Artigo Revisado por pares

MODIFICATION OF LANTHANUM OXYCHLORIDE SOLID ELECTROLYTE FOR CONVENTIONAL POTENTIOMETRIC CHLORINE GAS SENSOR

2011; World Scientific; Volume: 04; Issue: 02 Linguagem: Inglês

10.1142/s179360471100183x

ISSN

1793-6047

Autores

M. Dziubaniuk, P. Pasierb, M. Rękas,

Tópico(s)

Electronic and Structural Properties of Oxides

Resumo

La 1-x Mg x OCl 1-x (x = 0.025, 0.05 and 0.1) and La 0.9 Ca 0.1 OCl 0.9 samples were prepared by a solid state reaction method. The best preparation conditions were determined by means of the differential thermal analysis and thermogravimetry (DTA&TG). The samples were studied by X-ray diffraction (XRD) analysis. Electrical conductivity of La 0.9 Mg 0.1 OCl 0.1 was measured using electrical impedance spectroscopy (EIS). The prototype chlorine gas sensor was constructed from La 0.9 Mg 0.1 OCl 0.1 solid electrolyte. The source voltage (SV) of the constructed device was measured as a function of temperature (500–800°C), Cl 2 gradient partial pressure and time. Similar measurements of SV was carried out in atmosphere of synthetic air in argon.

Referência(s)
Altmetric
PlumX