Editorial Revisado por pares

Paediatric anaesthetic breathing systems

1996; Wiley; Volume: 6; Issue: 1 Linguagem: Inglês

10.1111/j.1460-9592.1996.tb00343.x

ISSN

1460-9592

Autores

Yu-Chun Lin, John G. Brock‐Utne,

Tópico(s)

Anesthesia and Sedative Agents

Resumo

Pediatric AnesthesiaVolume 6, Issue 1 p. 1-5 Paediatric anaesthetic breathing systems Y.-C. Lin, Y.-C. Lin Anesthesia Department, H3580, Stanford University Medical Center, Stanford, CA 94305-5115 USASearch for more papers by this authorJ.G. Brock-Utne, J.G. Brock-Utne Anesthesia Department, H3580, Stanford University Medical Center, Stanford, CA 94305-5115 USASearch for more papers by this author Y.-C. Lin, Y.-C. Lin Anesthesia Department, H3580, Stanford University Medical Center, Stanford, CA 94305-5115 USASearch for more papers by this authorJ.G. Brock-Utne, J.G. Brock-Utne Anesthesia Department, H3580, Stanford University Medical Center, Stanford, CA 94305-5115 USASearch for more papers by this author First published: January 1996 https://doi.org/10.1111/j.1460-9592.1996.tb00343.xCitations: 13AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onEmailFacebookTwitterLinkedInRedditWechat References Artru A.A. & Katz R.A. (1987) Evaluation of the Humphrey ADE breathing system. Canadian Journal of Anaesthesia. 34, 484–488. 10.1007/BF03014355 CASPubMedWeb of Science®Google Scholar Ayre P. (1937) Anaesthesia for intracranial operation. Lancet. i, 561–563. 10.1016/S0140-6736(00)97709-2 Google Scholar Bain J.A. & Spoerel W.E. (1972) A streamlined anaesthetic system. Canadian Anaesthetists Society Journal. 19(4), 4–426. 10.1007/BF03005967 Web of Science®Google Scholar Bradley J.P., Marsland A. & Salkield I.M. (1985) The multicircuit system 2. A study during spontaneous ventilation in awake volunteers using the Mapleson A mode. Anaesthesia and Intensive Care. 13, 158–162. 10.1177/0310057X8501300208 CASPubMedWeb of Science®Google Scholar Brock-Utne J.G., Downing J.W. & Holloway D.M. (1980) A performance evaluation of the Samson Paediatric Anaesthetic Set. South African Medical Journal. 58, 294–296. CASPubMedWeb of Science®Google Scholar Burchett K.R. & Bennett J.A. (1985) A new co-axial breathing system. Anaesthesia. 40, 181–187. 10.1111/j.1365-2044.1985.tb10712.x CASPubMedWeb of Science®Google Scholar Byrick R.J. & Rose D.K. (1986) Will we ever have a universal anaesthetic breathing system Canadian Anaesthetists Society Journal. 33, 694–697. 10.1007/BF03027116 CASPubMedWeb of Science®Google Scholar Christensen K.N., Thomsen A., Hansen O. & Jörgensen S. (1978) Flow requirements is the Hafria modifications of the Mapleson circuits during spontaneous respiration. Acta Anaesthesiologica Scandinavica. 22, 27–32. 10.1111/j.1399-6576.1978.tb01276.x CASPubMedWeb of Science®Google Scholar Conterato J.P., Lindahl S.G.E., Meyer D.M. & Bires J.A. (1989) Assessment of spontaneous ventilation in anesthetized children with use of a pediatric circle or a Jackson Rees system. Anesthesia and Analgesia. 69, 484–490. 10.1213/00000539-198910000-00010 CASPubMedWeb of Science®Google Scholar Conway C.M. (1974) Anaesthetic circuits. In C. Scurr, S. Feldman (Eds). Scientific Foundations of Anaesthesia, 2nd edn, pp 509. William Heineman Medical Books, London . Google Scholar Conway C.M. (1985) A new co-axial breathing system. Anaesthesia. 40, 1135–1136. 10.1111/j.1365-2044.1985.tb10630.x PubMedWeb of Science®Google Scholar Criswell J., McKenzie S., Day S., Disley J., Bruce W.E. & Soni N. (1990) The Bain, ADE and enclosed Magill breathing systems. A comparative study during controlled ventilation. Anaesthesia. 47, 113–117. 10.1111/j.1365-2044.1990.tb14273.x Web of Science®Google Scholar Dixon J., Chakrabati M.K. & Morgan M. (1984) An assessment of the Humphrey ADE anaesthetic system in the Mapleson A mode during spontaneous ventilation. Anaesthesia. 39, 593–596. 10.1111/j.1365-2044.1984.tb07371.x PubMedWeb of Science®Google Scholar Dorsch J.A. & Dorsch S.E. (1994) Understanding anesthesia equipment construction care and complication, 3rd edn., p. 162. Williams & Wilkins, Baltimore . Google Scholar Flynn P.J. & Morris L.E. (1980) Humidity in anaesthetic system. British Journal of Anaesthesia. 53, 1096. PubMedWeb of Science®Google Scholar Henville J.D. & Adams A.P. (1976) The Bain anaesthetic system. Anaesthesia. 31, 247–256. 10.1111/j.1365-2044.1976.tb11798.x CASPubMedWeb of Science®Google Scholar Humphrey D. (1982) The Lack, Magill and Bain anaesthetic breathing systems (a direct comparison in spontaneously breathing anaesthetized adults). Journal of the Royal Society of Medicine. 75, 513–524. CASPubMedWeb of Science®Google Scholar Humphrey D. (1983) A new anaesthetic breathing system combining Mapleson A, D and E principles, a simple apparatus for low flow universal use without carbon dioxide absorption. Anaesthesia. 