Mammographic Dosimetry Using MCNP-4B
2000; Taylor & Francis; Volume: 37; Issue: sup1 Linguagem: Inglês
10.1080/00223131.2000.10875015
ISSN1881-1248
AutoresG. Verdú, Antonio de la Vega de León, J.I. Villaescusa, Maribel Salas, M D Cuevas, Franklin Rivera Bueno,
Tópico(s)Advanced X-ray and CT Imaging
ResumoThree doses involved in the female breast, Adipose, Glandular and Total Doses, were calculated for different adipose tissue ratio and four breast thickness using MCNP-4B code. Glandular Dose is the most important contribution to the breast carcinogenesis risk. As breast composition changes with woman age, a function that relates age with dose has been estimated. For all thickness, the calculated results have shown the dependence of both parameters. A different behaviour of Adipose and Glandular doses for different four breast thickness has been observed, basically due to backscattering dose in the outer adipose tissue region and the thickness-distance X-ray source effect.