Artigo Revisado por pares

Initial experience with 99m Tc-hexamethyl-propylene amine oxime (HM-PAO) single photon emission computedtomography (SPECT) in patients with focal epilepsy

1987; Elsevier BV; Volume: 1; Issue: 2 Linguagem: Inglês

10.1016/0920-1211(87)90019-2

ISSN

1872-6844

Autores

Hermann Stefan, C. Kuhnen, H.-J. Biersack, K. Reichmann,

Tópico(s)

Radiopharmaceutical Chemistry and Applications

Resumo

Brain single photon emission computed tomography (SPECT) was performed in 16 patients with focal epilepsy, as well as EEG, using 99m Tc-HM-PAO SPECT and a rotating gamma camera system. Pathological Tc-HM-PAO SPECT findings were registered in 75%. CT was positive in 25%. MRI was positive in 76%. The results of Tc-HM-PAO SPECT findings were compared with those of CT and MRI. 61% of the MRI findings correlated with the pathological SPECT findings with respect to the side of the hemisphere, and in 75% of the patients the focal EEG abnormality and the pathological Tc-HM-PAO-SPECT findings were localized in the same hemisphere.