38, 361–371. 10.1111/j.1365-2044.1983.tb10462.x CASPubMedWeb of Science®Google Scholar Humphrey D. (1985) A new co-axial breathing system. Anaesthesia. 40, 1136–1137. Web of Science®Google Scholar Humphrey D., Brock-Utne J.G. & Downing J.W. (1986a) Single lever Humphrey ADE low flow universal anaesthetic breathing system (part 1). Canadian Anaesthetists Society Journal. 33, 698–709. 10.1007/BF03027118 CASPubMedWeb of Science®Google Scholar Humphrey D., Brock-Utne J.G. & Downing J.W. (1986b) Single lever Humphrey ADE low flow universal anaesthetic breathing system (part 2). Canadian Anaesthetists Society Journal. 33, 698–709. 10.1007/BF03027118 CASPubMedWeb of Science®Google Scholar Jackson Rees G. (1950) Anaesthesia in the new born. Medical Journal. 1, 1419–1422. 10.1136/bmj.2.4694.1419 Google Scholar Jaffe R.A., Pinto F.J., Schnittger I., Siegel L.C., Wranne B. & Brock-Utne J.G. (1992) Aspects of mechanical ventilation affecting interatrial shunt flow during general anesthesia. Anesthesia and Analgesia. 75, 484–488. 10.1213/00000539-199210000-00003 CASPubMedWeb of Science®Google Scholar Jarvis D. & Brock-Utne J.G. (1991) The use of an oxygen concentrator linked to a draw-over vaporizer (anesthesia delivery system for underdeveloped nations). Anesthesia and Analgesia. 72, 805–810. 10.1213/00000539-199106000-00016 CASPubMedWeb of Science®Google Scholar Jörgenson S. & Thomsen A. (1976) The Hafria A circuit. A valve-less non-polluting anaesthetic system. Acta Anaesthesiologica Scandinavica. 20, 395–404. 10.1111/j.1399-6576.1976.tb05056.x CASPubMedWeb of Science®Google Scholar Kain M.L. & Nunn J.F. (1968) Fresh gas economics of the Magill circuit. Anesthesiology. 29, 964. 10.1097/00000542-196809000-00021 PubMedWeb of Science®Google Scholar Lack J.A. (1976a) Theatre pollution control. Anaesthesia. 31, 259–262. 10.1111/j.1365-2044.1976.tb11800.x PubMedWeb of Science®Google Scholar Lack J.A. (1976b) Pollution control by co-axial circuits. Anaesthesia. 31, 561. 10.1111/j.1365-2044.1976.tb12372.x PubMedWeb of Science®Google Scholar Mapleson W.W. (1954) The elimination of rebreathing in various semi-closed anaesthetic systems. British Journal of Anaesthesia. 26, 323–332. 10.1093/bja/26.5.323 PubMedGoogle Scholar Miller D.M. (1979) A new universal anaesthetic circuit using a preferential flow T-piece. South African Medical Journal. 55, 721–725. CASPubMedWeb of Science®Google Scholar Miller D.M. & Cooper J.L. (1983) Comparison of the fresh gas flow requirements and resistance of the preferential flow system with those of the Magill system. British Journal of Anaesthesia. 55, 569–574. 10.1093/bja/55.6.569 CASPubMedWeb of Science®Google Scholar Orlikowski C.E.P., Ewart M.C. & Bingham R.M. (1991) The Humphrey ADE system: Evaluation in paediatric use. British Journal of Anaesthesia. 66, 253–257. 10.1093/bja/66.2.253 CASPubMedWeb of Science®Google Scholar Rasch D.K., Bunegin L., Ledbetter J. & Kaminskas D. (1988) Comparison of a circle absorber and Jackson Rees systems for paediatric anaesthesia. Canadian Journal of Anaesthetists. 35(1), 1–25. Google Scholar Salkield I.M. (1985) The multicircuit system 1. Description of a device providing several Mapleson functions. Anaesthesia and Intensive Care. 13, 153–157. 10.1177/0310057X8501300207 CASPubMedWeb of Science®Google Scholar Samson H.H. (1965) The Samson Paediatric Anaesthetic Set. South African Medical Journal. 39, 330–331. CASPubMedGoogle Scholar Shah N.K., Loughlin C.J. & Bedford R.F. (1989) Comparison of the Bain and the ADE systems during controlled ventilation in adults. British Journal of Anaesthesia. 62, 150–152. 10.1093/bja/62.2.150 CASPubMedWeb of Science®Google Scholar Shulman M.S. & Brodsky J.B. (1984) The ADE system—a new anesthetic breathing system. Anesthesia and Analgesia. 63, 273. Web of Science®Google Scholar Steven J.M. & Cohen D.E. (1990) Anesthesia equipment and monitoring. In Smith's Anesthesia for Infants & Children 5th edn, chapter 8, pp. 217–256. Google Scholar Sykes M.K. (1968) Rebreathing circuits: a review. British Journal of Anaesthesia. 40, 666. 10.1093/bja/40.9.666 Web of Science®Google Scholar Wilkes P.R. & Lindsay P.A. (1994) Bain circuit occluded by foreign body. Canadian Journal of Anaesthesia. 41, 137–139. 10.1007/BF03009807 PubMedWeb of Science®Google Scholar Wills B.A., Pender J.W.M. & Mapleson W.W. (1975) Rebreathing in a T-piece, volunteer and theoretical studies of the Jackson Rees Modification of Ayres T-piece during spontaneous respiration. British Journal of Anaesthesia. 47, 1239–1562. 10.1093/bja/47.12.1239 CASPubMedWeb of Science®Google Scholar Citing Literature Volume6, Issue1January 1996Pages 1-5 ReferencesRelatedInformation

Referência(s)
Altmetric
PlumX