Artigo Revisado por pares

Voltammetric determination of the metal complexing capacity in model solutions

1996; Elsevier BV; Volume: 53; Issue: 1-2 Linguagem: Inglês

10.1016/0304-4203(96)00018-7

ISSN

1872-7581

Autores

Dario Omanović, Ivanka Pižeta, Željko Peharec, Marko Branica,

Tópico(s)

Conducting polymers and applications

Resumo

Determination of the metal complexing capacity (MCC) has been carried out in model solutions of 0.55 mol l−1 NaCl using anodic stripping voltammetry by two different working electrode assemblies: Static Mercury Drop Electrode (SMDE) and Thin Mercury Film Glassy Carbon Disk Electrode (TMFGCDE). The separation of the reduction potentials of free ions and labile copper(II) complexes vs. the inert one (Cu-EDTA) at SMDE is achieved by the addition of l mg l−1 of Triton-X-100. The appropriate deposition potential for copper complexing capacity (CuCC) determination has been established from the pseudopolarograms. TMFGCDE yields better separation of those reduction processes, when thinner film of mercury is applied without addition of surfactants. The determination limit of 10−7 mol l−1 CuCC with SMDE was found. The results obtained with model solution show lower CuCC values than expected. This can be attributed to the partial dissociation of an inert Cu-EDTA complex during the transport through a rather thick diffusion layer formed with SMDE devices. The determination limit of 10−8 mol l−1 MCC (Cd, Pb, Cu) with TMFGCDE was found. The MCC values obtained in the model solution were higher than expected due to the cell's ‘blank capacity’.

Referência(s)
Altmetric
PlumX