Failure Analysis Of Synathetic Insulators With Fiberglass Rod Submitted To Mechanical Loads
1983; Institute of Electrical and Electronics Engineers; Volume: PAS-102; Issue: 9 Linguagem: Inglês
10.1109/tpas.1983.318119
ISSN0018-9510
AutoresRafael Mier-Maza, Jacques Lanteigne, C.H. de Tourreil,
Tópico(s)Structural Analysis of Composite Materials
ResumoFour end fitting designs of long rod fiberglass core suspension insulators are studied and the failure mechanisms are analyzed after UTS and creep tests. The fracture occurs in the fiberglass rod due to the stresses induced by the metal part of the endfitting that hold the insulating components.