 15 : Prosthesis placement after total phallic reconstruction. J. Urol.1993; 149: 593. Link, Google Scholar 16 : A technique of maintaining penile prosthesis position to prevent proximal migration. J. Urol.1987; 137: 294. Link, Google Scholar 17 : The management of extensive penile fibrosis: a new technique of minimal scar-tissue excision. Brit. J. Urol.1996; 77: 282. Google Scholar 18 : Risk factors for penile prosthetic infection. J. Urol.1996; 156: 402. Link, Google Scholar 19 : Urologic prostheses. Emer. Med. Clin. N. Amer.1994; 12: 729. Google Scholar From the Scott Department of Urology, Baylor College of Medicine, Houston, Texas© 1998 by American Urological Association, Inc.FiguresReferencesRelatedDetailsCited byFerguson G and Brandes S (2007) Gunshot Wound Injury of the Testis: The Use of Tunica Vaginalis and Polytetrafluoroethylene Grafts for ReconstructionJournal of Urology, VOL. 178, NO. 6, (2462-2465), Online publication date: 1-Dec-2007.SZOSTAK M, PIZZO J and SKLAR G (2018) THE PLUG AND PATCH: A NEW TECHNIQUE FOR REPAIR OF CORPORAL PERFORATION DURING PLACEMENT OF PENILE PROSTHESESJournal of Urology, VOL. 163, NO. 4, (1203-1205), Online publication date: 1-Apr-2000. Volume 160Issue 6 Part 1December 1998Page: 2037-2040 Advertisement Copyright & Permissions© 1998 by American Urological Association, Inc.MetricsAuthor Information CHRISTOPHER P. SMITH More articles by this author STEPHEN R. KRAUS More articles by this author TIMOTHY B. BOONE More articles by this author Expand All Advertisement PDF downloadLoading ...

Referência(s)
Altmetric
PlumX