Artigo Revisado por pares

High Performance Liquid Chromatographic Assay of Methoclopramide in Plasma Using a Silica Gel Column and An Aqueous Meobile Phase

1987; Taylor & Francis; Volume: 20; Issue: 1 Linguagem: Inglês

10.1080/00032718708082241

ISSN

1532-236X

Autores

Robert Shi, Winnia L. Gee, Roger Williams, Emit T. Lin,

Tópico(s)

Antibiotics Pharmacokinetics and Efficacy

Resumo

Abstract A high performance liquid chromatographic method for quantitating matoclopramide in plasma is presented. Proteins ara precipitated from the plasma sample with acetonitri la containing the internal standard, procainamida. The treated samples ara than analyzad using an Ultrasphere Si column, an aqueous solution at pH 7 of 65% CH3CN and 5.0 mM (NH4)2HPO4 as a mobile phase, and a fluorescence detector. The retention times for drug and intarna1 standard ara 11.2 and 13.2 min, respectively. The caibration curve is Linear from 0.89 to 44.5 ng/ml. The detection limit is 0.89 ng/ml [signaL/hoisa = 31] for 0.2 ml plasma samples Pracision is measured by intraday and intarday coefficients o f variation, which are less than 10%. This method is currently being used for pharmacokinetic studies of methoclopramide.