Artigo Revisado por pares

Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study

2011; Elsevier BV; Volume: 21; Issue: 5 Linguagem: Inglês

10.1016/j.jse.2011.04.013

ISSN

1532-6500

Autores

Sven-Oliver Dietz, Frank Hartmann, Thomas Schwarz, Tobias E. Nowak, A. Enders, Sebastian Kühn, Alexander Hofmann, Pol Maria Rommens,

Tópico(s)

Bone fractures and treatments

Resumo

Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calculate the initial stiffness and exclude pairs with differences. Afterward, an unstable proximal humeral fracture (AO 11-A3) was created by means of an oscillating saw, and the respective osteosynthesis devices were implanted. After another 4 cycles, initial changes in stiffness were measured. Subsequently, all specimens were tested for 1,000 cycles of loading before final stiffness was assessed. Results We found no statistically significant differences between Retron and Philos specimens after 4 or 1,000 cycles of loading. Conclusion Our study suggests that retrograde nailing provides sufficient stability for axial and torsional loading in 2-part fractures of proximal humeri. In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calculate the initial stiffness and exclude pairs with differences. Afterward, an unstable proximal humeral fracture (AO 11-A3) was created by means of an oscillating saw, and the respective osteosynthesis devices were implanted. After another 4 cycles, initial changes in stiffness were measured. Subsequently, all specimens were tested for 1,000 cycles of loading before final stiffness was assessed. We found no statistically significant differences between Retron and Philos specimens after 4 or 1,000 cycles of loading. Our study suggests that retrograde nailing provides sufficient stability for axial and torsional loading in 2-part fractures of proximal humeri.

Referência(s)